Klaus-Peter Jünemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Klaus-Peter Jünemann has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Daniar Osmonov
Department of Urology, University Medical Center Schleswig-Holstein, Campus Lübeck, Germany
4 shared publications - Carsten Maik Naumann
Department of Urology and Pediatric Urology, University Hospital Schleswig Holstein, Kiel, Germany
3 shared publications - Claudius Hamann
Universitätsklinikum Schleswig-Holstein, Campus Kiel
3 shared publications - Maaz Zuhayra
Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Campus Kiel, Karl Lennert Cancer Center North, Kiel, Germany
2 shared publications - Marlies Marx
Department of Nuclear Medicine, Molecular Imaging Diagnostics and Therapy, University Hospital Schleswig Holstein, Kiel, Germany
2 shared publications - Michael Jüptner
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
2 shared publications
Latest Publications
- 19 July 2023
- Published by Springer Nature
- p. 1861-1875
Penisprothesen
- 19 July 2023
- Published by Springer Nature
- p. 85-95
Zugangswege Abdomen und Retroperitoneum
- 20 December 2022
- Published by Springer Nature
- p. 1-15
Penisprothesen
- 9 November 2022
- Published by Springer Nature
- p. 1-11
Zugangswege Abdomen und Retroperitoneum
- Open Access
Detection of Cancer Mutations by Urine Liquid Biopsy as a Potential Tool in the Clinical Management of Bladder Cancer Patients
The standard diagnostic and follow-up examination for bladder cancer is diagnostic cystoscopy, an invasive test that requires compliance for a long period. Urine cytology and recent biomarkers come short of replacing cystoscopy. Urine liquid biopsy promises to solve this problem and potentially allows early detection, evaluation of treatment efficacy, and surveillance. A previous study reached 52–68% sensitivity using small-panel sequencing but could increase sensitivity to 68–83% by adding aneuploidy and promoter mutation detection. Here, we explore whether a large 127-gene panel alone is sufficient to detect tumor mutations in urine from bladder cancer patients. We recruited twelve bladder cancer patients, obtained preoperative and postoperative urine samples, and successfully analyzed samples from eleven patients. In ten patients, we found at least one mutation in bladder-cancer-associated genes, i.e., a promising sensitivity of 91%. In total, we identified 114 variants, of which 90 were predicted as nonbenign, 30% were associated with cancer, and 13% were actionable according to the CIViC database. Sanger sequencing of the patients’ formalin-fixed, paraffin-embedded (FFPE) tumor tissues confirmed the findings. We concluded that incorporating urine liquid biopsy is a promising strategy in the management of bladder cancer patients.
Open AccessDetection of Cancer Mutations by Urine Liquid Biopsy as a Potential Tool in the Clinical Management of Bladder Cancer Patients
The standard diagnostic and follow-up examination for bladder cancer is diagnostic cystoscopy, an invasive test that requires compliance for a long period. Urine cytology and recent biomarkers come short of replacing cystoscopy. Urine liquid biopsy promises to solve this problem and potentially allows early detection, evaluation of treatment efficacy, and surveillance. A previous study reached 52–68% sensitivity using small-panel sequencing but could increase sensitivity to 68–83% by adding aneuploidy and promoter mutation detection. Here, we explore whether a large 127-gene panel alone is sufficient to detect tumor mutations in urine from bladder cancer patients. We recruited twelve bladder cancer patients, obtained preoperative and postoperative urine samples, and successfully analyzed samples from eleven patients. In ten patients, we found at least one mutation in bladder-cancer-associated genes, i.e., a promising sensitivity of 91%. In total, we identified 114 variants, of which 90 were predicted as nonbenign, 30% were associated with cancer, and 13% were actionable according to the CIViC database. Sanger sequencing of the patients’ formalin-fixed, paraffin-embedded (FFPE) tumor tissues confirmed the findings. We concluded that incorporating urine liquid biopsy is a promising strategy in the management of bladder cancer patients.
- Open Access
Impact of Acoustic and Interactive Disruptive Factors during Robot-Assisted Surgery—A Virtual Surgical Training Model
The use of virtual reality trainers for teaching minimally invasive surgical techniques has been established for a long time in conventional laparoscopy as well as robotic surgery. The aim of the present study was to evaluate the impact of reproducible disruptive factors on the surgeon’s work. In a cross-sectional investigation, surgeons were tested with regard to the impact of different disruptive factors when doing exercises on a robotic-surgery simulator (Mimic Flex VRTM). Additionally, we collected data about the participants’ professional experience, gender, age, expertise in playing an instrument, and expertise in playing video games. The data were collected during DRUS 2019 (Symposium of the German Society for Robot-assisted Urology). Forty-two surgeons attending DRUS 2019 were asked to participate in a virtual robotic stress training unit. The surgeons worked in various specialties (visceral surgery, gynecology, and urology) and had different levels of expertise. The time taken to complete the exercise (TTCE), the final score (FSC), and blood loss (BL) were measured. In the basic exercise with an interactive disruption, TTCE was significantly longer (p < 0.01) and FSC significantly lower (p < 0.05). No significant difference in TTCE, FSC, or BL was noted in the advanced exercise with acoustic disruption. Performance during disruption was not dependent on the level of surgical experience, gender, age, expertise in playing an instrument, or playing video games. A positive correlation was registered between self-estimation and surgical experience. Interactive disruptions have a greater impact on the performance of a surgeon than acoustic ones. Disruption affects the performance of experienced as well as inexperienced surgeons. Disruption in daily surgery should be evaluated and minimized in the interest of the patient’s safety.
Open AccessImpact of Acoustic and Interactive Disruptive Factors during Robot-Assisted Surgery—A Virtual Surgical Training Model
The use of virtual reality trainers for teaching minimally invasive surgical techniques has been established for a long time in conventional laparoscopy as well as robotic surgery. The aim of the present study was to evaluate the impact of reproducible disruptive factors on the surgeon’s work. In a cross-sectional investigation, surgeons were tested with regard to the impact of different disruptive factors when doing exercises on a robotic-surgery simulator (Mimic Flex VRTM). Additionally, we collected data about the participants’ professional experience, gender, age, expertise in playing an instrument, and expertise in playing video games. The data were collected during DRUS 2019 (Symposium of the German Society for Robot-assisted Urology). Forty-two surgeons attending DRUS 2019 were asked to participate in a virtual robotic stress training unit. The surgeons worked in various specialties (visceral surgery, gynecology, and urology) and had different levels of expertise. The time taken to complete the exercise (TTCE), the final score (FSC), and blood loss (BL) were measured. In the basic exercise with an interactive disruption, TTCE was significantly longer (p < 0.01) and FSC significantly lower (p < 0.05). No significant difference in TTCE, FSC, or BL was noted in the advanced exercise with acoustic disruption. Performance during disruption was not dependent on the level of surgical experience, gender, age, expertise in playing an instrument, or playing video games. A positive correlation was registered between self-estimation and surgical experience. Interactive disruptions have a greater impact on the performance of a surgeon than acoustic ones. Disruption affects the performance of experienced as well as inexperienced surgeons. Disruption in daily surgery should be evaluated and minimized in the interest of the patient’s safety.
- Open Access
- 18 August 2017
- Published by Springer Nature in Radiation Oncology
- Vol. 12 (1) , 1-7
Hypo-fractionated SBRT for localized prostate cancer: a German bi-center single treatment group feasibility trial
For prostate cancer treatment, treatment options with minimal side effects are desired. External beam radiation therapy (EBRT) is non-invasive, standard of care and delivered in either conventional fractionation over 8 weeks or with moderate hypo-fractionation over about 5 weeks. Recent advances in radiotherapy technology have made extreme hypo-fractionated stereotactic body radiation therapy (SBRT) of prostate cancer feasible, which has not yet been introduced as a standard treatment method in Germany. Initial results from other countries are promising, but long-term results are not yet available. The aim of this study is to investigate feasibility and effectiveness of SBRT for prostate cancer in Germany. This German bi-center single group trial (HYPOSTAT) is designed to evaluate feasibility and effectiveness, as measured by toxicity and PSA-response, respectively, of an extreme hypo-fractionated SBRT regimen with five fractions of 7 Gy in treatment of localized low and intermediate risk prostate cancer. The target volume includes the prostate with or without the base of seminal vesicles depending on risk stratification and uncertainty margins that are kept at 3–5 mm. SBRT treatment is delivered with the robotic CyberKnife system, which was recently introduced in Germany. Acute and late toxicity after one year will be evaluated according to Common Terminology Criteria for Adverse Events (CTCAE v. 4.0), Radiation Therapy Oncology Group (RTOG) and International Prostate Symptom Score (IPSS) Scores. The quality of life will be assessed before and after treatment with the EORTC QLQ C30 questionnaire. Hypothesizing that the proportion of patients with grade 2 side effects or higher is less or equal than 2.8%, thus markedly lower than the standard EBRT percentage (17.5%), the recruitment target is 85 patients. The HYPOSTAT trial aims at demonstrating short term feasibility of extreme hypo-fractioned SBRT for the treatment of prostate cancer and might be used as the pilot study for a multi-center multi-platform or for randomized-controlled trials comparing conventional radiotherapy with SBRT for localized prostate cancer in the future. The study concept of patient enrollment, follow up and evaluation by multiple public university clinics and actual patient treatment in dedicated private radiosurgery practices with high-tech radiation equipment is unique for clinical trials. The study is ongoing and currently recruiting patients. Registration number: NCT02635256 ( clinicaltrials.gov ). Registered 8 December 2015.
- 18 August 2017
- Published by Springer Nature in Radiation Oncology
- Vol. 12 (1) , 1-7
Open AccessHypo-fractionated SBRT for localized prostate cancer: a German bi-center single treatment group feasibility trial
For prostate cancer treatment, treatment options with minimal side effects are desired. External beam radiation therapy (EBRT) is non-invasive, standard of care and delivered in either conventional fractionation over 8 weeks or with moderate hypo-fractionation over about 5 weeks. Recent advances in radiotherapy technology have made extreme hypo-fractionated stereotactic body radiation therapy (SBRT) of prostate cancer feasible, which has not yet been introduced as a standard treatment method in Germany. Initial results from other countries are promising, but long-term results are not yet available. The aim of this study is to investigate feasibility and effectiveness of SBRT for prostate cancer in Germany. This German bi-center single group trial (HYPOSTAT) is designed to evaluate feasibility and effectiveness, as measured by toxicity and PSA-response, respectively, of an extreme hypo-fractionated SBRT regimen with five fractions of 7 Gy in treatment of localized low and intermediate risk prostate cancer. The target volume includes the prostate with or without the base of seminal vesicles depending on risk stratification and uncertainty margins that are kept at 3–5 mm. SBRT treatment is delivered with the robotic CyberKnife system, which was recently introduced in Germany. Acute and late toxicity after one year will be evaluated according to Common Terminology Criteria for Adverse Events (CTCAE v. 4.0), Radiation Therapy Oncology Group (RTOG) and International Prostate Symptom Score (IPSS) Scores. The quality of life will be assessed before and after treatment with the EORTC QLQ C30 questionnaire. Hypothesizing that the proportion of patients with grade 2 side effects or higher is less or equal than 2.8%, thus markedly lower than the standard EBRT percentage (17.5%), the recruitment target is 85 patients. The HYPOSTAT trial aims at demonstrating short term feasibility of extreme hypo-fractioned SBRT for the treatment of prostate cancer and might be used as the pilot study for a multi-center multi-platform or for randomized-controlled trials comparing conventional radiotherapy with SBRT for localized prostate cancer in the future. The study concept of patient enrollment, follow up and evaluation by multiple public university clinics and actual patient treatment in dedicated private radiosurgery practices with high-tech radiation equipment is unique for clinical trials. The study is ongoing and currently recruiting patients. Registration number: NCT02635256 ( clinicaltrials.gov ). Registered 8 December 2015.
- Open Access
- 7 September 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-16
A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
- 7 September 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-16
Open AccessA study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
- Open Access
- 2 August 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 1-10
10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure
The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany – the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.
- 2 August 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 1-10
Open Access10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure
The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany – the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.
- Open Access
- 30 July 2015
- Published by Springer Nature in BMC Urology
- Vol. 15 (1) , 76
Computer-aided transrectal ultrasound: does prostate HistoScanning™ improve detection performance of prostate cancer in repeat biopsies?
An imaging tool providing reliable prostate cancer (PCa) detection and localization is necessary to improve common diagnostic pathway with ultrasound targeted biopsies. To determine the performance of transrectal ultrasound (TRUS) augmented by prostate HistoScanningTM analysis (PHS) we investigated the detection of prostate cancer (PCa) foci in repeat prostate biopsies (Bx). 97 men with a mean age of 66.2 (44 – 82) years underwent PHS augmented TRUS analysis prior to a repeat Bx. Three PHS positive foci were defined in accordance with 6 bilateral prostatic sectors. Targeted Bx (tBx) limited to PHS positive foci and a systematic 14-core backup Bx (sBx) were taken. Results were correlated to biopsy outcome. Sensitivity, specificity, predictive accuracy, negative predictive value (NPV) and positive predictive value (PPV) were calculated. PCa was found in 31 of 97 (32 %) patients. Detection rate in tBx was significantly higher (p < .001). Detection rate in tBx and sBx did not differ on patient level(p ≥ 0.7). PHS sensitivity, specificity, predictive accuracy, PPV and NPV were 45 %, 83 %, 80 %, 19 % and 95 %, respectively. PHS augmented TRUS identifies abnormal prostatic tissue. Although sensitivity and PPV for PCa are low, PHS information facilitates Bx targeting to vulnerable foci and results in a higher cancer detection rate. PHS targeted Bx should be considered in patients at persistent risk of PCa.
- 30 July 2015
- Published by Springer Nature in BMC Urology
- Vol. 15 (1) , 76
Open AccessComputer-aided transrectal ultrasound: does prostate HistoScanning™ improve detection performance of prostate cancer in repeat biopsies?
An imaging tool providing reliable prostate cancer (PCa) detection and localization is necessary to improve common diagnostic pathway with ultrasound targeted biopsies. To determine the performance of transrectal ultrasound (TRUS) augmented by prostate HistoScanningTM analysis (PHS) we investigated the detection of prostate cancer (PCa) foci in repeat prostate biopsies (Bx). 97 men with a mean age of 66.2 (44 – 82) years underwent PHS augmented TRUS analysis prior to a repeat Bx. Three PHS positive foci were defined in accordance with 6 bilateral prostatic sectors. Targeted Bx (tBx) limited to PHS positive foci and a systematic 14-core backup Bx (sBx) were taken. Results were correlated to biopsy outcome. Sensitivity, specificity, predictive accuracy, negative predictive value (NPV) and positive predictive value (PPV) were calculated. PCa was found in 31 of 97 (32 %) patients. Detection rate in tBx was significantly higher (p < .001). Detection rate in tBx and sBx did not differ on patient level(p ≥ 0.7). PHS sensitivity, specificity, predictive accuracy, PPV and NPV were 45 %, 83 %, 80 %, 19 % and 95 %, respectively. PHS augmented TRUS identifies abnormal prostatic tissue. Although sensitivity and PPV for PCa are low, PHS information facilitates Bx targeting to vulnerable foci and results in a higher cancer detection rate. PHS targeted Bx should be considered in patients at persistent risk of PCa.