Frank Liporace
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Frank Liporace has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- John T. Capo
Department of Orthopaedic Surgery, New York University Hospital for Joint Diseases
2 shared publications Ben Shamian
Department of Orthopaedics, UMDNJ-New Jersey Medical School, Newark, NJ
1 shared publication- Bryan G. Beutel
Department of Primary Care, Kansas City University College of Medicine, Kansas City, Missouri, United States
1 shared publication Damon Ng
1 shared publication- Eitan Melamed
New York University Hospital for Joint Diseases, New York, NY; Woodhull Medical Center, Brooklyn, NY; Movement Analysis Laboratory, Istituto Ortopedico Rizzoli, Bologna, Italy; Joint Motion Laboratory, Department of Orthopedic Surgery, Rutgers New Jersey Medical School, Newark, NJ; Biomedical Engineering Department, School of Engineering, Rutgers University, New Brunswick, NJ
1 shared publication - John T. Capo
Department of Orthopaedics, Division of Hand and Microvascular Surgery, UMDNJ-New Jersey Medical School, Newark, NJ, USA
1 shared publication
Latest Publications
- 15 December 2013
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (5) , 1037-1043
Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate
Purpose The locking compression extra-articular distal humerus plate (EADHP) is an anatomically shaped, angular stable single-column fixation system for distal third humerus fractures. The purpose of this retrospective study was to evaluate clinical and radiographic outcomes after open reduction and internal fixation of distal humerus fractures with this device. Methods Twenty-one consecutive patients with distal humerus fractures were treated with the EADHP system between February 2006 and June 2012. Of these, 19 were clinically and radiographically evaluated after a mean follow-up of 10.4 months. Follow-up assessment included anteroposterior and lateral radiographs, assessment of range of motion (ROM), pain according to a visual analogue scale (VAS) and Disabilities of the Arm, Shoulder and Hand (DASH) score. Results All fractures demonstrated satisfactory reduction and healing at an average of 7.3 months. One patient showed post-operative sensory ulnar neuropathy that recovered completely, and nine patients had a preoperative radial nerve palsy, which recovered spontaneously following exploration and plating. Mean post-operative ROM was as follows: flexion 126°, extension −7°, pronation 82° and supination 83°. The VAS score was zero points in eight patients, while the mean DASH score was 25.8 points. Conclusions For extra-articular distal humerus fractures, including high-energy injuries often seen in gunshot wounds or motor vehicle injuries, the anatomically shaped angular stable single-column plate provides satisfactory clinical and radiographic results and serves as a valuable tool in the treatment of these injuries.
- 15 December 2013
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (5) , 1037-1043
Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate
Purpose The locking compression extra-articular distal humerus plate (EADHP) is an anatomically shaped, angular stable single-column fixation system for distal third humerus fractures. The purpose of this retrospective study was to evaluate clinical and radiographic outcomes after open reduction and internal fixation of distal humerus fractures with this device. Methods Twenty-one consecutive patients with distal humerus fractures were treated with the EADHP system between February 2006 and June 2012. Of these, 19 were clinically and radiographically evaluated after a mean follow-up of 10.4 months. Follow-up assessment included anteroposterior and lateral radiographs, assessment of range of motion (ROM), pain according to a visual analogue scale (VAS) and Disabilities of the Arm, Shoulder and Hand (DASH) score. Results All fractures demonstrated satisfactory reduction and healing at an average of 7.3 months. One patient showed post-operative sensory ulnar neuropathy that recovered completely, and nine patients had a preoperative radial nerve palsy, which recovered spontaneously following exploration and plating. Mean post-operative ROM was as follows: flexion 126°, extension −7°, pronation 82° and supination 83°. The VAS score was zero points in eight patients, while the mean DASH score was 25.8 points. Conclusions For extra-articular distal humerus fractures, including high-energy injuries often seen in gunshot wounds or motor vehicle injuries, the anatomically shaped angular stable single-column plate provides satisfactory clinical and radiographic results and serves as a valuable tool in the treatment of these injuries.
- 1 May 2013
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 24 (3) , 304-307
Hybrid compression plating for the treatment of complex distal radial fracture
Background To evaluate the radiographic and clinical outcome of hybrid compression plating for the treatment of combined fractures of the distal radius and radial shaft. Methods This is a retrospective review of 18 patients treated with open reduction and internal fixation of combined distal radial and radial shaft fractures using hybrid site-specific plating. Ten patients were men and eight were women with an average age of 46 years (range 19–90 years). The time from injury to surgery was an average of 5.8 days (range 1–16 days). Nine were open fractures and the remaining nine were closed fractures. Results Eleven of the 18 patients were available for a minimum of 3 month follow-up. The average follow-up time of these patients was 6.5 months (range 3–15 months). All fractures healed with an average healing time of 4.5 months (range 2–7 months). One patient had an infection that presented 2 months postoperatively. All fractures had acceptable alignment with good restoration of the radial bow. The average range of motion was 138° elbow flexion, 2° elbow extension, 66° wrist flexion, 54° wrist extension, 69° pronation, and 72° supination. Radiographic evaluation showed an average ulnar variance of −2.1 mm, radial bow of 14.3 mm, and location of radial bow at 55%. Conclusions This study demonstrates that hybrid compression plating can be a useful technique for the treatment of complex diaphyseal-metaphyseal fractures of the radius, resulting in good clinical and radiographic outcomes.
- 1 May 2013
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 24 (3) , 304-307
Hybrid compression plating for the treatment of complex distal radial fracture
Background To evaluate the radiographic and clinical outcome of hybrid compression plating for the treatment of combined fractures of the distal radius and radial shaft. Methods This is a retrospective review of 18 patients treated with open reduction and internal fixation of combined distal radial and radial shaft fractures using hybrid site-specific plating. Ten patients were men and eight were women with an average age of 46 years (range 19–90 years). The time from injury to surgery was an average of 5.8 days (range 1–16 days). Nine were open fractures and the remaining nine were closed fractures. Results Eleven of the 18 patients were available for a minimum of 3 month follow-up. The average follow-up time of these patients was 6.5 months (range 3–15 months). All fractures healed with an average healing time of 4.5 months (range 2–7 months). One patient had an infection that presented 2 months postoperatively. All fractures had acceptable alignment with good restoration of the radial bow. The average range of motion was 138° elbow flexion, 2° elbow extension, 66° wrist flexion, 54° wrist extension, 69° pronation, and 72° supination. Radiographic evaluation showed an average ulnar variance of −2.1 mm, radial bow of 14.3 mm, and location of radial bow at 55%. Conclusions This study demonstrates that hybrid compression plating can be a useful technique for the treatment of complex diaphyseal-metaphyseal fractures of the radius, resulting in good clinical and radiographic outcomes.
- 1 April 2009
- Vol. 38 (4) , 194-8
Bilateral comminuted radial shaft fractures from a single gunshot: fixation with alternative techniques.
Acute bilateral radial shaft fractures are an unusual entity that has not been previously reported in the literature. Given its bilaterality, this rare clinical entity is best treated with stable internal fixation. Here we report the case of an 18-year- old right-hand-dominant man who sustained a low-caliber gunshot injury. He had been driving with both hands on the steering wheel when he was struck by a single bullet. The bullet caused displaced fractures of the left proximal radial shaft and the right distal radial shaft. Each fracture had extension outside the mid-diaphysis. The patient underwent operative fixation with plating of the right upper extremity and intramedullary nailing on the left side. Both fractures healed, and range of motion was functional.
- 1 April 2009
- Vol. 38 (4) , 194-8
Bilateral comminuted radial shaft fractures from a single gunshot: fixation with alternative techniques.
Acute bilateral radial shaft fractures are an unusual entity that has not been previously reported in the literature. Given its bilaterality, this rare clinical entity is best treated with stable internal fixation. Here we report the case of an 18-year- old right-hand-dominant man who sustained a low-caliber gunshot injury. He had been driving with both hands on the steering wheel when he was struck by a single bullet. The bullet caused displaced fractures of the left proximal radial shaft and the right distal radial shaft. Each fracture had extension outside the mid-diaphysis. The patient underwent operative fixation with plating of the right upper extremity and intramedullary nailing on the left side. Both fractures healed, and range of motion was functional.