Akira Kojima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Akira Kojima has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
H. Tobari
Japan Atomic Energy Agency, Naka, Ibaraki 311-0193, Japan
3 shared publicationsK. Watanabe
Japan Atomic Energy Agency, Naka, Ibaraki 311-0193, Japan
3 shared publicationsL. R. Grisham
Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
3 shared publicationsM. Hanada
Japan Atomic Energy Agency, Naka, Ibaraki 311-0193, Japan
3 shared publicationsM. Kashiwagi
Japan Atomic Energy Agency, Naka, Ibaraki 311-0193, Japan
3 shared publicationsN. Umeda
Japan Atomic Energy Agency, Naka, Ibaraki 311-0193, Japan
3 shared publications
Latest Publications
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 060009
Benchmark of 3D multi-beamlet numerical models for the optics design of negative ion accelerators
The optics design of the multi-beamlet negative ion accelerator for MITICA has been verified by means of specific experiments in the NITS test facility at the QST lab, employing a scaled-down configuration having the same features as the accelerator of MITICA and ITER HNB. The experiments confirmed the validity of the accelerator design. However it was found that, in the presence of transverse magnetic field in the ion extraction stage, the ion beamlet deflection in numerical simulations was somehow underestimated with respect to the beamlet deflection inferred from thermal images of a CFC target exposed to the negative ion beam. A detailed benchmark, using also another (completely independent) numerical model of the accelerator, has allowed the identification of possible origins of the differences.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 060009
Benchmark of 3D multi-beamlet numerical models for the optics design of negative ion accelerators
The optics design of the multi-beamlet negative ion accelerator for MITICA has been verified by means of specific experiments in the NITS test facility at the QST lab, employing a scaled-down configuration having the same features as the accelerator of MITICA and ITER HNB. The experiments confirmed the validity of the accelerator design. However it was found that, in the presence of transverse magnetic field in the ion extraction stage, the ion beamlet deflection in numerical simulations was somehow underestimated with respect to the beamlet deflection inferred from thermal images of a CFC target exposed to the negative ion beam. A detailed benchmark, using also another (completely independent) numerical model of the accelerator, has allowed the identification of possible origins of the differences.
- 5 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02B304
Development of design technique for vacuum insulation in large size multi-aperture multi-grid accelerator for nuclear fusion
Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltage holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.
- 5 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02B304
Development of design technique for vacuum insulation in large size multi-aperture multi-grid accelerator for nuclear fusion
Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltage holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.
- 11 February 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1515 (1) , 22
Study of negative hydrogen ion beam optics using the 2D PIC method
We have developed the integrated 2D PIC code for the analysis of the negative ion beam optics, in which an overall region from the source plasma to the accelerator is modeled. Thus, the negative ion trajectory can be solved self-consistently without any assumption of the plasma meniscus form initially. This code can reproduce the negative ion beam halo observed in an actual negative ion beam. It is confirmed that the surface produced negative ions which are extracted near the edge of the meniscus can be one of the reasons for the beam halo: these negative ions are over-focused due to the curvature of the meniscus. The negative ions are not focused by the electrostatic lens, and consequently become the beam halo.
- 11 February 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1515 (1) , 22
Study of negative hydrogen ion beam optics using the 2D PIC method
We have developed the integrated 2D PIC code for the analysis of the negative ion beam optics, in which an overall region from the source plasma to the accelerator is modeled. Thus, the negative ion trajectory can be solved self-consistently without any assumption of the plasma meniscus form initially. This code can reproduce the negative ion beam halo observed in an actual negative ion beam. It is confirmed that the surface produced negative ions which are extracted near the edge of the meniscus can be one of the reasons for the beam halo: these negative ions are over-focused due to the curvature of the meniscus. The negative ions are not focused by the electrostatic lens, and consequently become the beam halo.
- 11 February 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1515 (1) , 107
Study of plasma meniscus formation and beam halo in negative hydrogen ion sources
A meniscus of plasma-beam boundary in H− ion sources largely affects the extracted H− ion beam optics. Recently it is shown that the beam halo is mainly caused by the meniscus, i.e. ion emissive surface, close to the plasma grid (PG) where its curvature is large. The purpose of this study is to clarify the effect of H− surface production rate on plasma meniscus and beam halo formation with PIC (particle-in-cell) modeling. It is shown that the plasma meniscus and beam halo formation is strongly dependent on the amount of surface produced H− ions.
- 11 February 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1515 (1) , 107
Study of plasma meniscus formation and beam halo in negative hydrogen ion sources
A meniscus of plasma-beam boundary in H− ion sources largely affects the extracted H− ion beam optics. Recently it is shown that the beam halo is mainly caused by the meniscus, i.e. ion emissive surface, close to the plasma grid (PG) where its curvature is large. The purpose of this study is to clarify the effect of H− surface production rate on plasma meniscus and beam halo formation with PIC (particle-in-cell) modeling. It is shown that the plasma meniscus and beam halo formation is strongly dependent on the amount of surface produced H− ions.
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B117
Vacuum insulation of the high energy negative ion source for fusion application
Vacuum insulation on a large size negative ion accelerator with multiple extraction apertures and acceleration grids for fusion application was experimentally examined and designed. In the experiment, vacuum insulation characteristics were investigated in the JT-60 negative ion source with >1000 apertures on the grid with the surface area of ∼2 m2. The sustainable voltages varied with a square root of the gap lengths between the grids, and decreased with number of the apertures and with the surface area of the grids. Based on the obtained results, the JT-60SA (super advanced) negative ion source is designed to produce 22 A, 500 keV D− ion beams for 100 s.
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B117
Vacuum insulation of the high energy negative ion source for fusion application
Vacuum insulation on a large size negative ion accelerator with multiple extraction apertures and acceleration grids for fusion application was experimentally examined and designed. In the experiment, vacuum insulation characteristics were investigated in the JT-60 negative ion source with >1000 apertures on the grid with the surface area of ∼2 m2. The sustainable voltages varied with a square root of the gap lengths between the grids, and decreased with number of the apertures and with the surface area of the grids. Based on the obtained results, the JT-60SA (super advanced) negative ion source is designed to produce 22 A, 500 keV D− ion beams for 100 s.
- 1 February 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (2) , 02B112
Achievement and improvement of the JT-60U negative ion source for JT-60 Super Advanced (invited)
Developments of the large negative ion source have been progressed in the high-energy, high-power, and long-pulse neutral beam injector for JT-60 Super Advanced. Countermeasures have been studied and tested for critical issues of grid heat load and voltage holding capability. As for the heat load of the acceleration grids, direct interception of D− ions was reduced by adjusting the beamlet steering. As a result, the heat load was reduced below an allowable level for long-pulse injections. As for the voltage holding capability, local electric field was mitigated by tuning gap lengths between large-area acceleration grids in the accelerator. As a result, the voltage holding capability was improved up to the rated value of 500 kV. To investigate the voltage holding capability during beam acceleration, the beam acceleration test is ongoing with new extended gap.
- 1 February 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (2) , 02B112
Achievement and improvement of the JT-60U negative ion source for JT-60 Super Advanced (invited)
Developments of the large negative ion source have been progressed in the high-energy, high-power, and long-pulse neutral beam injector for JT-60 Super Advanced. Countermeasures have been studied and tested for critical issues of grid heat load and voltage holding capability. As for the heat load of the acceleration grids, direct interception of D− ions was reduced by adjusting the beamlet steering. As a result, the heat load was reduced below an allowable level for long-pulse injections. As for the voltage holding capability, local electric field was mitigated by tuning gap lengths between large-area acceleration grids in the accelerator. As a result, the voltage holding capability was improved up to the rated value of 500 kV. To investigate the voltage holding capability during beam acceleration, the beam acceleration test is ongoing with new extended gap.
- 11 September 2009
- Published by IOP Publishing in Nuclear Fusion
- Vol. 49 (11) , 115008
Fast dynamics of type I and grassy ELMs in JT-60U
In order to understand the physics of the ELM trigger and determine the ELM size, the fast ELM dynamics of type I and grassy ELMs have been studied in JT-60U, using new fast diagnostics with high spatial and temporal resolutions such as a lithium beam probe (Δt ∼ 0.5 ms) and a charge exchange recombination spectroscopy (Δt ∼ 2.5 ms), which can measure the electron density and the ion temperature, respectively. The evolution of the ion pressure profile in the pedestal region has been evaluated for the first time by detailed edge profile measurements. Then, the dynamics of the density, the ion temperature and the ion pressure in the ELM cycle has been investigated. The co-rotating plasmas are compared with the counter (ctr)-rotating plasmas for the understanding of the toroidal rotation effects. Type I ELMs observed in co-rotating plasmas exhibit a larger and wider ELM affected area (Δn ped/n ped ∼ 30%, radial extent >15 cm) than ctr-rotating plasmas (Δn ped/n ped ∼ 20%, radial extent ∼10 cm). Just before a type I ELM crash, the pedestal ion pressure and its maximum gradient in co-rotating plasmas are 20% and 12% higher than those in ctr-rotating plasmas, respectively. It is found that the radial extent of the ion pressure gradient at the pedestal region in co-rotating plasmas is 14% wider than that in ctr-rotating plasmas. The experimental results suggest that the ELM size is connected with the structure of the plasma pressure in the whole pedestal region. As for the dynamics of grassy ELMs, the collapse of density pedestal is smaller (<20%) and narrower (∼5 cm) than those of type I ELMs, as observed in the collapse of the electron temperature pedestal. Thus, it is confirmed that both conductive and convective losses due to grassy ELMs are small.
- 11 September 2009
- Published by IOP Publishing in Nuclear Fusion
- Vol. 49 (11) , 115008
Fast dynamics of type I and grassy ELMs in JT-60U
In order to understand the physics of the ELM trigger and determine the ELM size, the fast ELM dynamics of type I and grassy ELMs have been studied in JT-60U, using new fast diagnostics with high spatial and temporal resolutions such as a lithium beam probe (Δt ∼ 0.5 ms) and a charge exchange recombination spectroscopy (Δt ∼ 2.5 ms), which can measure the electron density and the ion temperature, respectively. The evolution of the ion pressure profile in the pedestal region has been evaluated for the first time by detailed edge profile measurements. Then, the dynamics of the density, the ion temperature and the ion pressure in the ELM cycle has been investigated. The co-rotating plasmas are compared with the counter (ctr)-rotating plasmas for the understanding of the toroidal rotation effects. Type I ELMs observed in co-rotating plasmas exhibit a larger and wider ELM affected area (Δn ped/n ped ∼ 30%, radial extent >15 cm) than ctr-rotating plasmas (Δn ped/n ped ∼ 20%, radial extent ∼10 cm). Just before a type I ELM crash, the pedestal ion pressure and its maximum gradient in co-rotating plasmas are 20% and 12% higher than those in ctr-rotating plasmas, respectively. It is found that the radial extent of the ion pressure gradient at the pedestal region in co-rotating plasmas is 14% wider than that in ctr-rotating plasmas. The experimental results suggest that the ELM size is connected with the structure of the plasma pressure in the whole pedestal region. As for the dynamics of grassy ELMs, the collapse of density pedestal is smaller (<20%) and narrower (∼5 cm) than those of type I ELMs, as observed in the collapse of the electron temperature pedestal. Thus, it is confirmed that both conductive and convective losses due to grassy ELMs are small.
- 1 February 2007
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 51 (2T) , 274-276
Observation of Radial Particle Transport Induced by the Fluctuation Measured with a Gold Neutral Beam Probe
The radial particle flux induced by the fluctuation is measured by a Gold Neutral Beam Probe. Then the transient transport phenomenon induced by the fluctuation is investigated in the tandem mirror GAMMA 10. When the drift wave is excited at the central cell, the density near the center is reduced and the divergence of the flux becomes similar to the time derivative of the electron density. It shows that the density reduction is caused by the flux induced by the drift wave. After the density reduction, the drift wave is saturated and comes to the steady state because the density reduction accompanies the reduction of density gradient. Therefore, the transport phenomenon accompanying the growth and saturation of the drift wave is observed experimentally. In the steady state, the phase difference obeys the boltzman relation including the electron non-adiabatic term.
- 1 February 2007
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 51 (2T) , 274-276
Observation of Radial Particle Transport Induced by the Fluctuation Measured with a Gold Neutral Beam Probe
The radial particle flux induced by the fluctuation is measured by a Gold Neutral Beam Probe. Then the transient transport phenomenon induced by the fluctuation is investigated in the tandem mirror GAMMA 10. When the drift wave is excited at the central cell, the density near the center is reduced and the divergence of the flux becomes similar to the time derivative of the electron density. It shows that the density reduction is caused by the flux induced by the drift wave. After the density reduction, the drift wave is saturated and comes to the steady state because the density reduction accompanies the reduction of density gradient. Therefore, the transport phenomenon accompanying the growth and saturation of the drift wave is observed experimentally. In the steady state, the phase difference obeys the boltzman relation including the electron non-adiabatic term.
- 1 June 1992
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 22 (3) , 185-193
Feasibility Study on Quality-of-life Questionnaires for Patients with Advanced Lung Cancer
In order to evaluate quality-of-life (QOL) questionnaires, we studied the reliability and validity of the self-rating forms: A, comprising 16 questions; B, comprising 39 questions (Table II and III), in a special study supported by the Ministry of Health and Welfare. Sixty-four patients with inoperable lung cancer and 50 patients with chronic, non-malignant disease were entered into the study. Form A was translated and modified to Japanese culture from Schipper's Functional Living Index-Cancer, and Form B was of our own design. The internal consistency of the forms was examined by Cronbach's alpha coefficient. Both forms except for aspects of physical and social concern on form B, had alpha values r0.05) except for social (forms A and B) and psychological (form B). Analysis of variance of the QOL scores revealed significantly lower scores for the cancer patients than for the non-malignant-disease patients, except for the social aspect of concern (P>0.001). Factor analysis, using the principal component method, identified four major factors to account for 60 and 42% of the total variance on forms A and B, respectively. The factors were: patient's mood, anxiety over disease and treatment, relationships with other people, physical capability. In conclusion, this has been the first feasible study to show that QOL forms from the West could be used in Japan with some modifications. We are at present studying successive changes in QOL for advanced lung cancer patients in clinical trials.
- 1 June 1992
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 22 (3) , 185-193
Feasibility Study on Quality-of-life Questionnaires for Patients with Advanced Lung Cancer
In order to evaluate quality-of-life (QOL) questionnaires, we studied the reliability and validity of the self-rating forms: A, comprising 16 questions; B, comprising 39 questions (Table II and III), in a special study supported by the Ministry of Health and Welfare. Sixty-four patients with inoperable lung cancer and 50 patients with chronic, non-malignant disease were entered into the study. Form A was translated and modified to Japanese culture from Schipper's Functional Living Index-Cancer, and Form B was of our own design. The internal consistency of the forms was examined by Cronbach's alpha coefficient. Both forms except for aspects of physical and social concern on form B, had alpha values r0.05) except for social (forms A and B) and psychological (form B). Analysis of variance of the QOL scores revealed significantly lower scores for the cancer patients than for the non-malignant-disease patients, except for the social aspect of concern (P>0.001). Factor analysis, using the principal component method, identified four major factors to account for 60 and 42% of the total variance on forms A and B, respectively. The factors were: patient's mood, anxiety over disease and treatment, relationships with other people, physical capability. In conclusion, this has been the first feasible study to show that QOL forms from the West could be used in Japan with some modifications. We are at present studying successive changes in QOL for advanced lung cancer patients in clinical trials.
- 1 October 1986
- Vol. 86 (10) , 1573-8
[A case of pigmentation of the oral mucosa by a silver endodontic cone].
- 1 October 1986
- Vol. 86 (10) , 1573-8
[A case of pigmentation of the oral mucosa by a silver endodontic cone].