    Influence of lung injury on cardiac output measurement using transpulmonary ultrasound dilution: a validation study in neonatal lambs

    by S. L. Vrancken, W. P. de Boode, J. C. Hopman, M. G. Looijen-Salamon, K. D. Liem, A. F. van Heijst

    Transpulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in this population is high, which might influence CO measurement using TPUD because of altered lung perfusion. We evaluated the influence of lung injury on the accuracy and precision of CO measurement using TPUD in an animal model. In nine neonatal lambs, central venous and arterial catheters were inserted and connected to the TPUD monitor. Repeated lavages with warmed isotonic saline were performed to gradually induce lung injury. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe around the main pulmonary artery (COufp). An increase in oxygenation index was used as an indicator of induced lung injury during the experiment. Post-mortem lung injury was confirmed by histopathological examination. Fifty-five sessions of three paired CO measurements were analysed. The mean COufp was 1.53 litre min−1 (range 0.66–2.35 litre min−1), and the mean COtpud was 1.65 litre min−1 (range 0.78–2.91 litre min−1). The mean bias (standard deviation) between the two methods was 0.13 (0.15) litre min−1 with limits of agreement of ±0.29 litre min−1. The overall percentage error was 19.1%. The accuracy and precision did not change significantly during progressive lung injury. Histopathological severity scores were consistent with heterogeneous lung injury. The capability to track changes in CO using TPUD was moderate to good. The accuracy and precision of CO measurement using TPUD is not influenced in the presence of heterogeneous lung injury in an animal model.


  • Open Access

    Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs

    by S. L. Vrancken, W. P. de Boode, J. C. Hopman, S. K. Singh, K. D. Liem, A. F. van Heijst

    Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt. Regular arterial and central venous catheters were inserted into seven lambs (3.5–8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex® shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp). We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min−1 (range 0.47–1.75 litre min−1) and mean COtpud 1.05 litre min−1 (range 0.54–1.87 litre min−1). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3–2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min−1, respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups. TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.


  • Influence of Volume Replacement with Colloids versus Crystalloids in Neonates on Venoarterial Extracorporeal Membrane Oxygenation on Fluid Retention, Fluid Balance, and ECMO Runtime

    by Sabine L. Vrancken, Arno Fvan Heijst, Miranda Zegers, Frans Hvan der Staak, K Djien Liem, Arno F. van Heijst, Frans H. van der Staak

    In this retrospective study, we compared the effects of colloid versus crystalloid fluid replacement on the clinical signs of capillary leakage syndrome in 30 neonates with pulmonary hypertension due to meconium aspiration syndrome on venoarterial membrane oxygenation (VA-ECMO). Before 2000, 15 neonates received volume replacement with a pasteurized plasma protein solution (3.8% albumin); after 2000, 15 neonates received normal saline. Patient characteristics and pre-ECMO values did not differ between the two groups. Total fluid balance was also equal. Diuretic use was significantly higher in the colloid group (p < 0.001). The chest wall soft-tissue index was significantly higher in the crystalloid group (p < 0.005), as were the ventilator settings at the end of the ECMO runtime (p < 0.05). Serum colloid osmotic pressure, albumin, urea nitrogen, and creatinine were significantly higher in the colloid group (p < 0.0001, < 0.0001, < 0.001, and < 0.05, respectively). Duration of VA-ECMO, of artificial ventilation after ECMO treatment, and the mortality rate did not differ between the two groups. We conclude that volume replacement with crystalloids in neonates on VA-ECMO aggravated the edema in a preexisting situation of capillary leakage syndrome, whereas volume replacement with colloids could impair the kidney function.