Li An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Li An has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Jun Shen
Section on Magnetic Resonance Spectroscopy National Institute of Mental Health, National Institutes of Health Bethesda Maryland USA
20 shared publicationsMaria Ferraris Araneta
Molecular Imaging Branch National Institute of Mental Health National Institutes of Health Building 10 Room 3D46 10 Center Drive MSC 1216 20892-1216 Bethesda Bethesda MD MD
9 shared publicationsShizhe Li
Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, USA
6 shared publicationsChristopher S. Johnson
National Institute of Mental Health National Institutes of Health Bethesda Maryland USA
5 shared publications- Sungtak Hong
Section on Magnetic Resonance Spectroscopy National Institute of Mental Health, National Institutes of Health Bethesda Maryland USA
5 shared publications Christopher Johnson
National Institutes of Health
4 shared publications
Latest Publications
- Open Access
- 23 November 2026
- Published by Wiley in Magnetic Resonance in Medicine
Spectral Decorrelation of Glutamate for Clinical Proton Magnetic Resonance Spectroscopy
Purpose: Although glutamate (Glu) plays a central role in many neuropsychiatric disorders, MRS measurement of Glu often suffers from confounding correlations due to spectral overlap, adversely affecting subsequent clinical correlational analysis. This study aimed to optimize the commonly used 3 T PRESS method to minimize the overall Glu spectral correlation with other neurometabolites. Methods: Monte Carlo simulations combined with a mathematical model of spectral fitting were used to evaluate spectral correlations between Glu and other metabolites. The optimal {TE1, TE} pair minimizing the overall Glu correlation was identified and validated by analyzing in vivo measurement of Glu in the anterior cingulate cortex. The robustness of the optimization was further assessed under varying spectral linewidths and altered metabolite concentrations. Results: The optimal {TE1, TE} values for 4, 6, 8, and 10 Hz linewidth were found to be {42, 100}, {40, 95}, {38, 94}, and {38, 90} ms, respectively. These optimal {TE1, TE} pairs reduced the overall Glu spectral correlation coefficient to less than 0.05, corresponding to a negligible effect size. This reduction was consistently observed in both Monte Carlo simulations and analysis of in vivo measurements and remained robust across metabolite level variations typically seen in bipolar disorder, methamphetamine use disorder, obsessive‐compulsive disorder, and hepatic encephalopathy. Conclusion: Systematic optimization of the {TE1, TE} pair enables decorrelation of Glu MRS measurement at 3 Tesla by effectively minimizing confounding spectral correlations among brain metabolites. The proposed approach provides a robust and clinically applicable framework that decorrelates Glu MRS measurements for viable downstream clinical analyses.
- 23 November 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessSpectral Decorrelation of Glutamate for Clinical Proton Magnetic Resonance Spectroscopy
Purpose: Although glutamate (Glu) plays a central role in many neuropsychiatric disorders, MRS measurement of Glu often suffers from confounding correlations due to spectral overlap, adversely affecting subsequent clinical correlational analysis. This study aimed to optimize the commonly used 3 T PRESS method to minimize the overall Glu spectral correlation with other neurometabolites. Methods: Monte Carlo simulations combined with a mathematical model of spectral fitting were used to evaluate spectral correlations between Glu and other metabolites. The optimal {TE1, TE} pair minimizing the overall Glu correlation was identified and validated by analyzing in vivo measurement of Glu in the anterior cingulate cortex. The robustness of the optimization was further assessed under varying spectral linewidths and altered metabolite concentrations. Results: The optimal {TE1, TE} values for 4, 6, 8, and 10 Hz linewidth were found to be {42, 100}, {40, 95}, {38, 94}, and {38, 90} ms, respectively. These optimal {TE1, TE} pairs reduced the overall Glu spectral correlation coefficient to less than 0.05, corresponding to a negligible effect size. This reduction was consistently observed in both Monte Carlo simulations and analysis of in vivo measurements and remained robust across metabolite level variations typically seen in bipolar disorder, methamphetamine use disorder, obsessive‐compulsive disorder, and hepatic encephalopathy. Conclusion: Systematic optimization of the {TE1, TE} pair enables decorrelation of Glu MRS measurement at 3 Tesla by effectively minimizing confounding spectral correlations among brain metabolites. The proposed approach provides a robust and clinically applicable framework that decorrelates Glu MRS measurements for viable downstream clinical analyses.
- Open Access
- 8 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 668-679
Simultaneous in vivo detection of spectrally resolved glutamate, glutamine, and glutathione at 3 T with NAA ‐aspartyl editing and echo‐time optimization
Purpose: To achieve spectrally resolved in vivo detection of glutamate, glutamine, and glutathione at 3 T. Methods: Difference editing of N‐acetylaspartate CH 2 protons (NAA‐CH 2 ) combined with a new echo‐time (TE) optimization approach is introduced. Difference editing was used to detect NAA‐CH 2 independently of NAA‐CH 3 , thereby eliminating systematic errors arising from constrained fitting of the entire NAA molecule. Numerical optimization of TE and TE 1 minimized interference from highly dominant glutamate in glutamine detection in the ON/OFF sum spectrum. In vivo data were acquired from 6 healthy participants, including 2 who underwent oral administration of [U‐ 13 C]glucose. Results: The NAA‐aspartyl‐edited, cleaned‐up in vivo spectrum showed distinct separation of glutamate, glutamine, and glutathione peaks at 3 T, facilitating spectral quantification and clinical applications. The post‐ 13 C proton MR‐spectroscopy spectra clearly demonstrated the dynamic 13 C‐labeling of glutamate C4 following oral [U‐ 13 C]glucose intake. Conclusion: This technique enables simultaneous spectral resolution of glutamate, glutamine, and glutathione peaks at 3 T using difference editing of NAA‐CH 2 and an optimized TE of 85 ms. Additionally, it demonstrates, for the first time, the feasibility of measuring 13 C turnovers of spectrally resolved glutamate at 3 T with the high sensitivity and spatial resolution of proton MR spectroscopy.
- 8 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 668-679
Open AccessSimultaneous in vivo detection of spectrally resolved glutamate, glutamine, and glutathione at 3 T with NAA ‐aspartyl editing and echo‐time optimization
Purpose: To achieve spectrally resolved in vivo detection of glutamate, glutamine, and glutathione at 3 T. Methods: Difference editing of N‐acetylaspartate CH 2 protons (NAA‐CH 2 ) combined with a new echo‐time (TE) optimization approach is introduced. Difference editing was used to detect NAA‐CH 2 independently of NAA‐CH 3 , thereby eliminating systematic errors arising from constrained fitting of the entire NAA molecule. Numerical optimization of TE and TE 1 minimized interference from highly dominant glutamate in glutamine detection in the ON/OFF sum spectrum. In vivo data were acquired from 6 healthy participants, including 2 who underwent oral administration of [U‐ 13 C]glucose. Results: The NAA‐aspartyl‐edited, cleaned‐up in vivo spectrum showed distinct separation of glutamate, glutamine, and glutathione peaks at 3 T, facilitating spectral quantification and clinical applications. The post‐ 13 C proton MR‐spectroscopy spectra clearly demonstrated the dynamic 13 C‐labeling of glutamate C4 following oral [U‐ 13 C]glucose intake. Conclusion: This technique enables simultaneous spectral resolution of glutamate, glutamine, and glutathione peaks at 3 T using difference editing of NAA‐CH 2 and an optimized TE of 85 ms. Additionally, it demonstrates, for the first time, the feasibility of measuring 13 C turnovers of spectrally resolved glutamate at 3 T with the high sensitivity and spatial resolution of proton MR spectroscopy.
- Open Access
- 20 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2278-2286
Enhanced detection of glutamate via transverse relaxation encoding with narrowband decoupling in the human brain
Purpose: This study aims to improve the detection of glutamate (Glu) concentration and T 2 using an enhanced transverse relaxation encoding with narrowband decoupling (TREND) technique. Methods: A new editing pulse was designed to simultaneously invert both Glu H3 spins (2.12 ppm and 2.05 ppm) while minimizing the excitation of Glu H4. Additionally, a frequency band was created to invert the lactate (Lac) H2 spin (4.10 ppm) while saturating the NAA aspartyl H2 spin (4.38 ppm). Numerical simulations compared Glu and Lac signals using the original and new editing pulses. In vivo experiments were conducted on healthy participants at 7 T to validate this enhanced TREND technique. Results: Numerical simulations showed prominently enhanced Glu and Lac resonance signals with the new editing pulse. In vivo spectra showed a 47% ± 14% increase in Glu/Cr peak amplitude ratios with the new editing pulse. Using the enhanced TREND sequence, Glu/Cr concentration ratios in the anterior cingulate cortex were 1.03 ± 0.07 with Cramer‐Rao lower bounds (CRLBs) of 1.1% ± 0.1%, and Glu T 2 values were 179 ± 18 ms with CRLBs of 1.2% ± 0.1%. The Lac/Cr concentration ratios in the same voxels were 0.05 ± 0.01 with CRLBs of 26% ± 14%, and Lac T 2 values were 196 ± 23 ms with CRLBs of 22% ± 15%. Conclusion: The new editing pulse significantly enhanced the detection of Glu and enabled the detection of Lac using TREND for measuring both the concentration and T 2 of the markers of oxidative metabolism and glycolysis.
- 20 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2278-2286
Open AccessEnhanced detection of glutamate via transverse relaxation encoding with narrowband decoupling in the human brain
Purpose: This study aims to improve the detection of glutamate (Glu) concentration and T 2 using an enhanced transverse relaxation encoding with narrowband decoupling (TREND) technique. Methods: A new editing pulse was designed to simultaneously invert both Glu H3 spins (2.12 ppm and 2.05 ppm) while minimizing the excitation of Glu H4. Additionally, a frequency band was created to invert the lactate (Lac) H2 spin (4.10 ppm) while saturating the NAA aspartyl H2 spin (4.38 ppm). Numerical simulations compared Glu and Lac signals using the original and new editing pulses. In vivo experiments were conducted on healthy participants at 7 T to validate this enhanced TREND technique. Results: Numerical simulations showed prominently enhanced Glu and Lac resonance signals with the new editing pulse. In vivo spectra showed a 47% ± 14% increase in Glu/Cr peak amplitude ratios with the new editing pulse. Using the enhanced TREND sequence, Glu/Cr concentration ratios in the anterior cingulate cortex were 1.03 ± 0.07 with Cramer‐Rao lower bounds (CRLBs) of 1.1% ± 0.1%, and Glu T 2 values were 179 ± 18 ms with CRLBs of 1.2% ± 0.1%. The Lac/Cr concentration ratios in the same voxels were 0.05 ± 0.01 with CRLBs of 26% ± 14%, and Lac T 2 values were 196 ± 23 ms with CRLBs of 22% ± 15%. Conclusion: The new editing pulse significantly enhanced the detection of Glu and enabled the detection of Lac using TREND for measuring both the concentration and T 2 of the markers of oxidative metabolism and glycolysis.
- Open Access
- 9 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 4-14
In vivo GABA detection by single‐pulse editing with one shot
Purpose: Two‐shot γ‐aminobutyric acid (GABA) difference editing techniques have been used widely to detect the GABA H4 resonance at 3.01 ppm. Here, we introduce a single‐shot method for detecting the full GABA H2 resonance signal, which avoids contamination from the coedited M 3.00 macromolecules. Methods: Density matrix simulation was conducted to optimize the pulse‐sequence timing, aiming to reduce the interfering glutamate H4 signal and minimize the correlation between glutamate and GABA arising from spectral overlap. The optimized sequence was used to acquire MR spectroscopy data from a 14‐mL voxel in the anterior cingulate cortex of 6 healthy participants. 1 H–MRS experiments following the oral administration of [U‐ 13 C]glucose were also conducted. Results: The GABA H2 peak was consistently observed in all participants. The GABA/creatine ratios in the participants were determined to be 0.07 ± 0.01 with Cramer‐Rao lower bounds of 8.0% ± 2.2%. Spectra acquired following [U‐ 13 C]glucose intake demonstrated the feasibility of using GABA H2 as a highly sensitive reporter for GABA C2. Conclusion: The proposed single‐shot GABA editing method effectively minimizes interference from the glutamate H4 signal in the detection of the full GABA H2 signal, which resonates at a spectral region with much reduced macromolecule contamination.
- 9 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 4-14
Open AccessIn vivo GABA detection by single‐pulse editing with one shot
Purpose: Two‐shot γ‐aminobutyric acid (GABA) difference editing techniques have been used widely to detect the GABA H4 resonance at 3.01 ppm. Here, we introduce a single‐shot method for detecting the full GABA H2 resonance signal, which avoids contamination from the coedited M 3.00 macromolecules. Methods: Density matrix simulation was conducted to optimize the pulse‐sequence timing, aiming to reduce the interfering glutamate H4 signal and minimize the correlation between glutamate and GABA arising from spectral overlap. The optimized sequence was used to acquire MR spectroscopy data from a 14‐mL voxel in the anterior cingulate cortex of 6 healthy participants. 1 H–MRS experiments following the oral administration of [U‐ 13 C]glucose were also conducted. Results: The GABA H2 peak was consistently observed in all participants. The GABA/creatine ratios in the participants were determined to be 0.07 ± 0.01 with Cramer‐Rao lower bounds of 8.0% ± 2.2%. Spectra acquired following [U‐ 13 C]glucose intake demonstrated the feasibility of using GABA H2 as a highly sensitive reporter for GABA C2. Conclusion: The proposed single‐shot GABA editing method effectively minimizes interference from the glutamate H4 signal in the detection of the full GABA H2 signal, which resonates at a spectral region with much reduced macromolecule contamination.
- Open Access
In Vivo GABA Detection by Single Pulse Editing with One Shot
Over the past two decades, magnetic resonance spectroscopy with two-shot difference editing has been widely employed to characterize altered levels of GABA, the primary inhibitory neurotransmitter in the brain, in various neuropsychiatric disorders. This conventional technique detects the GABA H4 resonance, making it unsuitable for investigating GABA metabolism. It also suffers from subtraction artifacts, signal loss, and significant contamination by macromolecules. Here, we introduce a single-shot method for detecting GABA H2, effectively overcoming these difficulties. Since GABA turnover initiates at its protonated C2 and unprotonated C1 positions, we demonstrate, for the first time, noninvasive real-time monitoring of GABA metabolism in the human brain, utilizing GABA H2 as a highly sensitive reporter for GABA C2. This new method not only enhances the quantitative measurement of GABA levels but also opens up a new avenue to probe the metabolic processes underlying alterations in GABA levels in patients.
Open AccessIn Vivo GABA Detection by Single Pulse Editing with One Shot
Over the past two decades, magnetic resonance spectroscopy with two-shot difference editing has been widely employed to characterize altered levels of GABA, the primary inhibitory neurotransmitter in the brain, in various neuropsychiatric disorders. This conventional technique detects the GABA H4 resonance, making it unsuitable for investigating GABA metabolism. It also suffers from subtraction artifacts, signal loss, and significant contamination by macromolecules. Here, we introduce a single-shot method for detecting GABA H2, effectively overcoming these difficulties. Since GABA turnover initiates at its protonated C2 and unprotonated C1 positions, we demonstrate, for the first time, noninvasive real-time monitoring of GABA metabolism in the human brain, utilizing GABA H2 as a highly sensitive reporter for GABA C2. This new method not only enhances the quantitative measurement of GABA levels but also opens up a new avenue to probe the metabolic processes underlying alterations in GABA levels in patients.
- Open Access
- 27 July 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
In vivo magnetic resonance spectroscopy by transverse relaxation encoding with narrowband decoupling
Cell pathology in neuropsychiatric disorders has mainly been accessible by analyzing postmortem tissue samples. Although molecular transverse relaxation informs local cellular microenvironment via molecule-environment interactions, precise determination of the transverse relaxation times of molecules with scalar couplings (J), such as glutamate and glutamine, has been difficult using in vivo magnetic resonance spectroscopy (MRS) technologies, whose approach to measuring transverse relaxation has not changed for decades. We introduce an in vivo MRS technique that utilizes frequency-selective editing pulses to achieve homonuclear decoupled chemical shift encoding in each column of the acquired two-dimensional dataset, freeing up the entire row dimension for transverse relaxation encoding with J-refocusing. This results in increased spectral resolution, minimized background signals, and markedly broadened dynamic range for transverse relaxation encoding. The in vivo within-subject coefficients of variation for the transverse relaxation times of glutamate and glutamine, measured using the proposed method in the human brain at 7 T, were found to be approximately 4%. Since glutamate predominantly resides in glutamatergic neurons and glutamine in glia in the brain, this noninvasive technique provides a way to probe cellular pathophysiology in neuropsychiatric disorders for characterizing disease progression and monitoring treatment response in a cell type-specific manner in vivo.
- 27 July 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
Open AccessIn vivo magnetic resonance spectroscopy by transverse relaxation encoding with narrowband decoupling
Cell pathology in neuropsychiatric disorders has mainly been accessible by analyzing postmortem tissue samples. Although molecular transverse relaxation informs local cellular microenvironment via molecule-environment interactions, precise determination of the transverse relaxation times of molecules with scalar couplings (J), such as glutamate and glutamine, has been difficult using in vivo magnetic resonance spectroscopy (MRS) technologies, whose approach to measuring transverse relaxation has not changed for decades. We introduce an in vivo MRS technique that utilizes frequency-selective editing pulses to achieve homonuclear decoupled chemical shift encoding in each column of the acquired two-dimensional dataset, freeing up the entire row dimension for transverse relaxation encoding with J-refocusing. This results in increased spectral resolution, minimized background signals, and markedly broadened dynamic range for transverse relaxation encoding. The in vivo within-subject coefficients of variation for the transverse relaxation times of glutamate and glutamine, measured using the proposed method in the human brain at 7 T, were found to be approximately 4%. Since glutamate predominantly resides in glutamatergic neurons and glutamine in glia in the brain, this noninvasive technique provides a way to probe cellular pathophysiology in neuropsychiatric disorders for characterizing disease progression and monitoring treatment response in a cell type-specific manner in vivo.
- Open Access
- 24 March 2023
In Vivo Magnetic Resonance Spectroscopy by J-Locked Chemical Shift Encoding for Determination of Neurochemical Concentration and Transverse Relaxation Time.
Cell pathology in neuropsychiatric disorders has mainly been accessible by analyzing postmortem tissue samples. Although molecular transverse relaxation informs local cellular microenvironment via molecule-environment interactions, precise determination of the transverse relaxation times of molecules with scalar couplings (J), such as glutamate and glutamine, is difficult using current in vivo magnetic resonance spectroscopy (MRS) technologies, whose approach to measuring transverse relaxation has not changed for decades. We introduce an in vivo MRS technique that achieves chemical shift encoding with selectively locked J-couplings in each column of the acquired two-dimensional dataset, freeing up the entire row dimension for transverse relaxation encoding. This results in increased spectral resolution, minimized background signals, and markedly broadened dynamic range for transverse relaxation encoding. This technique enables determination of the transverse relaxation times of glutamate and glutamine in vivo with unprecedented high precision. Since glutamate predominantly resides in glutamatergic neurons and glutamine in glia in the brain, this noninvasive technique provides a way to probe cellular pathophysiology in neuropsychiatric disorders for characterizing disease progression and monitoring treatment response in a cell type-specific manner in vivo.
- 24 March 2023
Open AccessIn Vivo Magnetic Resonance Spectroscopy by J-Locked Chemical Shift Encoding for Determination of Neurochemical Concentration and Transverse Relaxation Time.
Cell pathology in neuropsychiatric disorders has mainly been accessible by analyzing postmortem tissue samples. Although molecular transverse relaxation informs local cellular microenvironment via molecule-environment interactions, precise determination of the transverse relaxation times of molecules with scalar couplings (J), such as glutamate and glutamine, is difficult using current in vivo magnetic resonance spectroscopy (MRS) technologies, whose approach to measuring transverse relaxation has not changed for decades. We introduce an in vivo MRS technique that achieves chemical shift encoding with selectively locked J-couplings in each column of the acquired two-dimensional dataset, freeing up the entire row dimension for transverse relaxation encoding. This results in increased spectral resolution, minimized background signals, and markedly broadened dynamic range for transverse relaxation encoding. This technique enables determination of the transverse relaxation times of glutamate and glutamine in vivo with unprecedented high precision. Since glutamate predominantly resides in glutamatergic neurons and glutamine in glia in the brain, this noninvasive technique provides a way to probe cellular pathophysiology in neuropsychiatric disorders for characterizing disease progression and monitoring treatment response in a cell type-specific manner in vivo.
- Open Access
In Vivo Magnetic Resonance Spectroscopy by J-Locked Chemical Shift Encoding for Determination of Neurochemical Concentration and Transverse Relaxation Time
Cell pathology in neuropsychiatric disorders has mainly been accessible by analyzing postmortem tissue samples. Although molecular transverse relaxation informs local cellular microenvironment via molecule-environment interactions, precise determination of the transverse relaxation times of molecules with scalar couplings (J), such as glutamate and glutamine, is difficult using current in vivo magnetic resonance spectroscopy (MRS) technologies, whose approach to measuring transverse relaxation has not changed for decades. We introduce an in vivo MRS technique that achieves chemical shift encoding with selectively locked J-couplings in each column of the acquired two-dimensional dataset, freeing up the entire row dimension for transverse relaxation encoding. This results in increased spectral resolution, minimized background signals, and markedly broadened dynamic range for transverse relaxation encoding. This technique enables determination of the transverse relaxation times of glutamate and glutamine in vivo with unprecedented high precision. Since glutamate predominantly resides in glutamatergic neurons and glutamine in glia in the brain, this noninvasive technique provides a way to probe cellular pathophysiology in neuropsychiatric disorders for characterizing disease progression and monitoring treatment response in a cell type-specific manner in vivo.
Open AccessIn Vivo Magnetic Resonance Spectroscopy by J-Locked Chemical Shift Encoding for Determination of Neurochemical Concentration and Transverse Relaxation Time
Cell pathology in neuropsychiatric disorders has mainly been accessible by analyzing postmortem tissue samples. Although molecular transverse relaxation informs local cellular microenvironment via molecule-environment interactions, precise determination of the transverse relaxation times of molecules with scalar couplings (J), such as glutamate and glutamine, is difficult using current in vivo magnetic resonance spectroscopy (MRS) technologies, whose approach to measuring transverse relaxation has not changed for decades. We introduce an in vivo MRS technique that achieves chemical shift encoding with selectively locked J-couplings in each column of the acquired two-dimensional dataset, freeing up the entire row dimension for transverse relaxation encoding. This results in increased spectral resolution, minimized background signals, and markedly broadened dynamic range for transverse relaxation encoding. This technique enables determination of the transverse relaxation times of glutamate and glutamine in vivo with unprecedented high precision. Since glutamate predominantly resides in glutamatergic neurons and glutamine in glia in the brain, this noninvasive technique provides a way to probe cellular pathophysiology in neuropsychiatric disorders for characterizing disease progression and monitoring treatment response in a cell type-specific manner in vivo.
- Open Access
- 14 June 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Roles of Strong Scalar Couplings in Maximizing Glutamate, Glutamine and Glutathione Pseudo Singlets at 7 Tesla
For the H4 protons of glutamate (Glu), glutamine (Gln), and the glutamyl moiety of glutathione (GSH), the effect of the internal strong scalar coupling between the two nonequivalent H4 protons is far greater than that of the external couplings between the H3 and H4 protons. In this work, the roles of the internal and external scalar coupling terms in the dependence of Glu, Gln, and glutamyl GSH H4 peak amplitudes on the placement of the refocusing pulses of the point resolved spectroscopy sequence were investigated by full density matrix simulations. These strong coupling effects allowed practical and approximately simultaneous maximization of the sensitivity of the spectrally resolved Glu, Gln, and glutamyl GSH H4 pseudo singlets for spatially localized in vivo detection of Glu, Gln, and GSH in the human brain using magnetic resonance spectroscopy at the magnetic field strength of 7 Tesla.
- 14 June 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessRoles of Strong Scalar Couplings in Maximizing Glutamate, Glutamine and Glutathione Pseudo Singlets at 7 Tesla
For the H4 protons of glutamate (Glu), glutamine (Gln), and the glutamyl moiety of glutathione (GSH), the effect of the internal strong scalar coupling between the two nonequivalent H4 protons is far greater than that of the external couplings between the H3 and H4 protons. In this work, the roles of the internal and external scalar coupling terms in the dependence of Glu, Gln, and glutamyl GSH H4 peak amplitudes on the placement of the refocusing pulses of the point resolved spectroscopy sequence were investigated by full density matrix simulations. These strong coupling effects allowed practical and approximately simultaneous maximization of the sensitivity of the spectrally resolved Glu, Gln, and glutamyl GSH H4 pseudo singlets for spatially localized in vivo detection of Glu, Gln, and GSH in the human brain using magnetic resonance spectroscopy at the magnetic field strength of 7 Tesla.
- 14 June 2022
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 341, 107257
Monte Carlo study of metabolite correlations originating from spectral overlap
- 14 June 2022
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 341, 107257
Monte Carlo study of metabolite correlations originating from spectral overlap