    Exploring the Effect of Indoor Thermal Comfort using Iris Dampers: A Justification Study

    by Nur’aMirah Busu, Norasikin Mat Isa, Azian Hariri, Mohamed Hussein, David Shina Adebayo

    This study explores the impact of fixed damper openings on indoor thermal comfort in a lab-scaled chamber. Experiments with maximum, medium, and minimum iris damper openings were conducted under various occupancy conditions. Results show that the maximum opening maintained temperatures close to the ideal 24°C with minimal fluctuations. In contrast, medium and minimum openings resulted in higher temperature variability and less efficient air distribution. Statistical analysis highlighted significant differences in temperature stability among the different damper settings. The maximum opening ensured a stable temperature range, while the minimum opening caused noticeable temperature stratification and discomfort, especially with more occupants. The findings indicate that fixed damper openings are inadequate for maintaining consistent thermal comfort due to their lack of adaptability. This underscores the need for advanced control systems that can dynamically adjust damper positions to ensure optimal indoor temperature regulation and improve energy efficiency.


  • Open Access

    The Comparison of P, PI and PID Strategy Performance as Temperature Controller in Active Iris Damper for Centralized Air Conditioning System

    by Nur’aMirah Busu, Norasikin Mat Isa, Azian Hariri, Mohamed Hussein

    The topic of maintaining thermal comfort efficiency in the heating, ventilation and air conditioning (HVAC) sector has always been tricky due to numerous challenges. The study focused on the challenge of under-actuated zones in non – residential and commercial buildings. The active iris damper with the integration of thermal controller is proposed to control the indoor temperature. Besides, integration of PID control strategy will be a tempting control system in enhancing the thermal performance of the building. Again, the PID controller has proven good compatibility as a primary closed-loop mechanism to maintain a comfortable room temperature. The development of the control system is done through the Arduino platform with LabVIEW as the front panel and data logging platform. The Heuristic tuning method was employed to obtain optimal gains for P, PI and PID controllers. The performance of each controller was tested by observing their ability to maintain steadily at the desired temperature set point. These tests conveyed that the best controller for this application is the PID controller. It reached the desired temperature set point and maintained it even with a temperature disruption. This study indicates that an active iris damper can effectively maintain the thermal comfort performance of indoor environment with the implementation of PID strategy, thus remedying some of the problems faced by centralized air-conditioning systems.


  • Open Access

    An Experimental Study of Real-time Temperature Distribution using Iris Damper without Control System: A Justification Analysis

    by Nur’aMirah Busu, Norasikin Mat Isa, Azian Hariri, Mohamed Hussein

    Thermal comfort, influenced by temperature distribution, plays a crucial role in maintaining occupants' well-being and productivity within indoor environments. Most of the building with centralized air conditioning system is accommodated with inlet diffuser with fixed opening area of inlet air damper. This paper present the justification that the indoor temperature distribution is struggling to be maintained at ideal temperature when using fixed inlet air damper. Experimental study has been conducted using iris damper pattern with three opening type and 4 occupancy conditions. Results shows that when there is no occupant, the indoor temperature will keeps decreasing below 24°C. Meanwhile, with the increment of occupancy, the indoor temperature keeps increasing and able to reach up to 27°C. This condition will leads to thermal discomfort among occupants. Thus, a step-based control method is reliable to be implemented in manipulating the opening area of iris damper to maintain the indoor temperature at the ideal temperature.