JCJohn T. Capo

John T. Capo

*This is an algorithmically generated author record based on publicly available information.

John T. Capo has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • Ben Shamian

    Woodhull Medical Center, Brooklyn, NY, USA

    7 shared publications
  • Bryan G. Beutel

    Department of Primary Care, Kansas City University College of Medicine, Kansas City, Missouri, United States

    2 shared publications
  • Frank A. Liporace

    Division of Orthopaedic Trauma & Adult Reconstruction, Department of Orthopaedic Surgery, Cooperman Barnabas Medical Center, Jersey City Medical Center, RWJBarnabas Health Livingston, Jersey City, NJ, United States

    2 shared publications
  • Frank Liporace

    Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, USA

    2 shared publications
  • Ramces Francisco

    Division of Hand and Microvascular Surgery, Department of Orthopaedic Surgery, Rutgers New Jersey Medical School, Newark, USA

    2 shared publications
  • Richard M. Hinds

    Department of Orthopaedic Surgery, New York University Hospital for Joint Diseases

    2 shared publications

Latest Publications

  • Radial Shaft Convergence in Distal Radius Fractures: Diagnosis and Treatment

    by Daniel Tordjman, Richard M. Hinds, S. Steven Yang, John T. Capo

    Radial shaft convergence in distal radius fractures is often misdiagnosed. This common deformation is often associated with a radial translation of the distal fragment. This parameter has to be corrected because of the increased risk of distal radioulnar joint instability due to detensioning of the distal interosseous membrane if there is an associated triangular fibrocartilage complex lesion. A new radiologic sign for diagnosis of proximal radius convergence during distal radius fracture is presented as well as technical tips for correction of this deformity.


  • Orthopedic Oncology Caseload Among Orthopedic Surgery Residents

    by Richard M. Hinds, Timothy B. Rapp, John T. Capo

    Despite educational focus regarding orthopedic oncology during residency, assessment of resident orthopedic oncology caseload has not been performed. The purpose of this study was to evaluate orthopedic oncology caseload trends and variation among residents. The Accreditation Council for Graduate Medical Education case log reports for orthopedic surgery residents were reviewed for graduating years 2007 to 2013. Trends in orthopedic oncology cases and variation in the median number of cases performed by residents in the 90th, 50th, and 10th percentiles of caseload were evaluated. The proportion of orthopedic oncology caseload among all cases performed by residents increased significantly (P = 0.005) from 2007 to 2013. Likewise, the mean number of adult (P = 0.002), pediatric (P = 0.003), and total orthopedic oncology cases increased significantly (P = 0.002). On average, residents in the 90th, 50th, and 10th percentiles performed 83, 28, and 3 cases, respectively. The current study demonstrates a significant increase in adult, pediatric, and total orthopedic oncology caseload. There is also evidence of substantial caseload variation among residents. Caseload variation may influence the education and technical proficiency of orthopedic residents.


    • 1 December 2015
      • Vol. 73  (4) , 249-56

    Comparative Readability of Shoulder and Elbow Patient Education Materials within Orthopaedic Websites.

    by Bryan G Beutel, Natalie R Danna, Eitan Melamed, John T Capo

    There is growing concern that the readability of online orthopaedic patient education materials are too difficult for the general public to fully understand. It is recommended that this information be at the sixth grade reading level or lower. This study compared the readability of shoulder and elbow education articles from the American Academy of Orthopaedic Surgeons (AAOS) and American Society for Surgery of the Hand (ASSH) websites. Seventy-six patient education articles from the AAOS and ASSH concerning shoulder and elbow disorders were evaluated. Each article was assessed for the number of years since its last update, word count, percentage of passive sentences, Flesch Reading Ease score, Flesch-Kincaid grade level, Simple Measure of Gobbledygook (SMOG) grade, and New Dale-Chall grade level. Only one article was at or below the sixth grade reading level. The AAOS and ASSH articles had the following respective scores: a mean Flesch Reading Ease score of 54.3 and 51.8, Flesch-Kincaid grade level of 9.4 and 10.3, SMOG grade of 8.5 and 9.4, and New Dale-Chall grade of 10.4 and 11.0. Articles from the AAOS were longer (p < 0.001), had a lower percentage of passive sentences (p < 0.001), and were more recently updated (p = 0.02) than their ASSH counterparts. Higher percentages of passive sentences were found to correlate with more difficult readability. Patient education materials regarding the shoulder and elbow on the AAOS and ASSH websites have readability scores above the recommended reading level. These may be too challenging for the majority of patients to read and consequently serve as a barrier to proper patient education. Reducing the percentage of passive sentences may serve as a novel target for improving readability.


  • Open Access

    Novel Use of Synthetic Acellular Dermal Matrix for Coverage of a Tibial Defect Following Resection of an Osteochondroma

    by Ben Shamian, Richard M. Hinds, John T. Capo

    The application of an artificial dermal matrix (Integra Life Sciences, Plainsboro, NJ) in the management of substantial burn injuries has been extensively documented. Use of an artificial dermal matrix has resulted in excellent outcomes and is free of the morbidity associated with harvesting free-tissue flaps. However, coverage of bony defects where the periosteum has been removed is often challenging. In the current report, we present a case wherein the use of an acellular synthetic dermis combined with split-thickness skin grafting resulted in successful coverage of a tibial defect following resection of an osteochondroma.


  • Open Access

    Anatomic variant of the inferior lateral cutaneous branch of the radial nerve during the posterior approach to the humerus: a case report

    by Li Sun, Brian K Park, Salil Gupta, John T Capo, Richard S Yoon, Frank A Liporace

    Iatrogenic injury during the posterior approach to the humerus during operative fixation is not an uncommon occurrence. A comprehensive understanding of the normal anatomy and its variants is of paramount importance in order to avoid such injury. Typically, the inferior lateral cutaneous branch of the radial nerve originates towards the distal end of the humerus at the inferior portion of the spiral groove. Here, we report an important variant of this nerve, which originated significantly more proximal than expected, further emphasizing the importance of identification, dissection and protection of the radial nerve and its major branches.


  • Open Access

    Fracture pattern characteristics and associated injuries of high-energy, large fragment, partial articular radial head fractures: a preliminary imaging analysis

    by John T. Capo, Ben Shamian, Ramces Francisco, Virak Tan, Jared S. Preston, Linda Uko, Richard S. Yoon, Frank A. Liporace

    Background High-energy radial head injuries often present with a large partial articular displaced fragment with any number of surrounding injuries. The objective of the study was to determine the characteristics of large fragment, partial articular radial head fractures and determine any significant correlation with specific injury patterns. Materials and methods Patients sustaining a radial head fracture from 2002−2010 were screened for participation. Twenty-five patients with documented partial articular radial head fractures were identified and completed the study. Our main outcome measurement was computed tomography (CT)-based analysis of the radial head fracture. The location of the radial head fracture fragment was evaluated from the axial CT scan in relation to the radial tuberosity used as a reference point. The fragment was characterized by location as anteromedial (AM), anterolateral (AL), posteromedial (PM) or posterolateral (PL) with the tuberosity referenced as straight posterior. All measurements were performed by a blinded, third party hand and upper extremity fellowship trained orthopedic surgeon. Fracture pattern, location, and size were then correlated with possible associated injuries obtained from prospective clinical data. Results The radial head fracture fragments were most commonly within the AL quadrant (16/25; 64 %). Seven fracture fragments were in the AM quadrant and two in the PM quadrant. The fragment size averaged 42.5 % of the articular surface and spanned an average angle of 134.4°. Significant differences were noted between AM (49.5 %) and AL (40.3 %) fracture fragment size with the AM fragments being larger. Seventeen cases had associated coronoid fractures. Of the total 25 cases, 13 had fracture dislocations while 12 remained reduced following the injury. The rate of dislocation was highest in radial head fractures that involved the AM quadrant (6/7; 85.7 %) compared to the AL quadrant (7/16; 43.7 %). No dislocations were observed with PM fragments. Ten of the 13 (78 %) fracture dislocations had associated lateral collateral ligament (LCL)/medial collateral ligament tear. The most common associated injuries were coronoid fractures (68 %), dislocations (52 %), and LCL tears (44 %). Conclusion The most common location for partial articular radial head fractures is the AL quadrant. The rate of elbow dislocation was highest in fractures involving the AM quadrant. Cases with large fragment, partial articular radial head fractures should undergo a CT scan; if associated with >30 % or >120° fracture arc, then the patient should be assessed closely for obvious or occult instability. These are key associations that hopefully greatly aid in the consultation and preoperative planning settings. Level of evidence Diagnostic III.


  • Exposures of the Humerus for Fracture Fixation

    by John T. Capo, Katharine T. Criner, Ben Shamian


  • Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate

    by John T. Capo, Monika P. Debkowska, Frank Liporace, Bryan G. Beutel, Eitan Melamed

    Purpose The locking compression extra-articular distal humerus plate (EADHP) is an anatomically shaped, angular stable single-column fixation system for distal third humerus fractures. The purpose of this retrospective study was to evaluate clinical and radiographic outcomes after open reduction and internal fixation of distal humerus fractures with this device. Methods Twenty-one consecutive patients with distal humerus fractures were treated with the EADHP system between February 2006 and June 2012. Of these, 19 were clinically and radiographically evaluated after a mean follow-up of 10.4 months. Follow-up assessment included anteroposterior and lateral radiographs, assessment of range of motion (ROM), pain according to a visual analogue scale (VAS) and Disabilities of the Arm, Shoulder and Hand (DASH) score. Results All fractures demonstrated satisfactory reduction and healing at an average of 7.3 months. One patient showed post-operative sensory ulnar neuropathy that recovered completely, and nine patients had a preoperative radial nerve palsy, which recovered spontaneously following exploration and plating. Mean post-operative ROM was as follows: flexion 126°, extension −7°, pronation 82° and supination 83°. The VAS score was zero points in eight patients, while the mean DASH score was 25.8 points. Conclusions For extra-articular distal humerus fractures, including high-energy injuries often seen in gunshot wounds or motor vehicle injuries, the anatomically shaped angular stable single-column plate provides satisfactory clinical and radiographic results and serves as a valuable tool in the treatment of these injuries.


  • Chronic Scaphoid Nonunion of 28-Year Duration Treated with Nonvascularized Iliac Crest Bone Graft

    by Ben Shamian, Steve Rivero, John T. Capo

    Scaphoid nonunions present a challenging clinical problem, particularly if the diagnosis of nonunion is missed or delayed. The optimal management technique can vary from free vascularized bone grafts to scaphoid excision and limited wrist fusion. The classic method of open reduction, nonvascularized corticocancellous bone grafting and internal fixation is still an effective technique. In this report, we describe a case of a 28-year-old chronic scaphoid nonunion treated with nonvascular iliac crest bone graft and internal fixation.