Latest Publications

  • Open Access

    Exploring the Effect of Indoor Thermal Comfort using Iris Dampers: A Justification Study

    by Nur’aMirah Busu, Norasikin Mat Isa, Azian Hariri, Mohamed Hussein, David Shina Adebayo

    This study explores the impact of fixed damper openings on indoor thermal comfort in a lab-scaled chamber. Experiments with maximum, medium, and minimum iris damper openings were conducted under various occupancy conditions. Results show that the maximum opening maintained temperatures close to the ideal 24°C with minimal fluctuations. In contrast, medium and minimum openings resulted in higher temperature variability and less efficient air distribution. Statistical analysis highlighted significant differences in temperature stability among the different damper settings. The maximum opening ensured a stable temperature range, while the minimum opening caused noticeable temperature stratification and discomfort, especially with more occupants. The findings indicate that fixed damper openings are inadequate for maintaining consistent thermal comfort due to their lack of adaptability. This underscores the need for advanced control systems that can dynamically adjust damper positions to ensure optimal indoor temperature regulation and improve energy efficiency.


  • Open Access

    Evaluation of Sick Building Syndrome (SBS) Symptoms and Measurement of Indoor Air Quality (IAQ) Parameter in One of Hospital Building in Johor

    by Mohd Arif Rosli, Muhamad Shahril Mohd Abdullah, Azian Hariri, Amir Abdullah Muhamad Damanhuri, Berkah Fajar Tamtama, Nur Ain Ebas, Nor Mohd Razif Noraini

    This study assesses Sick Building Syndrome (SBS) symptoms and Indoor Air Quality (IAQ) parameters among hospital ward staff. Utilizing a thorough methodology, a questionnaire survey and IAQ monitoring were conducted, aligning with Department of Occupational Safety and Health (DOSH) guidelines. IAQ parameters are generally within limits, except for relative humidity which recorded values of 73.09-75.23% for Ward 16 and 62.33-71.13% for Ward 18. Respondents expressed concerns about room conditions, including temperature variations, unpleasant odours, and noise. Fatigue, difficulties concentrating, and various respiratory symptoms were prevalent, suggesting potential health issues linked to indoor pollutants. The findings underscore the urgency of addressing IAQ concerns to improve the well-being of patients and healthcare workers.


  • Open Access

    Comprehensive Review on the Relationship between Duct Cleanliness and Airborne Contaminants

    by Mohd Arif Rosli, Muhamad Shahril Mohd Abdullah, Azian Hariri, Amir Abdullah Muhamad Damanhuri, Berkah Fajar Tamtama, Nor Mohd Razif Noraini

    This study investigates the relationship between Indoor Air Quality (IAQ) and air duct cleanliness, addressing the rising concern for human well-being. Airborne contaminants like dust, mold, and bacteria are identified as significant threats to IAQ, with potential health consequences. The study will also explore the several established safety and health guidelines and duct characteristics that influenced IAQ. Consequently, the primary research goal is to examine the relationship between duct cleanliness and airborne contaminants in the building environment and determine whether air duct cleaning effectively reduces these contaminants. By thoroughly reviewing studies and established standards, we examine IAQ contaminants and explore the effects of duct cleaning, along with its potential health advantages. Findings emphasize duct cleaning's potential to enhance IAQ, reduce exposure to pollutants, and its importance for building owners, facility managers, and stakeholders in safeguarding occupants' health and comfort.


  • Open Access

    Prototype Development of Modified Roof Turbine Ventilator for Thermal Comfort Enhancement

    by Mithun Mondal, Kamarul-Azhar Kamarudin, Azian Hariri, Muhammad Ridhuan Hassan, Muhd Hafeez Zainulabidin

    A mechanical ventilator known as a turbine ventilator harnesses the wind to supply natural ventilation. Due to their high performance and cheap running costs, these devices are increasingly being used to ventilate areas. This study evaluated the impact of a modified turbine ventilator system on thermal comfort and airflow inside a room. The results showed that the natural ventilation system failed to meet the ASHRAE Standard 55-2020 for thermal comfort. The installation of a turbine ventilator decreases the temperature by 1.3°C but still did not meet the standards. The modified turbine ventilator system consisted of a 305 mm diameter inner 12V, 12W exhaust fan installed in a 500 mm diameter ventilator and connected to a 50W, 12V Monocrystalline Solar Panel showed the greatest improvement with a decrease in room temperature of 4.4°C, an increase in airflow, and full compliance with the ASHRAE Standard 55-2020. The study concludes that modifications to the natural ventilation system can significantly improve thermal comfort and airflow, with the modified ventilator system being the most effective solution.


  • Open Access

    Energy Profiling and Potential Energy Saving of a Keropok Lekor Small Industry

    by Ahmad Wafri Ahmad Wardi, Azian Hariri, Normayati Nordin, Norasikin Mat Isa, Nurul Fitriah Nasir, Hanis Zakaria, Nor Adrian Nor Salim, Winardi Sani, Haris Puspito Buwono

    Malaysia Statistical Business Register (MSBR) released by the Department of Statistics Malaysia (DOSM) highlighted that the total number of SMEs in Malaysia was 97.2% of the total business establishment in 2020. Keropok lekor is a favourite snack in Malaysia and this small industry blossomed in the area near the ocean fishing industry. This study aimed to conduct an energy profiling study to identify the energy consumption profile, electricity usage analysis, and propose cost-benefit energy conservation measures (ECMs) for a selected keropok lekor small industry in Terengganu, Malaysia. The energy audit starts with a preliminary energy usage analysis by reviewing three years of electricity bills from 2019 to 2021. Then, the field data collection was conducted by measuring the illuminance level, air velocity, and air temperature at the shop area and two manufacturing (manufacturing 1 and 2) spaces. Results of the analysis showed that the freezers and chillers consumed the highest 71.3% of overall electrical usage. Applicable Energy Counter Measures (ECMs) were proposed to the small industry management from no cost to high-cost investment such as energy-saving training programs for the workers, organized and efficient usage of the freezers and chillers, replacing electrical appliances with efficient-energy appliances, retrofitting LED lamps, and installation of solar panels. The cost analysis showed 0.73 years of the pay-back period for LED tubes retrofitting and 6 years for solar panel installation. Overall, the energy profiling study was successfully conducted and applicable ECMs with cost-benefit analysis were also had been proposed to the small industry for effective energy management.

  • Open Access

    Review of: "Thermal Comfort Temperature Evaluation in Hospital Wards for Patient Safety and Climate Change Sustainability"

    by Azian Hariri

    1)The abstract can be enhanced by outlining the methodology accurately and listing the parameters investigated. 2)There is some sentences that cannot be understand such as "warming climate Reference Minimum 26.6 C Reference Average Ai...

  • Open Access

    Influence of Air Velocity on Thermal Comfort and Performance of Students in Naturally Ventilated Classrooms in Tropical Climate

    by Mohamad Nor Azhari Nor Azli, Azian Hariri, Zi Yao Chong, Muhammad Aidil Khasri, Amir Abdullah Muhamad Damanhuri, Mohd Syafiq Syazwan Mustafa, Hashim Kabrein

    Air velocity is among the most important factors influencing thermal comfort in naturally ventilated spaces in hot and humid tropical climates. It is important to have air velocity that suits comfort needs and enhances the student's learning performance in the classroom, especially in schools that rely only on natural ventilation assisted by ceiling fans. In this study, the thermal comfort and learning performance of students in a selected naturally ventilated classroom at a secondary school in Segamat, Johor, Malaysia, were experimentally evaluated under different air velocity conditions during the peak temperature period during the school session. Throughout the experiment, physical measurement and a subjective evaluation questionnaire were conducted for thermal comfort analysis and to gather the student’s thermal environment evaluation in the classroom. Students’ learning performance was assessed through simple reaction and digit span tests based on the WHO Neurobehavioral Core Test Battery (NCTB). All the assessment results were statistically analyzed, and the relationships among indoor air velocity, thermal comfort, and learning performance were obtained. The result showed optimal learning performance was significant when students felt “slightly cool” and air velocity was more than 0.95 m/s. Hotter environments and a lack of air movement were found to be causes of declining student performance. In conclusion, it is suggested that the comfort zone in a naturally ventilated classroom for school students should be set within the range of -1 (slightly cool) with an air velocity greater than 0.76 m/s.


  • Open Access

    The Comparison of P, PI and PID Strategy Performance as Temperature Controller in Active Iris Damper for Centralized Air Conditioning System

    by Nur’aMirah Busu, Norasikin Mat Isa, Azian Hariri, Mohamed Hussein

    The topic of maintaining thermal comfort efficiency in the heating, ventilation and air conditioning (HVAC) sector has always been tricky due to numerous challenges. The study focused on the challenge of under-actuated zones in non – residential and commercial buildings. The active iris damper with the integration of thermal controller is proposed to control the indoor temperature. Besides, integration of PID control strategy will be a tempting control system in enhancing the thermal performance of the building. Again, the PID controller has proven good compatibility as a primary closed-loop mechanism to maintain a comfortable room temperature. The development of the control system is done through the Arduino platform with LabVIEW as the front panel and data logging platform. The Heuristic tuning method was employed to obtain optimal gains for P, PI and PID controllers. The performance of each controller was tested by observing their ability to maintain steadily at the desired temperature set point. These tests conveyed that the best controller for this application is the PID controller. It reached the desired temperature set point and maintained it even with a temperature disruption. This study indicates that an active iris damper can effectively maintain the thermal comfort performance of indoor environment with the implementation of PID strategy, thus remedying some of the problems faced by centralized air-conditioning systems.


  • Open Access

    Comparison of Thermal Comfort Condition of Naturally Ventilated Courtyard, Semi-Outdoor and Indoor Air-Conditioned Spaces in Tropical Climate

    by Mohammad Zaraa Allah, Azian Hariri, Haslinda Mohamed Kamar

    Universiti Tun Hussein Onn Malaysia (UTHM) elibrary is in the hot and humid tropical climate of Malaysia and has a distinctive feature of a circular courtyard and semi-outdoor spaces for practical public spaces and energy saving. This study was conducted on the ground level of the library which consists of an open terrace consisting of a cafeteria, a garden in the circular courtyard, and an air-conditioned seminar room. This study aimed to compare the thermal comfort condition of these spaces through physical and subjective measurements. Physical measurement was conducted for air temperature, relative humidity, air velocity and mean radiant temperature at the two selected sampling points on each investigated area positioned at 0.6 meters from the floor. Data were collected for three days in each area during two periods of time; 9 to 11 am and 2 to 4 pm. Subjective measurements were also collected through the distributed questionnaire to 150 respondents to determine the thermal sensation votes (TSV) of each investigated area. Calculations based on physical measurement showed the thermal comfort for both the cafeteria and garden were within 90% thermal comfort acceptability limit. PMV value for the air-conditioned seminar room was -0.45 with a PPD value of 9.03%. Both results complied with the ASHRAE 55 Standards for the acceptable condition for both naturally and air-conditioned spaces. The regression analysis showed that the comfort air temperature range based on the human response method for semi-outdoor spaces and indoor spaces were 24.8 0C to 29.0 0C and 20 0C to 23.5 0C respectively. The PMV regression analysis showed that the comfort air temperature range for indoor space was 22.4 0C to 23.5 0C. Results of the study showed that respondents perceived a higher comfort temperature range in the courtyard and cafeteria compared to indoor air-conditioned spaces, but still within the recommended range of ASHRAE 55 standard. The results of the study concluded that semi-outdoor places can potentially be designed as practical public spaces for comfortable and sustainable spaces.


  • Open Access

    Preliminary Study on Student’s Performance and Thermal Comfort in Classroom

    by Chong Zi Yao, Mohamad Nor Azhari Nor Azli, Azian Hariri, Amir Abdullah Muhamad Damanhuri, Mohd Syafiq Syazwan Mustafa

    In Malaysia, students spend up to 33% of their day in classrooms and school buildings. Previous research had shown that thermal comfort conditions in educational buildings can stimulate student productivity. This study aimed to preliminary investigate the relationship between thermal sensation and student performance in the classroom. Data collection was conducted in a selected classroom at a secondary school in Segamat, Johor. All data were collected for three days. Physical measurement data were taken using thermal comfort equipment, KIMO AMI 310 for indoor measurement (air temperature, mean radiant temperature, air velocity, relative humidity), and TSI VelociCalc for outdoor measurement (air temperature, relative humidity). The thermal comfort satisfaction questionnaire was distributed to 36 students in the classroom. The learning performance was assessed through a simple reaction test and digit span test based on the WHO Neurobehavioral Core Test Battery (NCTB) method. The results of the thermal comfort satisfaction questionnaire clearly showed that the lower the fan speed, the more students preferred the cooler option. Furthermore, students performed better when the fan speed was increased. Based on the correlation analysis, it can be concluded that the learning performance and thermal preference vote (TPV) are positively correlated. As a result, students tend to get higher scores when they feel cooler. This study provides important preliminary information on classroom conditions in secondary schools in Malaysia and provides a better understanding of the relationship between thermal perception and student learning performance in the classroom.