Yannick Boursier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yannick Boursier has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Christian Morel
Aix-Marseille Universite
3 shared publications - Mathieu Dupont
CPPM, Aix-Marseille Université, CNRS/IN2P3, France
3 shared publications - A. André
Univ. Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3
2 shared publications - A. Garnier
CNRS/IN2P3, CPPM, Aix-Marseille University
2 shared publications C. Hoarau
Univ. Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3
2 shared publicationsD. Maneval
Centre Antoine Lacassagne
2 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (8) , 1309-1320
TIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy
We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF2 crystal (2 × 1.5 × 1.5 cm3) coupled to a 2 × 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF2 allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2σ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of ~ 107 protons.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (8) , 1309-1320
Open AccessTIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy
We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF2 crystal (2 × 1.5 × 1.5 cm3) coupled to a 2 × 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF2 allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2σ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of ~ 107 protons.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 382-387
A Fast Plastic Scintillator for Low-Intensity Proton Beam Monitoring
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the incident ion with a time resolution below 235 ps FWHM (100 ps rms) is required to provide a start signal for the acquisition. We have therefore developed a dedicated detector based on a fast organic scintillator (EJ-204) of 25 ×25 ×1 mm3 coupled to four SiPM strips that allow measuring the particle incident position by scintillation light sharing. The prototype was characterised with single protons of energies between 63 and 225 MeV at the MEDICYC and ProteusONE facilities of the Antoine Lacassagne proton therapy centre in Nice. We obtained a time resolution of 120 ps FWHM at 63 MeV, and a spatial resolution of 2 mm rms for single particles. Two identical detectors also allowed to measure the MEDICYC proton energy with 0.3% accuracy.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 382-387
A Fast Plastic Scintillator for Low-Intensity Proton Beam Monitoring
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the incident ion with a time resolution below 235 ps FWHM (100 ps rms) is required to provide a start signal for the acquisition. We have therefore developed a dedicated detector based on a fast organic scintillator (EJ-204) of 25 ×25 ×1 mm3 coupled to four SiPM strips that allow measuring the particle incident position by scintillation light sharing. The prototype was characterised with single protons of energies between 63 and 225 MeV at the MEDICYC and ProteusONE facilities of the Antoine Lacassagne proton therapy centre in Nice. We obtained a time resolution of 120 ps FWHM at 63 MeV, and a spatial resolution of 2 mm rms for single particles. Two identical detectors also allowed to measure the MEDICYC proton energy with 0.3% accuracy.
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 548-558
ProMeSCT: A Proximal Metric Algorithm for Spectral CT
The acquisition of a set of spectral Photon-Counting Computed Tomography (spectral PC-CT) measurements aims at uncovering both the spatial and energetic characteristics of the imaged body, which widens the potential of tomography compared to classical Computed Tomography (CT). In the preclinical context, the use of polychromatic beams induces spectral mixing and, as a consequence, the reconstruction procedure requires specific algorithmic tools more complex than the standard ones used in CT. In this paper, we propose a one-step inversion method to simultaneously separate and reconstruct the physical materials of an object observed in the context of spectral PC-CT. To do so, we carefully consider the underlying polychromatic model of the X-ray beam and combine it with a priori on the materials of the object to reconstruct. The simultaneous separation and reconstruction of materials is done by minimizing the resulting non-convex ill-posed inverse problem. The dimensionality of the data and object materials worsens the computational complexity of the problem.We propose an efficient optimization algorithm based on a proximal forward-backward algorithm that is accelerated by a metric, which is specifically designed for spectral PC-CT. The efficiency of our method called ProMeSCT is demonstrated on results obtained on 3D synthetic data with a simple regularization that encompasses the positivity of the quantities of interest.
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 548-558
ProMeSCT: A Proximal Metric Algorithm for Spectral CT
The acquisition of a set of spectral Photon-Counting Computed Tomography (spectral PC-CT) measurements aims at uncovering both the spatial and energetic characteristics of the imaged body, which widens the potential of tomography compared to classical Computed Tomography (CT). In the preclinical context, the use of polychromatic beams induces spectral mixing and, as a consequence, the reconstruction procedure requires specific algorithmic tools more complex than the standard ones used in CT. In this paper, we propose a one-step inversion method to simultaneously separate and reconstruct the physical materials of an object observed in the context of spectral PC-CT. To do so, we carefully consider the underlying polychromatic model of the X-ray beam and combine it with a priori on the materials of the object to reconstruct. The simultaneous separation and reconstruction of materials is done by minimizing the resulting non-convex ill-posed inverse problem. The dimensionality of the data and object materials worsens the computational complexity of the problem.We propose an efficient optimization algorithm based on a proximal forward-backward algorithm that is accelerated by a metric, which is specifically designed for spectral PC-CT. The efficiency of our method called ProMeSCT is demonstrated on results obtained on 3D synthetic data with a simple regularization that encompasses the positivity of the quantities of interest.
- 7 May 2013
- Published by Springer Nature in Solar Physics
- Vol. 288 (1) , 269-289
ARTEMIS II: A Second-Generation Catalog of LASCO Coronal Mass Ejections Including Mass and Kinetic Energy
- 7 May 2013
- Published by Springer Nature in Solar Physics
- Vol. 288 (1) , 269-289
ARTEMIS II: A Second-Generation Catalog of LASCO Coronal Mass Ejections Including Mass and Kinetic Energy
- Open Access
- 1 January 2012
- Published by American Institute of Mathematical Sciences (AIMS) in Inverse Problems and Imaging
- Vol. 6 (4) , 565-598
Some proximal methods for Poisson intensity CBCT and PET
Cone-Beam Computerized Tomography (CBCT) and Positron Emission Tomography (PET) are two complementary medical imaging modalities providing respectively anatomic and metabolic information on a patient. In the context of public health, one must address the problem of dose reduction of the potentially harmful quantities related to each exam protocol : X-rays for CBCT and radiotracer for PET. Two demonstrators based on a technological breakthrough (acquisition devices work in photon-counting mode) have been developed. It turns out that in this low-dose context, i.e. for low intensity signals acquired by photon counting devices, noise should not be approximated anymore by a Gaussian distribution, but is following a Poisson distribution. We investigate in this paper the two related tomographic reconstruction problems. We formulate separately the CBCT and the PET problems in two general frameworks that encompass the physics of the acquisition devices and the specific discretization of the object to reconstruct. We propose various fast numerical schemes based on proximal methods to compute the solution of each problem. In particular, we show that primal-dual approaches are well suited in the PET case when considering non differentiable regularizations such as Total Variation. Experiments on numerical simulations and real data are in favor of the proposed algorithms when compared with well-established methods.
- 1 January 2012
- Published by American Institute of Mathematical Sciences (AIMS) in Inverse Problems and Imaging
- Vol. 6 (4) , 565-598
Open AccessSome proximal methods for Poisson intensity CBCT and PET
Cone-Beam Computerized Tomography (CBCT) and Positron Emission Tomography (PET) are two complementary medical imaging modalities providing respectively anatomic and metabolic information on a patient. In the context of public health, one must address the problem of dose reduction of the potentially harmful quantities related to each exam protocol : X-rays for CBCT and radiotracer for PET. Two demonstrators based on a technological breakthrough (acquisition devices work in photon-counting mode) have been developed. It turns out that in this low-dose context, i.e. for low intensity signals acquired by photon counting devices, noise should not be approximated anymore by a Gaussian distribution, but is following a Poisson distribution. We investigate in this paper the two related tomographic reconstruction problems. We formulate separately the CBCT and the PET problems in two general frameworks that encompass the physics of the acquisition devices and the specific discretization of the object to reconstruct. We propose various fast numerical schemes based on proximal methods to compute the solution of each problem. In particular, we show that primal-dual approaches are well suited in the PET case when considering non differentiable regularizations such as Total Variation. Experiments on numerical simulations and real data are in favor of the proposed algorithms when compared with well-established methods.