Yuta Egawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yuta Egawa has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Kenichiro Takeishi
Tokushima Bunri University
3 shared publications - Yutaka Oda
Kansai University
2 shared publications Dai Shimizu
Osaka University
1 shared publication- Masaharu Komiyama
Osaka University
1 shared publication - Yutaka Oda
Department of Mechanical Engineering, Osaka University, 2-1, Yamada-oka, Suita, Osaka 5650871, Japan
1 shared publication
Latest Publications
- 27 September 2013
- Published by Wiley in Journal of Turbomachinery
- Vol. 136 (5) , 051001
Aerothermal Investigations on Mixing Flow Field of Film Cooling With Swirling Coolant Flow
This paper describes the experimental results of a new film cooling method that utilizes swirling coolant flow through circular and shaped film cooling holes. The experiments were conducted by using a scale-up model of a film-cooling hole installed on the bottom surface of a low-speed wind tunnel. Swirling motion of the film coolant was induced inside a hexagonal plenum using two diagonal impingement jets, which were inclined at an angle of α toward the vertical direction and installed in staggered positions. These two impingement jets generated a swirling flow inside the plenum, which entered the film-cooling hole and maintained its angular momentum until exiting the film-cooling hole. The slant angle of the impingement jets was changed to α = 0 deg, 10 deg, 20 deg, and 30 deg in the wind tunnel tests. The film cooling effectiveness on a flat wall was measured by a pressure sensitive paint (PSP) technique. In addition, the spatial distributions of the nondimensional concentration (or temperature) and flow field were measured by laser-induced fluorescence (LIF) and particle image velocimetry (PIV), respectively. In the case of a circular film-cooling hole, the penetration of the coolant jet into the mainstream was suppressed by the swirling motion of the coolant. As a result, although the coolant jet was deflected in the pitch direction, the film cooling effectiveness on the wall maintained a higher value behind the cooling hole over a long range. Additionally, the kidney vortex structure disappeared. For the shaped cooling hole, the coolant jet spread wider in the spanwise direction downstream. Thus, the pitch-averaged film cooling effectiveness downstream was 50% higher than that in the nonswirling case.
- 27 September 2013
- Published by Wiley in Journal of Turbomachinery
- Vol. 136 (5) , 051001
Aerothermal Investigations on Mixing Flow Field of Film Cooling With Swirling Coolant Flow
This paper describes the experimental results of a new film cooling method that utilizes swirling coolant flow through circular and shaped film cooling holes. The experiments were conducted by using a scale-up model of a film-cooling hole installed on the bottom surface of a low-speed wind tunnel. Swirling motion of the film coolant was induced inside a hexagonal plenum using two diagonal impingement jets, which were inclined at an angle of α toward the vertical direction and installed in staggered positions. These two impingement jets generated a swirling flow inside the plenum, which entered the film-cooling hole and maintained its angular momentum until exiting the film-cooling hole. The slant angle of the impingement jets was changed to α = 0 deg, 10 deg, 20 deg, and 30 deg in the wind tunnel tests. The film cooling effectiveness on a flat wall was measured by a pressure sensitive paint (PSP) technique. In addition, the spatial distributions of the nondimensional concentration (or temperature) and flow field were measured by laser-induced fluorescence (LIF) and particle image velocimetry (PIV), respectively. In the case of a circular film-cooling hole, the penetration of the coolant jet into the mainstream was suppressed by the swirling motion of the coolant. As a result, although the coolant jet was deflected in the pitch direction, the film cooling effectiveness on the wall maintained a higher value behind the cooling hole over a long range. Additionally, the kidney vortex structure disappeared. For the shaped cooling hole, the coolant jet spread wider in the spanwise direction downstream. Thus, the pitch-averaged film cooling effectiveness downstream was 50% higher than that in the nonswirling case.
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2011, 29-30
B114 Film Cooling with Swirling Coolant Flow Induced by Internal Impingement Jet Cooling
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2011, 29-30
B114 Film Cooling with Swirling Coolant Flow Induced by Internal Impingement Jet Cooling
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2011.16, 479-480
G227 Numerical study of shaped film cooling with swirling coolant air
This paper describes numerical results of a shaped film cooling with swirling coolant air. In recent experimental studies, it has shown that the film-cooling effectiveness on the wall can be improved by adding a swirl to coolant air without the growth of coolant flow rate in both cases of the circular and typical shaped holes. In the latest paper, it has been revealed that one of the RANS model is useful to predict better swirling conditions and stronger swirl leads better film-cooling effectiveness on the wall in the case of circular hole. In this paper, the case of shaped hole with swirling coolant air is studied numerically. Numerical simulations are performed by employing RANS models with parameter of swirl intensity. The numerical results are also compared with experimental results already shown.
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2011.16, 479-480
G227 Numerical study of shaped film cooling with swirling coolant air
This paper describes numerical results of a shaped film cooling with swirling coolant air. In recent experimental studies, it has shown that the film-cooling effectiveness on the wall can be improved by adding a swirl to coolant air without the growth of coolant flow rate in both cases of the circular and typical shaped holes. In the latest paper, it has been revealed that one of the RANS model is useful to predict better swirling conditions and stronger swirl leads better film-cooling effectiveness on the wall in the case of circular hole. In this paper, the case of shaped hole with swirling coolant air is studied numerically. Numerical simulations are performed by employing RANS models with parameter of swirl intensity. The numerical results are also compared with experimental results already shown.