Satpal Singh Sandhu
Research Subjects
Satpal Singh Sandhu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Jasleen Sandhu
Private Practice, Jalandhar, Punjab, India
5 shared publicationsGeorge Leckie
Senior lecturer in Social Statistics, Centre for Multilevel Modelling, Graduate School of Education, University of Bristol, Bristol, United Kingdom
1 shared publicationHarpreet S. Khehra
Private Practice, Jalandhar, Punjab, India
1 shared publicationHarsimrat Kaur
Department of Orthodontics and Dentofacial Orthopedics, Genesis Institute of Dental Sciences and Research, Ferozepur and
1 shared publicationJagpreet S. Sandhu
Professor and Head, Department of Orthodontics and Dentofacial Orthopedics, Genesis Institute of Dental Sciences and Research, Ferozepur, Punjab, India
1 shared publicationJoseph Varghese
Private practice, Cochin, Kerala, India
1 shared publication
Latest Publications
- Open Access
- 1 April 2016
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 149 (4) , 491-500.e4
Orthodontic pain trajectories in adolescents: Between-subject and within-subject variability in pain perception
- 1 April 2016
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 149 (4) , 491-500.e4
Open AccessOrthodontic pain trajectories in adolescents: Between-subject and within-subject variability in pain perception
- 1 October 2015
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 148 (4) , 618-627
Effect of physical activity level on orthodontic pain perception and analgesic consumption in adolescents
- 1 October 2015
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 148 (4) , 618-627
Effect of physical activity level on orthodontic pain perception and analgesic consumption in adolescents
- Open Access
- 6 September 2014
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 37 (4) , 356-366
Reporting quality of randomized controlled trials in orthodontics—what affects it and did it improve over the last 10 years?
Introduction: Objectives were to investigate the factors affecting the overall reporting quality and the reporting quality trend of each item over the last 10 years for orthodontic randomized controlled trials (RCTs). Material and Methods: MEDLINE, The Cochrane Library, and EMBASE databases were searched (2003–12) to retrieve studies. Four major orthodontic journals and reference list of included articles were hand searched to identify additional RCTs. The overall reporting quality for all included RCTs (2003–12) was assessed using CONSORT, 2001 (ORQs 2001, score 0–20). In addition, CONSORT, 2010 (ORQs 2010, score 0–27), was used for RCTs published after 2010. Generalized estimated equations (GEEs) model was used for analysis (ORQs 2001 and ORQs 2010). Cochran–Armitage trend test was used to evaluate the reporting quality trend of each individual item based on the CONSORT, 2001. Results: Totally 309 relevant studies were identified, out of which 86 were published after 2010. The median for total ORQs 2001 and ORQs 2010 was 9 (interquartile range 7–12) and 12 (interquartile range 9–15), respectively. Year and journal of publication were significant predictors for both ORQs 2001 and ORQs 2010. Location, sample size, and multicentre trials were significant predictors only for ORQs 2001, and not for ORQs 2010. Trend test showed that reporting quality of four items, namely identification of trial as randomized, sample size, blinding, and randomization has improved significantly with time. Conclusion: There is an improvement in the reporting quality. However, it is still suboptimal. To improve the reporting quality, the CONSORT guidelines should be followed strictly.
- 6 September 2014
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 37 (4) , 356-366
Open AccessReporting quality of randomized controlled trials in orthodontics—what affects it and did it improve over the last 10 years?
Introduction: Objectives were to investigate the factors affecting the overall reporting quality and the reporting quality trend of each item over the last 10 years for orthodontic randomized controlled trials (RCTs). Material and Methods: MEDLINE, The Cochrane Library, and EMBASE databases were searched (2003–12) to retrieve studies. Four major orthodontic journals and reference list of included articles were hand searched to identify additional RCTs. The overall reporting quality for all included RCTs (2003–12) was assessed using CONSORT, 2001 (ORQs 2001, score 0–20). In addition, CONSORT, 2010 (ORQs 2010, score 0–27), was used for RCTs published after 2010. Generalized estimated equations (GEEs) model was used for analysis (ORQs 2001 and ORQs 2010). Cochran–Armitage trend test was used to evaluate the reporting quality trend of each individual item based on the CONSORT, 2001. Results: Totally 309 relevant studies were identified, out of which 86 were published after 2010. The median for total ORQs 2001 and ORQs 2010 was 9 (interquartile range 7–12) and 12 (interquartile range 9–15), respectively. Year and journal of publication were significant predictors for both ORQs 2001 and ORQs 2010. Location, sample size, and multicentre trials were significant predictors only for ORQs 2001, and not for ORQs 2010. Trend test showed that reporting quality of four items, namely identification of trial as randomized, sample size, blinding, and randomization has improved significantly with time. Conclusion: There is an improvement in the reporting quality. However, it is still suboptimal. To improve the reporting quality, the CONSORT guidelines should be followed strictly.
- Open Access
- 16 December 2013
- Published by Taylor & Francis in Journal of Orthodontics
- Vol. 40 (4) , 276-285
A randomized clinical trial investigating pain associated with superelastic nickel–titanium and multistranded stainless steel archwires during the initial leveling and aligning phase of orthodontic treatment
Objective:To investigate and compare the effects of superelastic nickel–titanium and multistranded stainless steel archwires on pain during the initial phase of orthodontic treatment.
- 16 December 2013
- Published by Taylor & Francis in Journal of Orthodontics
- Vol. 40 (4) , 276-285
Open AccessA randomized clinical trial investigating pain associated with superelastic nickel–titanium and multistranded stainless steel archwires during the initial leveling and aligning phase of orthodontic treatment
Objective:To investigate and compare the effects of superelastic nickel–titanium and multistranded stainless steel archwires on pain during the initial phase of orthodontic treatment.
- 1 November 2013
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 83 (6) , 966-972
Orthodontic pain: an interaction between age and sex in early and middle adolescence
Objective: To investigate the age and sex interaction effect on orthodontic pain in adolescence during the initial phase of fixed orthodontic treatment. Materials and Methods: Three hundred participants (mean age 13.85 ± 1.98 years; 152 female, 148 male) met all inclusion criteria and enrolled in the study designed as 2 × 2 factorial trial with two levels each for age (11–14 years; 14–17 years) and sex (male; female). A 0.16-inch superelastic NiTi wire was used in a 0.022-inch slot (Roth's prescription) preadjusted edgewise appliance for initial leveling and alignment of mandibular anterior dentition. The follow-up period was 7 days. Pain was assessed by using 100 mm visual analog scale for one baseline and nine follow-up repeated measurements at prespecified time points. Data were analyzed by using generalized linear mixed effect model analysis. Results: Three participants were lost to follow-up, and 17 participants were not considered for analysis due to incomplete or improperly completed questionnaire. Therefore, 280 participants (mean age 13.96 ± 2.01 years; 138 female, 142 male) were analyzed for results. Results showed that age and sex interaction had statistically significant effect on pain (F = 3.56; P = .0151; df 3/218). In the 11–14 year age group, there was no significant difference for pain between male and female. In the 14–17 year age group, girls reported significantly greater pain compared to 14- to 17 year-old boys (t = 2.76; P = .0209). Pain reported by 14- to 17-year-old girls was also significantly greater compared to 11- to 14-year-old boys (t = 2.91; P = .0206). Conclusions: Age and sex interaction has significant effect on orthodontic pain during adolescence, and 14- to 17-year-old girls experienced maximum pain.
- 1 November 2013
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 83 (6) , 966-972
Orthodontic pain: an interaction between age and sex in early and middle adolescence
Objective: To investigate the age and sex interaction effect on orthodontic pain in adolescence during the initial phase of fixed orthodontic treatment. Materials and Methods: Three hundred participants (mean age 13.85 ± 1.98 years; 152 female, 148 male) met all inclusion criteria and enrolled in the study designed as 2 × 2 factorial trial with two levels each for age (11–14 years; 14–17 years) and sex (male; female). A 0.16-inch superelastic NiTi wire was used in a 0.022-inch slot (Roth's prescription) preadjusted edgewise appliance for initial leveling and alignment of mandibular anterior dentition. The follow-up period was 7 days. Pain was assessed by using 100 mm visual analog scale for one baseline and nine follow-up repeated measurements at prespecified time points. Data were analyzed by using generalized linear mixed effect model analysis. Results: Three participants were lost to follow-up, and 17 participants were not considered for analysis due to incomplete or improperly completed questionnaire. Therefore, 280 participants (mean age 13.96 ± 2.01 years; 138 female, 142 male) were analyzed for results. Results showed that age and sex interaction had statistically significant effect on pain (F = 3.56; P = .0151; df 3/218). In the 11–14 year age group, there was no significant difference for pain between male and female. In the 14–17 year age group, girls reported significantly greater pain compared to 14- to 17 year-old boys (t = 2.76; P = .0209). Pain reported by 14- to 17-year-old girls was also significantly greater compared to 11- to 14-year-old boys (t = 2.91; P = .0206). Conclusions: Age and sex interaction has significant effect on orthodontic pain during adolescence, and 14- to 17-year-old girls experienced maximum pain.
- 1 September 2012
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 82 (5) , 915-921
Efficiency, behavior, and clinical properties of superelastic NiTi versus multistranded stainless steel wires
Objective: To investigate efficiency, behavior, and properties of superelastic NiTi vs multistranded stainless steel wires in Begg and preadjusted edgewise appliance (PEA) under moderate to severe crowding conditions. Material and Methods: Ninety-six participants (48 male, 48 female), aged 12–18 years old (mean age = 15.2 ± 1.95), with moderate (≤ 6 mm; mean = 5.3 ± 0.48) to severe (> 6 mm; mean = 7.9 ± 0.66) initial crowding were distributed into four groups: superelastic NiTi PEA (n = 24), superelastic NiTi Begg (n = 24), multistranded (coaxial) stainless steel PEA (n = 25), and multistranded (coaxial) stainless steel Begg (n = 23). In this study, 0.16-inch superelastic (austenitic active) NiTi and 0.175-inch multistranded (six stranded, coaxial) stainless steel wires were used in a 0.022-inch slot (Roth prescription) PEA and Begg appliance with a follow-up of six weeks. Results: Analysis of variance revealed no significant difference in reduction of crowding between superelastic NiTi PEA and multistranded (coaxial) stainless steel PEA groups, but reduction in crowding was significantly greater in the superelastic NiTi Begg group compared with the multistranded (coaxial) stainless steel Begg group with F (3, 44) = 8.896, P < .001, and effect size (ω) 0.57 in moderate crowding and F (3, 44) = 122.341, P < .001, and effect size (ω) 0.93 in severe crowding. Linear regression demonstrated significant ( P < .05) positive correlation between amount of initial crowding and reduction in crowding in all groups except the multistranded (coaxial) stainless steel Begg group, wherein a negative correlation did exist. Conclusion: Superelastic NiTi performed significantly better than multistranded (coaxial) stainless steel wire in the Begg appliance. However, in PEA, there was no significant difference.
- 1 September 2012
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 82 (5) , 915-921
Efficiency, behavior, and clinical properties of superelastic NiTi versus multistranded stainless steel wires
Objective: To investigate efficiency, behavior, and properties of superelastic NiTi vs multistranded stainless steel wires in Begg and preadjusted edgewise appliance (PEA) under moderate to severe crowding conditions. Material and Methods: Ninety-six participants (48 male, 48 female), aged 12–18 years old (mean age = 15.2 ± 1.95), with moderate (≤ 6 mm; mean = 5.3 ± 0.48) to severe (> 6 mm; mean = 7.9 ± 0.66) initial crowding were distributed into four groups: superelastic NiTi PEA (n = 24), superelastic NiTi Begg (n = 24), multistranded (coaxial) stainless steel PEA (n = 25), and multistranded (coaxial) stainless steel Begg (n = 23). In this study, 0.16-inch superelastic (austenitic active) NiTi and 0.175-inch multistranded (six stranded, coaxial) stainless steel wires were used in a 0.022-inch slot (Roth prescription) PEA and Begg appliance with a follow-up of six weeks. Results: Analysis of variance revealed no significant difference in reduction of crowding between superelastic NiTi PEA and multistranded (coaxial) stainless steel PEA groups, but reduction in crowding was significantly greater in the superelastic NiTi Begg group compared with the multistranded (coaxial) stainless steel Begg group with F (3, 44) = 8.896, P < .001, and effect size (ω) 0.57 in moderate crowding and F (3, 44) = 122.341, P < .001, and effect size (ω) 0.93 in severe crowding. Linear regression demonstrated significant ( P < .05) positive correlation between amount of initial crowding and reduction in crowding in all groups except the multistranded (coaxial) stainless steel Begg group, wherein a negative correlation did exist. Conclusion: Superelastic NiTi performed significantly better than multistranded (coaxial) stainless steel wire in the Begg appliance. However, in PEA, there was no significant difference.