Aneta Hałka-Grysińska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aneta Hałka-Grysińska has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Tadeusz H. Dzido
Department of Physical Chemistry, Medical University of Lublin, Lublin, Poland
6 shared publicationsAndrzej Torbicz
Department of Physical Chemistry, Medical University of Lublin, Lublin, Poland
2 shared publicationsPaweł W. Płocharz
Department of Cosmetology, Faculty of Physical Education and Sport in Biala Podlaska, Jozef Pilsudski University of Physical Education in Warsaw, Biala Podlaska, Poland
2 shared publications- Radosław Łukasz Gwarda
Department of Physical Chemistry, Faculty of Pharmacy, Medical University of Lublin, 4a Chodźki Str., 20-093 Lublin, Poland
2 shared publications Tadeusz Henryk Dzido
Department of Physical Chemistry, Medical University of Lublin, Lublin, Poland
2 shared publications- Tadeusz Henryk Dzido
Department of Physical Chemistry, Pharmaceutical Faculty, Medical University of Lublin, 4A Chodźki Street, Lublin, 20-093, Poland
2 shared publications
Latest Publications
- Open Access
- 20 April 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (6) , 399-406
Application High-Performance Thin-Layer Chromatography with Controlled Eluent Velocity to Determine Fingerprints of Various Poplar Species Buds Extracts: Optimization of Operating Variables
- 20 April 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (6) , 399-406
Open AccessApplication High-Performance Thin-Layer Chromatography with Controlled Eluent Velocity to Determine Fingerprints of Various Poplar Species Buds Extracts: Optimization of Operating Variables
- 1 June 2022
- Published by Springer Nature in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 35 (3) , 243-250
Influence of starting zone on the efficiency of micro-thin-layer chromatography with controlled mobile phase flow rate
- 1 June 2022
- Published by Springer Nature in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 35 (3) , 243-250
Influence of starting zone on the efficiency of micro-thin-layer chromatography with controlled mobile phase flow rate
- 1 July 2021
- Published by Elsevier in Journal of Chromatography A
- Vol. 1649, 462224
Reversed-phase pH gradient thin-layer chromatography of biologically active substances with controlled developing solvent velocity
- 1 July 2021
- Published by Elsevier in Journal of Chromatography A
- Vol. 1649, 462224
Reversed-phase pH gradient thin-layer chromatography of biologically active substances with controlled developing solvent velocity
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1610, 460516
Reversed-phase stepwise gradient thin-layer chromatography of test dye mixtures with controlled developing solvent velocity
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1610, 460516
Reversed-phase stepwise gradient thin-layer chromatography of test dye mixtures with controlled developing solvent velocity
- 1 November 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1575, 91-99
Thin-layer chromatogram development with a moving pipette delivering the mobile phase onto the surface of the adsorbent layer
- 1 November 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1575, 91-99
Thin-layer chromatogram development with a moving pipette delivering the mobile phase onto the surface of the adsorbent layer
- 1 April 2017
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 30 (2) , 113-120
Reversed-phase stepwise gradient thin-layer chromatography of 19 test dye mixtures with a single void volume of the mobile phase
- 1 April 2017
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 30 (2) , 113-120
Reversed-phase stepwise gradient thin-layer chromatography of 19 test dye mixtures with a single void volume of the mobile phase
- 1 January 2015
- Published by Elsevier
- p. 135-165
Pressurized Planar Electrochromatography
- Open Access
- 1 June 2014
- Published by Springer Nature in Chromatographia
- Vol. 77 (13-14) , 941-950
Influence of the Modifier Type and its Concentration on Electroosmotic Flow of the Mobile Phase in Pressurized Planar Electrochromatography
The aim of this work was to find a relationship between electroosmotic flow (EOF) velocity of the mobile phase in pressurized planar electrochromatography (PPEC) and physicochemical properties like zeta potential, dielectric constant, and viscosity of the mobile phase as well as its composition. The study included different types of organic modifiers (acetonitrile, methanol, ethanol, acetone, formamide, N-methylformamide and N,N-dimethylformamide) in the full concentration range. In all experiments, chromatographic glass plates HPTLC RP-18 W from Merck (Darmstadt) were used as a stationary phase. During the study we found that there is no linear correlation between EOF velocity of the mobile phase and single variables such as zeta potential or dielectric constant or viscosity. However, there is quite strong linear correlation between EOF velocity of the mobile phase and variable obtained by multiplying zeta potential of the stationary phase–mobile phase interface, by dielectric constant of the mobile phase solution and dividing by viscosity of the mobile phase. Therefore, it could be concluded that the PPEC system fulfilled the Helmholtz–Smoluchowski equation.
- 1 June 2014
- Published by Springer Nature in Chromatographia
- Vol. 77 (13-14) , 941-950
Open AccessInfluence of the Modifier Type and its Concentration on Electroosmotic Flow of the Mobile Phase in Pressurized Planar Electrochromatography
The aim of this work was to find a relationship between electroosmotic flow (EOF) velocity of the mobile phase in pressurized planar electrochromatography (PPEC) and physicochemical properties like zeta potential, dielectric constant, and viscosity of the mobile phase as well as its composition. The study included different types of organic modifiers (acetonitrile, methanol, ethanol, acetone, formamide, N-methylformamide and N,N-dimethylformamide) in the full concentration range. In all experiments, chromatographic glass plates HPTLC RP-18 W from Merck (Darmstadt) were used as a stationary phase. During the study we found that there is no linear correlation between EOF velocity of the mobile phase and single variables such as zeta potential or dielectric constant or viscosity. However, there is quite strong linear correlation between EOF velocity of the mobile phase and variable obtained by multiplying zeta potential of the stationary phase–mobile phase interface, by dielectric constant of the mobile phase solution and dividing by viscosity of the mobile phase. Therefore, it could be concluded that the PPEC system fulfilled the Helmholtz–Smoluchowski equation.
- 16 July 2013
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 36 (17) , 2512-2523
OPTIMIZATION OF SOME VARIABLES OF ON-LINE INJECTION IN PRESSURIZED PLANAR ELECTROCHROMATOGRAPHY
Pressurized planar electrochromatography (PPEC) is a separating technique, in which an electric field is applied to force movement of the mobile phase through a porous media (electroosmotic effect). High separation efficiency, fast separation, and changes in separation selectivity in comparison to liquid chromatography, especially to thin-layer chromatography (planar chromatography, TLC) are features of this technique. Our group has recently introduced the prototype device, which enables simultaneous on-line injection of six samples on chromatographic plate in a stream of the mobile phase. In this paper influence of some operating variables of on-line injection mode on efficiency of PPEC separation system is shown and discussed.
- 16 July 2013
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 36 (17) , 2512-2523
OPTIMIZATION OF SOME VARIABLES OF ON-LINE INJECTION IN PRESSURIZED PLANAR ELECTROCHROMATOGRAPHY
Pressurized planar electrochromatography (PPEC) is a separating technique, in which an electric field is applied to force movement of the mobile phase through a porous media (electroosmotic effect). High separation efficiency, fast separation, and changes in separation selectivity in comparison to liquid chromatography, especially to thin-layer chromatography (planar chromatography, TLC) are features of this technique. Our group has recently introduced the prototype device, which enables simultaneous on-line injection of six samples on chromatographic plate in a stream of the mobile phase. In this paper influence of some operating variables of on-line injection mode on efficiency of PPEC separation system is shown and discussed.
- Open Access
- 5 March 2013
- Published by Springer Nature in Chromatographia
- Vol. 76 (19) , 1271-1279
A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application
- 5 March 2013
- Published by Springer Nature in Chromatographia
- Vol. 76 (19) , 1271-1279
Open AccessA Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application