Radosław Łukasz Gwarda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Radosław Łukasz Gwarda has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Tadeusz H. Dzido
Medical University of Lublin
5 shared publications- Tadeusz Henryk Dzido
Department of Physical Chemistry, Pharmaceutical Faculty, Medical University of Lublin, 4A Chodźki Street, Lublin, 20-093, Poland
5 shared publications Tadeusz Henryk Dzido
Department of Physical Chemistry, Chair of Chemistry, Faculty of Pharmacy, Medical University of Lublin, 4a Chodźki Str., 20-093 Lublin, Poland
4 shared publications- Aneta Hałka-Grysińska
Department of Physical Chemistry, Medical University of Lublin, Lublin, Poland
2 shared publications - Dariusz Matosiuk
Department of Synthesis and Chemical Technology of Pharmaceutical Substances, Faculty of Pharmacy, Medical University of Lublin, 20-059 Lublin, Poland
2 shared publications Monika Aletańska-Kozak
Chair and Department of Synthesis and Chemical Technology of Pharmaceutical Substances, Faculty of Pharmacy with Medical Analytics Division, Medical University of Lublin, 4a Chodźki St., 20-093 Lublin, Poland
2 shared publications
Latest Publications
- Open Access
- 28 May 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (11) , 9389
Reverse-Polarization High-Performance Layer Electrochromatography—A New Approach to Anion Separation
High-performance layer electrochromatography (HPLEC) combines the advantages of overpressured-layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC) while overcoming some of their limitations. HPLEC equipment can work in various HPLEC, OPLC, and PPEC modes. The equipment enables HPLEC analysis also with an electroosmotic effect directed against the hydrodynamic flow of the mobile phase. The change in the electric field direction in the separation system does not result in a change in either the direction of the mobile phase flow or the direction of solute migration. The hydrodynamic flow generated by the pump dominates the electroosmotic effect and enables separation against the direction of the latter. Reversed-polarization HPLEC may be advantageous for the analysis of anionic compounds, as it facilitates faster and more selective separation than OPLC performed in similar conditions. This separation mode provides a new possibility to develop and optimize separation methods by performing separation against the electroosmotic effect and without need of any modification of the adsorbent surface. A drawback of this separation mode is the increase in the backpressure at the mobile phase inlet and the limitation of the mobile phase flow rate. Currently, contrary to the single-channel mode, multi-channel reverse-polarity HPLEC still requires some technical and methodological improvements.
- 28 May 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (11) , 9389
Open AccessReverse-Polarization High-Performance Layer Electrochromatography—A New Approach to Anion Separation
High-performance layer electrochromatography (HPLEC) combines the advantages of overpressured-layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC) while overcoming some of their limitations. HPLEC equipment can work in various HPLEC, OPLC, and PPEC modes. The equipment enables HPLEC analysis also with an electroosmotic effect directed against the hydrodynamic flow of the mobile phase. The change in the electric field direction in the separation system does not result in a change in either the direction of the mobile phase flow or the direction of solute migration. The hydrodynamic flow generated by the pump dominates the electroosmotic effect and enables separation against the direction of the latter. Reversed-polarization HPLEC may be advantageous for the analysis of anionic compounds, as it facilitates faster and more selective separation than OPLC performed in similar conditions. This separation mode provides a new possibility to develop and optimize separation methods by performing separation against the electroosmotic effect and without need of any modification of the adsorbent surface. A drawback of this separation mode is the increase in the backpressure at the mobile phase inlet and the limitation of the mobile phase flow rate. Currently, contrary to the single-channel mode, multi-channel reverse-polarity HPLEC still requires some technical and methodological improvements.
- Open Access
- 18 February 2023
- Published by Medical University of Lublin in Current Issues in Pharmacy and Medical Sciences
- Vol. {"content-
Authors’ Errata to The Paper on
Sciendo provides publishing services and solutions to academic and professional organizations and individual authors. We publish journals, books, conference proceedings and a variety of other publications.
- 18 February 2023
- Published by Medical University of Lublin in Current Issues in Pharmacy and Medical Sciences
- Vol. {"content-
Open AccessAuthors’ Errata to The Paper on
Sciendo provides publishing services and solutions to academic and professional organizations and individual authors. We publish journals, books, conference proceedings and a variety of other publications.
- Open Access
Comparison of Overpressured-Layer Chromatography and High-Performance/High-Pressure Layer Electrochromatography Using the New Prototype Equipment in Various Operational Modes
In our previous paper we have presented the new prototype equipment and introduced a new analytical technique—high-performance/high-pressure layer electrochromatography (HPLEC), a combination of overpressured-layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC). In this paper, the work of the equipment in various operational modes is investigated. Some difficulties and challenges related to various aspects of separation are discussed. The OPLC and HPLEC techniques are compared in terms of selectivity and performance. The results show that our equipment can be successfully used for singe- and multichannel OPLC and HPLEC separations in various sample application and detection modes. It includes the high-throughput, multichannel, and fully automated online separation of multiple samples simultaneously. The equipment allows for the independent optimization of various operational parameters. HPLEC combines the advantages of column/capillary and planar separation techniques while overcoming their limitations. It also combines the advantages and overcomes the drawbacks of OPLC and PPEC. It provides hydrodynamic flow of the mobile phase, irrespective of the voltage used and/or the mobile phase composition. Thus, any optimization of the composition and the voltage can be used independently. Both can be used to obtain the required selectivity of separation. The voltage can be used to facilitate the mobile phase flow and accelerate the analysis.
Open AccessComparison of Overpressured-Layer Chromatography and High-Performance/High-Pressure Layer Electrochromatography Using the New Prototype Equipment in Various Operational Modes
In our previous paper we have presented the new prototype equipment and introduced a new analytical technique—high-performance/high-pressure layer electrochromatography (HPLEC), a combination of overpressured-layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC). In this paper, the work of the equipment in various operational modes is investigated. Some difficulties and challenges related to various aspects of separation are discussed. The OPLC and HPLEC techniques are compared in terms of selectivity and performance. The results show that our equipment can be successfully used for singe- and multichannel OPLC and HPLEC separations in various sample application and detection modes. It includes the high-throughput, multichannel, and fully automated online separation of multiple samples simultaneously. The equipment allows for the independent optimization of various operational parameters. HPLEC combines the advantages of column/capillary and planar separation techniques while overcoming their limitations. It also combines the advantages and overcomes the drawbacks of OPLC and PPEC. It provides hydrodynamic flow of the mobile phase, irrespective of the voltage used and/or the mobile phase composition. Thus, any optimization of the composition and the voltage can be used independently. Both can be used to obtain the required selectivity of separation. The voltage can be used to facilitate the mobile phase flow and accelerate the analysis.
- Open Access
- 14 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (25) , 9091-9096
High Performance (High Pressure) Layer Electrochromatography Separation Technique: Equipment and Preliminary Results
We present a new prototype device and propose a new analytical technique: high performance (high pressure) layer electrochromatography (HPLEC). The equipment provides a combination of overpressured layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC), yet it still enables researchers to perform each of these analyses separately. In comparison to PPEC, HPLEC provides hydrodynamic flow of the mobile phase, irrespective of the voltage used and the mobile phase composition. The advantages of HPLEC over OPLC include the possibility of the use of the electrophoretic effect to influence the selectivity of separation and the use of the electroosmotic effect to facilitate the mobile phase flow in order to decrease backpressure and increase the flow velocity. Many operational parameters can be freely adjusted and optimized independently. The equipment is fully automated and can work in various separation/operational modes, including combinations of online/offline sample application and detection. We present preliminary results of simultaneous, fully online, multichannel HPLEC separation of analgesic drugs (including acetaminophen, ibuprofen, and tramadol) as an example of increasing analysis throughput.
- 14 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (25) , 9091-9096
Open AccessHigh Performance (High Pressure) Layer Electrochromatography Separation Technique: Equipment and Preliminary Results
We present a new prototype device and propose a new analytical technique: high performance (high pressure) layer electrochromatography (HPLEC). The equipment provides a combination of overpressured layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC), yet it still enables researchers to perform each of these analyses separately. In comparison to PPEC, HPLEC provides hydrodynamic flow of the mobile phase, irrespective of the voltage used and the mobile phase composition. The advantages of HPLEC over OPLC include the possibility of the use of the electrophoretic effect to influence the selectivity of separation and the use of the electroosmotic effect to facilitate the mobile phase flow in order to decrease backpressure and increase the flow velocity. Many operational parameters can be freely adjusted and optimized independently. The equipment is fully automated and can work in various separation/operational modes, including combinations of online/offline sample application and detection. We present preliminary results of simultaneous, fully online, multichannel HPLEC separation of analgesic drugs (including acetaminophen, ibuprofen, and tramadol) as an example of increasing analysis throughput.
- Open Access
- 1 September 2018
- Published by Springer Nature in Chromatographia
- Vol. 81 (11) , 1589-1594
Correlation of Migration Distance of Peptides in High-Performance Thin-Layer Chromatography and Pressurized Planar Electrochromatography Systems
- 1 September 2018
- Published by Springer Nature in Chromatographia
- Vol. 81 (11) , 1589-1594
Open AccessCorrelation of Migration Distance of Peptides in High-Performance Thin-Layer Chromatography and Pressurized Planar Electrochromatography Systems
- 1 February 2018
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 31 (1) , 57-60
Comparison of the Separation Selectivity of Purine Derivatives in High-Performance Thin-Layer Chromatography and Pressurized Planar Electrochromatography Systems
Our article presents the comparison of two methods: high-performance thin-layer chromatography (HPTLC) and pressurized planar electrochromatography (PPEC), implemented for the separation of a test mixture of purine derivatives. The two methods were compared in terms of separation selectivity and separation time. Our results show that PPEC enables the separation of the mixture (azathioprine, caffeine, theobromine, theophylline and acyclovir) which could not be efficiently separated in the HPTLC system, due to the different selectivities of separation. PPEC also enables to obtain a much faster separation, performed on the longer distance, in comparison to HPTLC. This makes PPEC a technique which can be useful in the analysis of purine derivatives and other drugs.
- 1 February 2018
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 31 (1) , 57-60
Comparison of the Separation Selectivity of Purine Derivatives in High-Performance Thin-Layer Chromatography and Pressurized Planar Electrochromatography Systems
Our article presents the comparison of two methods: high-performance thin-layer chromatography (HPTLC) and pressurized planar electrochromatography (PPEC), implemented for the separation of a test mixture of purine derivatives. The two methods were compared in terms of separation selectivity and separation time. Our results show that PPEC enables the separation of the mixture (azathioprine, caffeine, theobromine, theophylline and acyclovir) which could not be efficiently separated in the HPTLC system, due to the different selectivities of separation. PPEC also enables to obtain a much faster separation, performed on the longer distance, in comparison to HPTLC. This makes PPEC a technique which can be useful in the analysis of purine derivatives and other drugs.
- 1 April 2017
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 30 (2) , 113-120
Reversed-phase stepwise gradient thin-layer chromatography of 19 test dye mixtures with a single void volume of the mobile phase
- 1 April 2017
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 30 (2) , 113-120
Reversed-phase stepwise gradient thin-layer chromatography of 19 test dye mixtures with a single void volume of the mobile phase
- 1 April 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1440, 229-239
Influence of carboxylic ion-pairing reagents on retention of peptides in thin-layer chromatography systems with C18 silica-based adsorbents
- 1 April 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1440, 229-239
Influence of carboxylic ion-pairing reagents on retention of peptides in thin-layer chromatography systems with C18 silica-based adsorbents