Carsten Maik Naumann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carsten Maik Naumann has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Klaus-Peter Jünemann
Universitätsklinikum Schleswig-Holstein, Campus Kiel
3 shared publications - Alexey V. Aksenov
Department of Urology and Pediatric Urology, University Hospital Schleswig Holstein, Kiel, Germany
2 shared publications C. van der Horst
Klinik für Urologie und Kinderurologie, Campus Kiel, Universitätsklinikum Schleswig-Holstein, Arnold-Heller-Straße 3, 24105, Kiel, Deutschland
2 shared publications- Daniar Osmonov
Department of Urology, University Medical Center Schleswig-Holstein, Campus Lübeck, Germany
2 shared publications K.-P. Jünemann
Klinik für Urologie und Kinderurologie, Universitätsklinikum Schleswig Holstein, Campus Kiel, Kiel, Deutschland
2 shared publicationsKlaus-Peter Jünemann
Department of Urology and Pediatric Urology, University Hospital Schleswig Holstein, Kiel, Germany
2 shared publications
Latest Publications
- 1 April 2018
- Published by Springer Nature in Der Urologe
- Vol. 57 (4) , 408-412
Epidemiology of penile cancer
Penile cancer represents a rarity in daily clinical practice. The aim is to identify global differences concerning the incidence, social and risk factors. The past and current epidemiologic literature is analyzed concerning incidence rates and risk factors. The latter are discussed concerning their potential with regard to disease prevention. Globally, incidence rates of penile cancer range from low to nonexistent. Distinct differences are found when comparing industrialized countries with emerging and developing countries. Phimosis seems to be a crucial risk factor in the formation of penile cancer. Additionally, chronic inflammatory diseases of the penis were found to be associated with a higher risk. Preventive measures should be considered in relation to the rarity of the disease, especially in the valuation of circumcision during early childhood. Regular clinical examination of the penis is a sensible measure of early detection.
- 1 April 2018
- Published by Springer Nature in Der Urologe
- Vol. 57 (4) , 408-412
Epidemiology of penile cancer
Penile cancer represents a rarity in daily clinical practice. The aim is to identify global differences concerning the incidence, social and risk factors. The past and current epidemiologic literature is analyzed concerning incidence rates and risk factors. The latter are discussed concerning their potential with regard to disease prevention. Globally, incidence rates of penile cancer range from low to nonexistent. Distinct differences are found when comparing industrialized countries with emerging and developing countries. Phimosis seems to be a crucial risk factor in the formation of penile cancer. Additionally, chronic inflammatory diseases of the penis were found to be associated with a higher risk. Preventive measures should be considered in relation to the rarity of the disease, especially in the valuation of circumcision during early childhood. Regular clinical examination of the penis is a sensible measure of early detection.
- 1 March 2018
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 36 (3) , 92.e17-92.e24
Evaluation of the diagnostic value of preoperative sentinel lymph node (SLN) imaging in penile carcinoma patients without palpable inguinal lymph nodes via single photon emission computed tomography/computed tomography (SPECT/CT) as compared to planar scintigraphy
- 1 March 2018
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 36 (3) , 92.e17-92.e24
Evaluation of the diagnostic value of preoperative sentinel lymph node (SLN) imaging in penile carcinoma patients without palpable inguinal lymph nodes via single photon emission computed tomography/computed tomography (SPECT/CT) as compared to planar scintigraphy
- Open Access
- 9 November 2017
- Published by Springer Nature in BMC Research Notes
- Vol. 10 (1) , 579
Application of ultrasound imaging biomarkers (HistoScanning™) improves staging reliability of prostate biopsies
Imaging biomarkers like HistoScanning™ augment the informative value of ultrasound. Analogue image-guidance might improve the diagnostic accuracy of prostate biopsies and reduce misclassifications in preoperative staging and grading. Comparison of 77 image-guided versus 88 systematic prostate biopsies revealed that incorrect staging and Gleason misclassification occurs less frequently in image-guided than in systematic prostate biopsies. Systematic prostate biopsies (4–36 cores, median 12 cores) tended to detect predominantly unilateral tumors (39% sensitivity, 90.9% specificity, 17.5% negative and 50% positive predictive values). Bilateral tumors were diagnosed more frequently by image-guided prostate biopsies (87.9% sensitivity, 72.7% specificity, 50% negative and 96.8% positive predictive values). Regarding the detection of lesions with high Gleason scores ≥ 3 + 4, systematic prostate and image-guided biopsies yielded sensitivity and specificity rates of 66.7% vs 93.5%, 86% vs 64.5%, as well as negative and positive predictive values of 71.2% vs 87%, and 83.3% vs 79.6%, respectively. Potential reason for systematic prostate biopsies missing the correct laterality and the correct Gleason score was a mismatch between the biopsy template and the respective pathological cancer localization. This supports the need for improved detection techniques such as ultrasound imaging biomarkers and image-adapted biopsies.
- 9 November 2017
- Published by Springer Nature in BMC Research Notes
- Vol. 10 (1) , 579
Open AccessApplication of ultrasound imaging biomarkers (HistoScanning™) improves staging reliability of prostate biopsies
Imaging biomarkers like HistoScanning™ augment the informative value of ultrasound. Analogue image-guidance might improve the diagnostic accuracy of prostate biopsies and reduce misclassifications in preoperative staging and grading. Comparison of 77 image-guided versus 88 systematic prostate biopsies revealed that incorrect staging and Gleason misclassification occurs less frequently in image-guided than in systematic prostate biopsies. Systematic prostate biopsies (4–36 cores, median 12 cores) tended to detect predominantly unilateral tumors (39% sensitivity, 90.9% specificity, 17.5% negative and 50% positive predictive values). Bilateral tumors were diagnosed more frequently by image-guided prostate biopsies (87.9% sensitivity, 72.7% specificity, 50% negative and 96.8% positive predictive values). Regarding the detection of lesions with high Gleason scores ≥ 3 + 4, systematic prostate and image-guided biopsies yielded sensitivity and specificity rates of 66.7% vs 93.5%, 86% vs 64.5%, as well as negative and positive predictive values of 71.2% vs 87%, and 83.3% vs 79.6%, respectively. Potential reason for systematic prostate biopsies missing the correct laterality and the correct Gleason score was a mismatch between the biopsy template and the respective pathological cancer localization. This supports the need for improved detection techniques such as ultrasound imaging biomarkers and image-adapted biopsies.
- Open Access
- 7 September 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-16
A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
- 7 September 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-16
Open AccessA study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
- Open Access
- 6 September 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 56
Cancer-specific and overall survival in patients with recurrent prostate cancer who underwent salvage extended pelvic lymph node dissection
The aim was to evaluate cancer-specific survival (CSS) and overall survival (OS) in patients with prostate cancer (PCa) recurrence who underwent salvage extended pelvic lymph node dissection (ePLND), taking into consideration pre- and postoperative androgen deprivation therapy (ADT). Salvage ePLND was performed in a cohort of 54 patients with PCa recurrence, and data from 45 patients were analyzed. The indications for salvage ePLND were biochemical recurrence (BCR) of PCa and suspect findings on 11C-choline PET/CT. PSA-level, biochemical response (BR), duration of biochemical recurrence freedom (BCRF), number of metastases, OS and CSS were analyzed retrospectively. The average follow-up was 42.7 ± 20.8 months. Thirty-three patients (73.3 %, 95 % CI: 60.5–83.6 %) achieved BCRF during follow-up. The mean BCRF-period was 31.4 ± 19.7 months. CSS and OS were both 91.7 % ± 4.8 % (3-year survival) and 80.6 ± 8.6 % (5-year survival). Twenty-four patients (53.3 %, 95 % CI: 40.0–66.3 %) with castration-resistant PCa (CRPC) responded again to ADT after salvage ePLND. Salvage ePLND for selected patients with BCR and clinically recurrent nodal disease can achieve an immediate complete PSA response (i. e. BCRF) in nearly half of the patients. Patients with CRPC responded again to ADT after ePLND. Multicenter prospective studies with a control group are needed.
- 6 September 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 56
Open AccessCancer-specific and overall survival in patients with recurrent prostate cancer who underwent salvage extended pelvic lymph node dissection
The aim was to evaluate cancer-specific survival (CSS) and overall survival (OS) in patients with prostate cancer (PCa) recurrence who underwent salvage extended pelvic lymph node dissection (ePLND), taking into consideration pre- and postoperative androgen deprivation therapy (ADT). Salvage ePLND was performed in a cohort of 54 patients with PCa recurrence, and data from 45 patients were analyzed. The indications for salvage ePLND were biochemical recurrence (BCR) of PCa and suspect findings on 11C-choline PET/CT. PSA-level, biochemical response (BR), duration of biochemical recurrence freedom (BCRF), number of metastases, OS and CSS were analyzed retrospectively. The average follow-up was 42.7 ± 20.8 months. Thirty-three patients (73.3 %, 95 % CI: 60.5–83.6 %) achieved BCRF during follow-up. The mean BCRF-period was 31.4 ± 19.7 months. CSS and OS were both 91.7 % ± 4.8 % (3-year survival) and 80.6 ± 8.6 % (5-year survival). Twenty-four patients (53.3 %, 95 % CI: 40.0–66.3 %) with castration-resistant PCa (CRPC) responded again to ADT after salvage ePLND. Salvage ePLND for selected patients with BCR and clinically recurrent nodal disease can achieve an immediate complete PSA response (i. e. BCRF) in nearly half of the patients. Patients with CRPC responded again to ADT after ePLND. Multicenter prospective studies with a control group are needed.
- Open Access
- 2 August 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 1-10
10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure
The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany – the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.
- 2 August 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 1-10
Open Access10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure
The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany – the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.
- 10 October 2015
- Published by Springer Nature in Der Urologe
- Vol. 55 (5) , 641-644
Langzeitergebnisse der Sentinel-Lymphknotendiagnostik beim Peniskarzinom
- 10 October 2015
- Published by Springer Nature in Der Urologe
- Vol. 55 (5) , 641-644
Langzeitergebnisse der Sentinel-Lymphknotendiagnostik beim Peniskarzinom
- 1 September 2015
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 33 (9) , 389.e9-389.e14
Reliability of dynamic sentinel node biopsy combined with ultrasound-guided removal of sonographically suspicious lymph nodes as a diagnostic approach in patients with penile cancer with palpable inguinal lymph nodes
- 1 September 2015
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 33 (9) , 389.e9-389.e14
Reliability of dynamic sentinel node biopsy combined with ultrasound-guided removal of sonographically suspicious lymph nodes as a diagnostic approach in patients with penile cancer with palpable inguinal lymph nodes
- Open Access
- 30 July 2015
- Published by Springer Nature in BMC Urology
- Vol. 15 (1) , 76
Computer-aided transrectal ultrasound: does prostate HistoScanning™ improve detection performance of prostate cancer in repeat biopsies?
An imaging tool providing reliable prostate cancer (PCa) detection and localization is necessary to improve common diagnostic pathway with ultrasound targeted biopsies. To determine the performance of transrectal ultrasound (TRUS) augmented by prostate HistoScanningTM analysis (PHS) we investigated the detection of prostate cancer (PCa) foci in repeat prostate biopsies (Bx). 97 men with a mean age of 66.2 (44 – 82) years underwent PHS augmented TRUS analysis prior to a repeat Bx. Three PHS positive foci were defined in accordance with 6 bilateral prostatic sectors. Targeted Bx (tBx) limited to PHS positive foci and a systematic 14-core backup Bx (sBx) were taken. Results were correlated to biopsy outcome. Sensitivity, specificity, predictive accuracy, negative predictive value (NPV) and positive predictive value (PPV) were calculated. PCa was found in 31 of 97 (32 %) patients. Detection rate in tBx was significantly higher (p < .001). Detection rate in tBx and sBx did not differ on patient level(p ≥ 0.7). PHS sensitivity, specificity, predictive accuracy, PPV and NPV were 45 %, 83 %, 80 %, 19 % and 95 %, respectively. PHS augmented TRUS identifies abnormal prostatic tissue. Although sensitivity and PPV for PCa are low, PHS information facilitates Bx targeting to vulnerable foci and results in a higher cancer detection rate. PHS targeted Bx should be considered in patients at persistent risk of PCa.
- 30 July 2015
- Published by Springer Nature in BMC Urology
- Vol. 15 (1) , 76
Open AccessComputer-aided transrectal ultrasound: does prostate HistoScanning™ improve detection performance of prostate cancer in repeat biopsies?
An imaging tool providing reliable prostate cancer (PCa) detection and localization is necessary to improve common diagnostic pathway with ultrasound targeted biopsies. To determine the performance of transrectal ultrasound (TRUS) augmented by prostate HistoScanningTM analysis (PHS) we investigated the detection of prostate cancer (PCa) foci in repeat prostate biopsies (Bx). 97 men with a mean age of 66.2 (44 – 82) years underwent PHS augmented TRUS analysis prior to a repeat Bx. Three PHS positive foci were defined in accordance with 6 bilateral prostatic sectors. Targeted Bx (tBx) limited to PHS positive foci and a systematic 14-core backup Bx (sBx) were taken. Results were correlated to biopsy outcome. Sensitivity, specificity, predictive accuracy, negative predictive value (NPV) and positive predictive value (PPV) were calculated. PCa was found in 31 of 97 (32 %) patients. Detection rate in tBx was significantly higher (p < .001). Detection rate in tBx and sBx did not differ on patient level(p ≥ 0.7). PHS sensitivity, specificity, predictive accuracy, PPV and NPV were 45 %, 83 %, 80 %, 19 % and 95 %, respectively. PHS augmented TRUS identifies abnormal prostatic tissue. Although sensitivity and PPV for PCa are low, PHS information facilitates Bx targeting to vulnerable foci and results in a higher cancer detection rate. PHS targeted Bx should be considered in patients at persistent risk of PCa.
- 11 April 2013
- Published by Springer Nature in Der Urologe
- Vol. 52 (10) , 1447-1450
Sentinel-Lymphknotenbiopsie beim Peniskarzinom
- 11 April 2013
- Published by Springer Nature in Der Urologe
- Vol. 52 (10) , 1447-1450
Sentinel-Lymphknotenbiopsie beim Peniskarzinom