SVSantaram Vallurupalli

Santaram Vallurupalli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Santaram Vallurupalli has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Screw Fixation Compared with Suture-Button Fixation of Isolated Lisfranc Ligament Injuries

    by Vinod K. Panchbhavi, Santaram Vallurupalli, Jinping Yang, Clark R. Andersen

    Background: A cannulated screw is currently used to reduce and stabilize diastasis at the Lisfranc joint. The screw requires removal and may break in situ. A suture button does not have these disadvantages, but it is not known if it can provide stability similar to that provided by a cannulated screw or an intact Lisfranc ligament. The objective of the present study was to compare the stability provided by a suture button with that provided by a screw when used to stabilize the diastasis associated with Lisfranc ligament injury. Methods: Fourteen fresh-frozen, paired cadaveric feet were dissected to expose the dorsal region. A registration marker triad consisting of three screws was fixed to the first cuneiform and the second metatarsal. A digitizer was utilized to record the three-dimensional positions of the registration markers and their displacement in test conditions before and after cutting of the Lisfranc ligament and after stabilization of the joint with either a suture button or a cannulated screw. The first and second cuneiforms and their metatarsals were removed, and the ligament attachment sites were digitized. Displacement at the Lisfranc ligament and the three-dimensional positions of the bones were determined. Results: Loading with the Lisfranc ligament cut resulted in displacement that was significantly different from that after screw fixation (p = 0.0001), with a difference between means of 1.2 mm. Likewise, loading with the Lisfranc ligament cut resulted in a displacement that was significantly different from that after suture-button fixation (p = 0.0008), with a difference between means of 1.00 mm. No significant difference in displacement was found between specimens fixed with the suture button and those fixed with the screw. Conclusions: Suture-button fixation can provide stability similar to that provided by screw fixation in cadaver specimens after isolated transection of the Lisfranc ligament. Clinical Relevance: Fixation with a suture button may be an acceptable alternative to screw fixation in the treatment of isolated Lisfranc ligament injuries, avoiding subsequent surgery to remove the hardware prior to weight-bearing.


  • A Minimally Disruptive Model and Three-Dimensional Evaluation of Lisfranc Joint Diastasis

    by Vinod K Panchbhavi, Clark R Andersen, Santaram Vallurupalli, Jinping Yang

    Do not represent a subset of injuries that cause subtle or limited disruption at the Lisfranc joint. The purpose of this study was to create a model with the minimum amount of ligamentous disruption and loading necessary to consistently observe diastasis at the Lisfranc joint....