Mathieu Dupont
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mathieu Dupont has a total of 135 co-authors. Here are the top co-authors by number of shared publications:
C. Morel
5 shared publications- Christian Morel
Aix-Marseille Universite
5 shared publications Christian Morel
4 shared publicationsY. Boursier
Aix-Marseille Université, CNRS/IN2P3, CPPM UMR 7346, 13288, Marseille, France
4 shared publicationsA. Bonissent
Aix-Marseille Université, CNRS/IN2P3, CPPM UMR 7346, 13288, Marseille, France
3 shared publicationsAlain Bonissent
Aix-Marseille Université, CNRS/IN2P3, CPPM UMR 7346, France
3 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (8) , 1309-1320
TIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy
We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF2 crystal (2 × 1.5 × 1.5 cm3) coupled to a 2 × 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF2 allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2σ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of ~ 107 protons.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (8) , 1309-1320
Open AccessTIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy
We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF2 crystal (2 × 1.5 × 1.5 cm3) coupled to a 2 × 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF2 allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2σ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of ~ 107 protons.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 382-387
A Fast Plastic Scintillator for Low-Intensity Proton Beam Monitoring
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the incident ion with a time resolution below 235 ps FWHM (100 ps rms) is required to provide a start signal for the acquisition. We have therefore developed a dedicated detector based on a fast organic scintillator (EJ-204) of 25 ×25 ×1 mm3 coupled to four SiPM strips that allow measuring the particle incident position by scintillation light sharing. The prototype was characterised with single protons of energies between 63 and 225 MeV at the MEDICYC and ProteusONE facilities of the Antoine Lacassagne proton therapy centre in Nice. We obtained a time resolution of 120 ps FWHM at 63 MeV, and a spatial resolution of 2 mm rms for single particles. Two identical detectors also allowed to measure the MEDICYC proton energy with 0.3% accuracy.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 382-387
A Fast Plastic Scintillator for Low-Intensity Proton Beam Monitoring
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the incident ion with a time resolution below 235 ps FWHM (100 ps rms) is required to provide a start signal for the acquisition. We have therefore developed a dedicated detector based on a fast organic scintillator (EJ-204) of 25 ×25 ×1 mm3 coupled to four SiPM strips that allow measuring the particle incident position by scintillation light sharing. The prototype was characterised with single protons of energies between 63 and 225 MeV at the MEDICYC and ProteusONE facilities of the Antoine Lacassagne proton therapy centre in Nice. We obtained a time resolution of 120 ps FWHM at 63 MeV, and a spatial resolution of 2 mm rms for single particles. Two identical detectors also allowed to measure the MEDICYC proton energy with 0.3% accuracy.
- 22 May 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1064
Characterization of IMIC, an implantable needle-shaped positron sensitive monolithic active pixel sensor for preclinical molecular neuroimaging
- 22 May 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1064
Characterization of IMIC, an implantable needle-shaped positron sensitive monolithic active pixel sensor for preclinical molecular neuroimaging
- Top Cited PapersOpen Access
- 14 May 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (10) , 10TR03
Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize, understand and create innovative emission tomography systems. In this paper, we reviewed the recent developments that have been proposed to simulate modern detectors and provide a comprehensive report on imaging systems that have been simulated and evaluated in GATE. Additionally, some methodological developments that are not specific for imaging but that can improve detector modeling and provide computation time gains, such as Variance Reduction Techniques and Artificial Intelligence integration, are described and discussed.
- 14 May 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (10) , 10TR03
Top Cited PapersOpen AccessAdvanced Monte Carlo simulations of emission tomography imaging systems with GATE
Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize, understand and create innovative emission tomography systems. In this paper, we reviewed the recent developments that have been proposed to simulate modern detectors and provide a comprehensive report on imaging systems that have been simulated and evaluated in GATE. Additionally, some methodological developments that are not specific for imaging but that can improve detector modeling and provide computation time gains, such as Variance Reduction Techniques and Artificial Intelligence integration, are described and discussed.
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 548-558
ProMeSCT: A Proximal Metric Algorithm for Spectral CT
The acquisition of a set of spectral Photon-Counting Computed Tomography (spectral PC-CT) measurements aims at uncovering both the spatial and energetic characteristics of the imaged body, which widens the potential of tomography compared to classical Computed Tomography (CT). In the preclinical context, the use of polychromatic beams induces spectral mixing and, as a consequence, the reconstruction procedure requires specific algorithmic tools more complex than the standard ones used in CT. In this paper, we propose a one-step inversion method to simultaneously separate and reconstruct the physical materials of an object observed in the context of spectral PC-CT. To do so, we carefully consider the underlying polychromatic model of the X-ray beam and combine it with a priori on the materials of the object to reconstruct. The simultaneous separation and reconstruction of materials is done by minimizing the resulting non-convex ill-posed inverse problem. The dimensionality of the data and object materials worsens the computational complexity of the problem.We propose an efficient optimization algorithm based on a proximal forward-backward algorithm that is accelerated by a metric, which is specifically designed for spectral PC-CT. The efficiency of our method called ProMeSCT is demonstrated on results obtained on 3D synthetic data with a simple regularization that encompasses the positivity of the quantities of interest.
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 548-558
ProMeSCT: A Proximal Metric Algorithm for Spectral CT
The acquisition of a set of spectral Photon-Counting Computed Tomography (spectral PC-CT) measurements aims at uncovering both the spatial and energetic characteristics of the imaged body, which widens the potential of tomography compared to classical Computed Tomography (CT). In the preclinical context, the use of polychromatic beams induces spectral mixing and, as a consequence, the reconstruction procedure requires specific algorithmic tools more complex than the standard ones used in CT. In this paper, we propose a one-step inversion method to simultaneously separate and reconstruct the physical materials of an object observed in the context of spectral PC-CT. To do so, we carefully consider the underlying polychromatic model of the X-ray beam and combine it with a priori on the materials of the object to reconstruct. The simultaneous separation and reconstruction of materials is done by minimizing the resulting non-convex ill-posed inverse problem. The dimensionality of the data and object materials worsens the computational complexity of the problem.We propose an efficient optimization algorithm based on a proximal forward-backward algorithm that is accelerated by a metric, which is specifically designed for spectral PC-CT. The efficiency of our method called ProMeSCT is demonstrated on results obtained on 3D synthetic data with a simple regularization that encompasses the positivity of the quantities of interest.
- 6 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
The ClearPET/XPAD prototype: Development of a simultaneous PET/CT scanner for mice
We developed the ClearPET/XPAD prototype: the first simultaneous PET/CT mouse scanner combining on the same rotating gantry ClearPET modules and the hybrid pixel camera XPAD3 facing an X-ray source. To demonstrate the capabilities of the new machine, we present the first simultaneous PET/CT scans of 68Ge and 22Na point sources, of a micro Derenzo phantom and of a live mouse injected in the tail vein with [18F]FDG.
- 6 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
The ClearPET/XPAD prototype: Development of a simultaneous PET/CT scanner for mice
We developed the ClearPET/XPAD prototype: the first simultaneous PET/CT mouse scanner combining on the same rotating gantry ClearPET modules and the hybrid pixel camera XPAD3 facing an X-ray source. To demonstrate the capabilities of the new machine, we present the first simultaneous PET/CT scans of 68Ge and 22Na point sources, of a micro Derenzo phantom and of a live mouse injected in the tail vein with [18F]FDG.
- 1 November 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (11) , C11010
A large surface X-ray camera based on XPAD3/CdTe single chip hybrids
The XPAD3 chip bump-bonded to a Si sensor has been widely used in preclinical micro-computed tomography and in synchrotron experiments. Although the XPAD3 chip is linear up to 60 keV, the performance of the XPAD3/Si hybrid detector is limited to energies below 30 keV, for which detection efficiencies remain above 20%. To overcome this limitation on detection efficiency in order to access imaging at higher energies, we decided to develop a camera based on XPAD3 single chips bump-bonded to high-Z CdTe sensors. We will first present the construction of this new camera, from the first tests of the single chip hybrids to the actual mechanical assembly. Then, we will show first images and stability tests performed on the D2AM beam line at ESRF synchrotron facility with the fully assembled camera.
- 1 November 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (11) , C11010
A large surface X-ray camera based on XPAD3/CdTe single chip hybrids
The XPAD3 chip bump-bonded to a Si sensor has been widely used in preclinical micro-computed tomography and in synchrotron experiments. Although the XPAD3 chip is linear up to 60 keV, the performance of the XPAD3/Si hybrid detector is limited to energies below 30 keV, for which detection efficiencies remain above 20%. To overcome this limitation on detection efficiency in order to access imaging at higher energies, we decided to develop a camera based on XPAD3 single chips bump-bonded to high-Z CdTe sensors. We will first present the construction of this new camera, from the first tests of the single chip hybrids to the actual mechanical assembly. Then, we will show first images and stability tests performed on the D2AM beam line at ESRF synchrotron facility with the fully assembled camera.
- 2 July 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (14) , 5497-5511
K-edge imaging with the XPAD3 hybrid pixel detector, direct comparison of CdTe and Si sensors
We investigate the improvement from the use of high-Z CdTe sensors for pre-clinical K-edge imaging with the hybrid pixel detectors XPAD3. We compare XPAD3 chips bump bonded to Si or CdTe sensors in identical experimental conditions. Image performance for narrow energy bin acquisitions and contrast-to-noise ratios of K-edge images are presented and compared. CdTe sensors achieve signal-to-noise ratios at least three times higher than Si sensors within narrow energy bins, thanks to their much higher detection efficiency. Nevertheless Si sensors provide better contrast-to-noise ratios in K-edge imaging when working at equivalent counting statistics, due to their better estimation of the attenuation coefficient of the contrast agent. Results are compared to simulated data in the case of the XPAD3/Si detector. Good agreement is observed when including charge sharing between pixels, which have a strong impact on contrast-to-noise ratios in K-edge images.
- 2 July 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (14) , 5497-5511
K-edge imaging with the XPAD3 hybrid pixel detector, direct comparison of CdTe and Si sensors
We investigate the improvement from the use of high-Z CdTe sensors for pre-clinical K-edge imaging with the hybrid pixel detectors XPAD3. We compare XPAD3 chips bump bonded to Si or CdTe sensors in identical experimental conditions. Image performance for narrow energy bin acquisitions and contrast-to-noise ratios of K-edge images are presented and compared. CdTe sensors achieve signal-to-noise ratios at least three times higher than Si sensors within narrow energy bins, thanks to their much higher detection efficiency. Nevertheless Si sensors provide better contrast-to-noise ratios in K-edge imaging when working at equivalent counting statistics, due to their better estimation of the attenuation coefficient of the contrast agent. Results are compared to simulated data in the case of the XPAD3/Si detector. Good agreement is observed when including charge sharing between pixels, which have a strong impact on contrast-to-noise ratios in K-edge images.