Robert L. Stamper
Research Subjects
Research Interests
Robert L. Stamper has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Michelle Nee
2 shared publicationsChristoph Kniestedt
Department of Ophthalmology, University of California-San Francisco, 10 Kirkham Street, San Francisco, CA 94143, USA
1 shared publication- Christoph Kniestedt
Department of Ophthalmology, University of California, San Francisco, CA, USA
1 shared publication Hartmut Kanngiesser
1 shared publication
Latest Publications
- 1 November 2006
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 124 (11) , 1664
Applanation Area in Goldmann Applanation Tonometry—Reply
In reply We thank Dr Tesser for his observations. He is correct that the precise diameter of 3.06 mm allows the easy conversion of 1 g of force (1 pond) to 10 mm Hg. However, we do disagree that a range of diameters would allow a balance between the effect of corneal elasticity and the effect of the capillary attraction of tears. In their paper,1Goldmann and Schmidt show Figure 8 (page 232) which clearly demonstrates a linear relationship between applanation diameter and corneal rigidity forces for diameters greater than 3mm with a slope different than 0. The graph also shows that the behaviour is different for each eye. Therefore, the corneal rigidity and capillary attraction forces balance each other only where this line for an individual eye crosses 0 at exactly 3.06 mm applanation diameter.
- 1 November 2006
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 124 (11) , 1664
Applanation Area in Goldmann Applanation Tonometry—Reply
In reply We thank Dr Tesser for his observations. He is correct that the precise diameter of 3.06 mm allows the easy conversion of 1 g of force (1 pond) to 10 mm Hg. However, we do disagree that a range of diameters would allow a balance between the effect of corneal elasticity and the effect of the capillary attraction of tears. In their paper,1Goldmann and Schmidt show Figure 8 (page 232) which clearly demonstrates a linear relationship between applanation diameter and corneal rigidity forces for diameters greater than 3mm with a slope different than 0. The graph also shows that the behaviour is different for each eye. Therefore, the corneal rigidity and capillary attraction forces balance each other only where this line for an individual eye crosses 0 at exactly 3.06 mm applanation diameter.
- 1 May 2006
- Published by BMJ in British Journal of Ophthalmology
- Vol. 90 (5) , 523
Mozart in AVF testing
An improvement in our visual field testing process would be most welcome
- 1 May 2006
- Published by BMJ in British Journal of Ophthalmology
- Vol. 90 (5) , 523
Mozart in AVF testing
An improvement in our visual field testing process would be most welcome
- 1 September 2004
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 122 (9) , 1287-1293
Dynamic Contour Tonometry
Research from JAMA Ophthalmology — Dynamic Contour Tonometry — A Comparative Study on Human Cadaver Eyes
- 1 September 2004
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 122 (9) , 1287-1293
Dynamic Contour Tonometry
Research from JAMA Ophthalmology — Dynamic Contour Tonometry — A Comparative Study on Human Cadaver Eyes