Filipe M. M. Marreiros
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Filipe M. M. Marreiros has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Chunliang Wang
Center for Medical Image Science and Visualization (CMIV), Linköping University, Sweden
1 shared publication- Claudia Unterhofer
Department of Neurosurgery, Medical University of Innsbruck, Innsbruck, Austria
1 shared publication - Michael Verius
Department of Radiology, Medical University Innsbruck, Innsbruck, Austria
1 shared publication Sandro Rossitti
Department of Neurosurgery, County Council of Ostergötland, Linköping, Sweden
1 shared publication- Wolfgang Freysinger
Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, 6020 Innsbruck, Austria
1 shared publication - Wolfgang Recheis
University Hospital of Radiology, Medical University Innsbruck, Innsbruck, Austria
1 shared publication
Latest Publications
- 29 June 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (12) , 2217-2230
Custom implant design for large cranial defects
Purpose The aim of this work was to introduce a computer-aided design (CAD) tool that enables the design of large skull defect (>100 \(\mathrm{cm}^2\)) implants. Functional and aesthetically correct custom implants are extremely important for patients with large cranial defects. For these cases, preoperative fabrication of implants is recommended to avoid problems of donor site morbidity, sufficiency of donor material and quality. Finally, crafting the correct shape is a non-trivial task increasingly complicated by defect size. Methods We present a CAD tool to design such implants for the neurocranium. A combination of geometric morphometrics and radial basis functions, namely thin-plate splines, allows semiautomatic implant generation. The method uses symmetry and the best fitting shape to estimate missing data directly within the radiologic volume data. In addition, this approach delivers correct implant fitting via a boundary fitting approach. Results This method generates a smooth implant surface, free of sharp edges that follows the main contours of the boundary, enabling accurate implant placement in the defect site intraoperatively. The present approach is evaluated and compared to existing methods. A mean error of 89.29 % (72.64–100 %) missing landmarks with an error less or equal to 1 mm was obtained. Conclusion In conclusion, the results show that our CAD tool can generate patient-specific implants with high accuracy.- 29 June 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (12) , 2217-2230
Custom implant design for large cranial defects
Purpose The aim of this work was to introduce a computer-aided design (CAD) tool that enables the design of large skull defect (>100 \(\mathrm{cm}^2\)) implants. Functional and aesthetically correct custom implants are extremely important for patients with large cranial defects. For these cases, preoperative fabrication of implants is recommended to avoid problems of donor site morbidity, sufficiency of donor material and quality. Finally, crafting the correct shape is a non-trivial task increasingly complicated by defect size. Methods We present a CAD tool to design such implants for the neurocranium. A combination of geometric morphometrics and radial basis functions, namely thin-plate splines, allows semiautomatic implant generation. The method uses symmetry and the best fitting shape to estimate missing data directly within the radiologic volume data. In addition, this approach delivers correct implant fitting via a boundary fitting approach. Results This method generates a smooth implant surface, free of sharp edges that follows the main contours of the boundary, enabling accurate implant placement in the defect site intraoperatively. The present approach is evaluated and compared to existing methods. A mean error of 89.29 % (72.64–100 %) missing landmarks with an error less or equal to 1 mm was obtained. Conclusion In conclusion, the results show that our CAD tool can generate patient-specific implants with high accuracy.- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 16, 141-148
Non-rigid Deformation Pipeline for Compensation of Superficial Brain Shift
The correct visualization of anatomical structures is a critical component of neurosurgical navigation systems, to guide the surgeon to the areas of interest as well as to avoid brain damage. A major challenge for neuronavigation systems is the brain shift, or deformation of the exposed brain in comparison to preoperative Magnetic Resonance (MR) image sets. In this work paper, a non-rigid deformation pipeline is proposed for brain shift compensation of preoperative imaging datasets using superficial blood vessels as landmarks. The input was preoperative and intraoperative 3D image sets of superficial vessel centerlines. The intraoperative vessels (obtained using 3 Near-Infrared cameras) were registered and aligned with preoperative Magnetic Resonance Angiography vessel centerlines using manual interaction for the rigid transformation and, for the non-rigid transformation, the non-rigid point set registration method Coherent Point Drift. The rigid registration transforms the intraoperative points from the camera coordinate system to the preoperative MR coordinate system, and the non-rigid registration deals with local transformations in the MR coordinate system. Finally, the generation of a new deformed volume is achieved with the Thin-Plate Spline (TPS) method using as control points the matches in the MR coordinate system found in the previous step. The method was tested in a rabbit brain exposed via craniotomy, where deformations were produced by a balloon inserted into the brain. There was a good correlation between the real state of the brain and the deformed volume obtained using the pipeline. Maximum displacements were approximately 4.0 mm for the exposed brain alone, and 6.7 mm after balloon inflation.
- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 16, 141-148
Non-rigid Deformation Pipeline for Compensation of Superficial Brain Shift
The correct visualization of anatomical structures is a critical component of neurosurgical navigation systems, to guide the surgeon to the areas of interest as well as to avoid brain damage. A major challenge for neuronavigation systems is the brain shift, or deformation of the exposed brain in comparison to preoperative Magnetic Resonance (MR) image sets. In this work paper, a non-rigid deformation pipeline is proposed for brain shift compensation of preoperative imaging datasets using superficial blood vessels as landmarks. The input was preoperative and intraoperative 3D image sets of superficial vessel centerlines. The intraoperative vessels (obtained using 3 Near-Infrared cameras) were registered and aligned with preoperative Magnetic Resonance Angiography vessel centerlines using manual interaction for the rigid transformation and, for the non-rigid transformation, the non-rigid point set registration method Coherent Point Drift. The rigid registration transforms the intraoperative points from the camera coordinate system to the preoperative MR coordinate system, and the non-rigid registration deals with local transformations in the MR coordinate system. Finally, the generation of a new deformed volume is achieved with the Thin-Plate Spline (TPS) method using as control points the matches in the MR coordinate system found in the previous step. The method was tested in a rabbit brain exposed via craniotomy, where deformations were produced by a balloon inserted into the brain. There was a good correlation between the real state of the brain and the deformed volume obtained using the pipeline. Maximum displacements were approximately 4.0 mm for the exposed brain alone, and 6.7 mm after balloon inflation.