Spectral Decorrelation of Glutamate for Clinical Proton Magnetic Resonance Spectroscopy
Open Access
- 23 November 2026
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
Abstract
Purpose: Although glutamate (Glu) plays a central role in many neuropsychiatric disorders, MRS measurement of Glu often suffers from confounding correlations due to spectral overlap, adversely affecting subsequent clinical correlational analysis. This study aimed to optimize the commonly used 3 T PRESS method to minimize the overall Glu spectral correlation with other neurometabolites. Methods: Monte Carlo simulations combined with a mathematical model of spectral fitting were used to evaluate spectral correlations between Glu and other metabolites. The optimal {TE1, TE} pair minimizing the overall Glu correlation was identified and validated by analyzing in vivo measurement of Glu in the anterior cingulate cortex. The robustness of the optimization was further assessed under varying spectral linewidths and altered metabolite concentrations. Results: The optimal {TE1, TE} values for 4, 6, 8, and 10 Hz linewidth were found to be {42, 100}, {40, 95}, {38, 94}, and {38, 90} ms, respectively. These optimal {TE1, TE} pairs reduced the overall Glu spectral correlation coefficient to less than 0.05, corresponding to a negligible effect size. This reduction was consistently observed in both Monte Carlo simulations and analysis of in vivo measurements and remained robust across metabolite level variations typically seen in bipolar disorder, methamphetamine use disorder, obsessive‐compulsive disorder, and hepatic encephalopathy. Conclusion: Systematic optimization of the {TE1, TE} pair enables decorrelation of Glu MRS measurement at 3 Tesla by effectively minimizing confounding spectral correlations among brain metabolites. The proposed approach provides a robust and clinically applicable framework that decorrelates Glu MRS measurements for viable downstream clinical analyses.Funding Information
- National Institutes of Health (ZIA MH002803)
This publication has 41 references indexed in Scilit:
- Simultaneous Measurement of GABA, Glutathione, and Glutamate–Glutamine in the Thalamus using Edited MR Spectroscopy: Feasibility and Applications in Traumatic Brain InjuryJournal of Magnetic Resonance Imaging, 2024
- In Vivo NMR Spectroscopy2018
- Fast computation of full density matrix of multispin systems for spatially localizedin vivomagnetic resonance spectroscopyMedical Physics, 2017
- Effect of repetition time on metabolite quantification in the human brain in 1H MR spectroscopy at 3 teslaJournal of Magnetic Resonance Imaging, 2016
- Study of the features of proton MR spectroscopy (1H‐MRS) on amyotrophic lateral sclerosisJournal of Magnetic Resonance Imaging, 2010
- Measurement of brain glutamate using TE‐averaged PRESS at 3TMagnetic Resonance in Medicine, 2004
- Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 TeslaMagnetic Resonance in Medicine, 2003
- Proton Magnetic Resonance Spectroscopy of the Primary Motor Cortex in Patients With Motor Neuron DiseaseArchives of Neurology, 1998
- Spectroscopic imaging of human brain glutamate by water‐suppressed J‐refocused coherence transfer at 4.1 TMagnetic Resonance in Medicine, 1996
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993