David Fagnoul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Fagnoul has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Daniel De Backer
Department of Intensive Care, CHIREC Hospitals, Université Libre de Bruxelles, Brussels, Belgium.
7 shared publications - Jean-Louis Vincent
Department of Intensive Care, Erasme University Hospital, Université Libre de Bruxelles, Brussels, Belgium
4 shared publications Jean-Louis Vincent
2 shared publications- Alexandre Brasseur
Department of Intensive Care, CUB-Hôpital Erasme, Université Libre de Bruxelles, 1070 Brussels, Belgium
1 shared publication Antoine Herpain
1 shared publicationAsmae Belhaj
1 shared publication
Latest Publications
- Open Access
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 250
Effects of fluid administration on renal perfusion in critically ill patients
Introduction: Fluid administration is a first-line therapy for acute kidney injury associated with circulatory failure. Although aimed at increasing renal perfusion in these patients, this intervention may improve systemic hemodynamics without necessarily ameliorating intrarenal flow distribution or urine output. We used Doppler techniques to investigate the effects of fluid administration on intrarenal hemodynamics and the relationship between changes in renal hemodynamics and urine output. We hypothesized that, compared to systemic hemodynamic variables, changes in renal hemodynamics would better predict increase in urine output after fluid therapy. Methods: We measured systemic hemodynamic variables and performed renal interlobar artery Doppler on both kidneys before and after volume expansion in 49 adult patients with acute circulatory failure. We measured systolic and diastolic velocities and computed the resistivity index (RI). We recorded urine output for 3 h before and after the fluid challenge. Results: Fluid administration resulted in a small but consistent decrease in RI (from 0.73 ± 0.09 to 0.71 ± 0.09, p < 0.01). There was a concomitant increase in mean arterial pressure (from 75 ± 15 to 80 ± 14 mmHg, p < 0.01), pulse pressure (49 ± 19 to 55 ± 19 mmHg, p < 0.01) and urine output (55 ± 76 to 81 ± 87 ml/hour, p < 0.01). Changes in RI were negatively correlated with changes in urine output and mean arterial pressure but not in pulse pressure. The increase in urine output was predicted by changes in RI but not by changes in systemic hemodynamics. Conclusions: Changes in renal hemodynamics during a fluid challenge can be observed by Doppler ultrasonography before urine output increases. Moreover, these changes are better predictors of an increase in urine output than are mean arterial pressure and pulse pressure.
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 250
Open AccessEffects of fluid administration on renal perfusion in critically ill patients
Introduction: Fluid administration is a first-line therapy for acute kidney injury associated with circulatory failure. Although aimed at increasing renal perfusion in these patients, this intervention may improve systemic hemodynamics without necessarily ameliorating intrarenal flow distribution or urine output. We used Doppler techniques to investigate the effects of fluid administration on intrarenal hemodynamics and the relationship between changes in renal hemodynamics and urine output. We hypothesized that, compared to systemic hemodynamic variables, changes in renal hemodynamics would better predict increase in urine output after fluid therapy. Methods: We measured systemic hemodynamic variables and performed renal interlobar artery Doppler on both kidneys before and after volume expansion in 49 adult patients with acute circulatory failure. We measured systolic and diastolic velocities and computed the resistivity index (RI). We recorded urine output for 3 h before and after the fluid challenge. Results: Fluid administration resulted in a small but consistent decrease in RI (from 0.73 ± 0.09 to 0.71 ± 0.09, p < 0.01). There was a concomitant increase in mean arterial pressure (from 75 ± 15 to 80 ± 14 mmHg, p < 0.01), pulse pressure (49 ± 19 to 55 ± 19 mmHg, p < 0.01) and urine output (55 ± 76 to 81 ± 87 ml/hour, p < 0.01). Changes in RI were negatively correlated with changes in urine output and mean arterial pressure but not in pulse pressure. The increase in urine output was predicted by changes in RI but not by changes in systemic hemodynamics. Conclusions: Changes in renal hemodynamics during a fluid challenge can be observed by Doppler ultrasonography before urine output increases. Moreover, these changes are better predictors of an increase in urine output than are mean arterial pressure and pulse pressure.
- 1 November 2013
- Published by Elsevier in Resuscitation
- Vol. 84 (11) , 1519-1524
Extracorporeal life support associated with hypothermia and normoxemia in refractory cardiac arrest
- 1 November 2013
- Published by Elsevier in Resuscitation
- Vol. 84 (11) , 1519-1524
Extracorporeal life support associated with hypothermia and normoxemia in refractory cardiac arrest
- 1 June 2013
- Published by Wolters Kluwer Health in Current Opinion in Critical Care
- Vol. 19 (3) , 228-233
The role of invasive techniques in cardiopulmonary evaluation
To discuss the role of the invasive monitoring techniques pulmonary artery catheter (PAC) and transpulmonary thermodilution (TPD) for cardiopulmonary monitoring in the critically ill patient. Characterization of the nature of hemodynamic alterations and hemodynamic optimization can be achieved both with PAC and TPD. Some recent trials suggest that volumetric measurements may be preferred in conditions with preserved left ventricular systolic function, whereas pressure measurements should be preferred in patients with altered left ventricular systolic function. Extravascular lung water is strongly associated with outcome and may be used to reflect the impact of fluid management strategies. The time response of this measurement needs still to be better defined. This review highlights that PAC and TPD have an important role in cardiopulmonary monitoring of critically ill patients. Both techniques can be used efficiently to diagnose the nature of circulatory or respiratory failure and to monitor the effects of therapies. The choice of the technique should be guided by the patient's condition and the need for additional measurements rather than based on physician's preferences.
- 1 June 2013
- Published by Wolters Kluwer Health in Current Opinion in Critical Care
- Vol. 19 (3) , 228-233
The role of invasive techniques in cardiopulmonary evaluation
To discuss the role of the invasive monitoring techniques pulmonary artery catheter (PAC) and transpulmonary thermodilution (TPD) for cardiopulmonary monitoring in the critically ill patient. Characterization of the nature of hemodynamic alterations and hemodynamic optimization can be achieved both with PAC and TPD. Some recent trials suggest that volumetric measurements may be preferred in conditions with preserved left ventricular systolic function, whereas pressure measurements should be preferred in patients with altered left ventricular systolic function. Extravascular lung water is strongly associated with outcome and may be used to reflect the impact of fluid management strategies. The time response of this measurement needs still to be better defined. This review highlights that PAC and TPD have an important role in cardiopulmonary monitoring of critically ill patients. Both techniques can be used efficiently to diagnose the nature of circulatory or respiratory failure and to monitor the effects of therapies. The choice of the technique should be guided by the patient's condition and the need for additional measurements rather than based on physician's preferences.
- Open Access
- 1 January 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (1) , 409
Cerebral oximetry during extracorporeal cardiopulmonary resuscitation
- 1 January 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (1) , 409
Open AccessCerebral oximetry during extracorporeal cardiopulmonary resuscitation
- 1 December 2012
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 40, 1-328
275
- 1 December 2012
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 40, 1-328
105
Introduction: Sepsis-related ARDS is a life-threatening complication in critically ill patients. Endothelial cell activation and dysfunction have key roles in the pathophysiology of ARDS. Circulating endothelial cell (CEC) count as a marker of endothelial damage has been poorly studied in this setting. Hypothesis: CEC count may be elevated in patients with sepsis-related ARDS compared to those with severe sepsis or septic shock without respiratory failure. Methods: CEC enumeration was performed by indirect immunofluorescence using CD146-driven immunomagnetic isolation and a subsequent confirmatory step with Ulex-Europaeus-Lectin-1 staining according to a consensus isolation methodology. Arterial blood samples were drawn in 27 ARDS patients, 12 septic control patients, 13 non-septic control patients and12 healthy volunteers. Of the ARDS patients, 63% were graded as moderate or severe according to the recent Berlin definition. Demographic data, hemodynamic variables and prognostic variables (PaO2/FiO2 [P/F] ratio, 28-day survival, blood lactate, APACHE II and SOFA scores) were also recorded. Measurements were performed between 12-24 h after ICU admission and onset of sepsis.Median values (interquartile range) were compared using a Mann-Whitney test and correlations between CEC count and prognostic variables were analyzed. All tests were bidirectional and a p < 0.05 was considered significant. Results: The median CEC count in patients with moderate and severe ARDS was significantly higher compared to that in septic patients without ARDS [27.2 (17.9-49.4) cells/ml vs 17.1 (9.6-21.9) cells/ml, p< 0.01]. Patients with severe sepsis or septic shock had elevated CEC counts compared to non-septic patients [19.6 (14.2-30.6) cells/ml vs 10.8 (5.7-13.2) cells/ml, p<0.01]. In healthy volunteers, the CEC count was significantly lower than in critically ill patients [1.8 (0.4–3.7) cells/ml vs 17.9 (10.7-28.5) cells/ml, p<0.01]. None of the prognostic variables was significantly correlated with CEC count. Conclusions: CEC count is significantly higher in patients with moderate and severe ARDS than in non-ARDS septic and non-septic ICU patients. This finding highlights the importance of endothelial damage in ARDS.
- 1 December 2012
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 40, 1-328
105
Introduction: Sepsis-related ARDS is a life-threatening complication in critically ill patients. Endothelial cell activation and dysfunction have key roles in the pathophysiology of ARDS. Circulating endothelial cell (CEC) count as a marker of endothelial damage has been poorly studied in this setting. Hypothesis: CEC count may be elevated in patients with sepsis-related ARDS compared to those with severe sepsis or septic shock without respiratory failure. Methods: CEC enumeration was performed by indirect immunofluorescence using CD146-driven immunomagnetic isolation and a subsequent confirmatory step with Ulex-Europaeus-Lectin-1 staining according to a consensus isolation methodology. Arterial blood samples were drawn in 27 ARDS patients, 12 septic control patients, 13 non-septic control patients and12 healthy volunteers. Of the ARDS patients, 63% were graded as moderate or severe according to the recent Berlin definition. Demographic data, hemodynamic variables and prognostic variables (PaO2/FiO2 [P/F] ratio, 28-day survival, blood lactate, APACHE II and SOFA scores) were also recorded. Measurements were performed between 12-24 h after ICU admission and onset of sepsis.Median values (interquartile range) were compared using a Mann-Whitney test and correlations between CEC count and prognostic variables were analyzed. All tests were bidirectional and a p < 0.05 was considered significant. Results: The median CEC count in patients with moderate and severe ARDS was significantly higher compared to that in septic patients without ARDS [27.2 (17.9-49.4) cells/ml vs 17.1 (9.6-21.9) cells/ml, p< 0.01]. Patients with severe sepsis or septic shock had elevated CEC counts compared to non-septic patients [19.6 (14.2-30.6) cells/ml vs 10.8 (5.7-13.2) cells/ml, p<0.01]. In healthy volunteers, the CEC count was significantly lower than in critically ill patients [1.8 (0.4–3.7) cells/ml vs 17.9 (10.7-28.5) cells/ml, p<0.01]. None of the prognostic variables was significantly correlated with CEC count. Conclusions: CEC count is significantly higher in patients with moderate and severe ARDS than in non-ARDS septic and non-septic ICU patients. This finding highlights the importance of endothelial damage in ARDS.
- Open Access
- 9 November 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (6) , 1-2
Cardiac output measurements using the bioreactance technique in critically ill patients
Measurement of cardiac output (CO) using minimally invasive devices has gained popularity. In 11 patients we compared CO values obtained using the bioreactance technique - a new continuous, totally non-invasive CO monitor - with those obtained by semi-continuous thermodilution using a pulmonary artery catheter. We obtained CO measurements at study inclusion and after any relevant change in hemodynamic status (spontaneous or during fluid challenge, inotrope or vasopressor infusions). There was a poor correlation between the two techniques (r = 0.145). These data suggest that caution should be applied when using bioreactance devices in critically ill patients.
- 9 November 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (6) , 1-2
Open AccessCardiac output measurements using the bioreactance technique in critically ill patients
Measurement of cardiac output (CO) using minimally invasive devices has gained popularity. In 11 patients we compared CO values obtained using the bioreactance technique - a new continuous, totally non-invasive CO monitor - with those obtained by semi-continuous thermodilution using a pulmonary artery catheter. We obtained CO measurements at study inclusion and after any relevant change in hemodynamic status (spontaneous or during fluid challenge, inotrope or vasopressor infusions). There was a poor correlation between the two techniques (r = 0.145). These data suggest that caution should be applied when using bioreactance devices in critically ill patients.
- Open Access
- 29 June 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (3) , 134-2
Pocket ultrasound devices for focused echocardiography
- 29 June 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (3) , 134-2
Open AccessPocket ultrasound devices for focused echocardiography