Yutaka Oda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yutaka Oda has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Kenichiro Takeishi
Tokushima Bunri University
2 shared publications - Masaharu Komiyama
Osaka University
1 shared publication - Yoshiaki Miyake
Guidance & Propulsion Division, Aerospace Systems, Mitsubishi Heavy Industries Ltd., 1200 Higashitanaka, Komaki, Aichi 485-8561, Japan
1 shared publication - Yusuke Motoda
Washlet Development Department No.1, Toto Ltd., 1-1-1 Maigaoka, Kokuraminami-ku, Kitakyushu, Fukuoka 803-0823, Japan
1 shared publication - Yuta Egawa
Die Casting Engineering Department, Toyota Motor Co. 1, Toyota-cho, Toyota City 4718571, Japan
1 shared publication
Latest Publications
- 27 September 2013
- Published by Wiley in Journal of Turbomachinery
- Vol. 136 (5) , 051001
Aerothermal Investigations on Mixing Flow Field of Film Cooling With Swirling Coolant Flow
This paper describes the experimental results of a new film cooling method that utilizes swirling coolant flow through circular and shaped film cooling holes. The experiments were conducted by using a scale-up model of a film-cooling hole installed on the bottom surface of a low-speed wind tunnel. Swirling motion of the film coolant was induced inside a hexagonal plenum using two diagonal impingement jets, which were inclined at an angle of α toward the vertical direction and installed in staggered positions. These two impingement jets generated a swirling flow inside the plenum, which entered the film-cooling hole and maintained its angular momentum until exiting the film-cooling hole. The slant angle of the impingement jets was changed to α = 0 deg, 10 deg, 20 deg, and 30 deg in the wind tunnel tests. The film cooling effectiveness on a flat wall was measured by a pressure sensitive paint (PSP) technique. In addition, the spatial distributions of the nondimensional concentration (or temperature) and flow field were measured by laser-induced fluorescence (LIF) and particle image velocimetry (PIV), respectively. In the case of a circular film-cooling hole, the penetration of the coolant jet into the mainstream was suppressed by the swirling motion of the coolant. As a result, although the coolant jet was deflected in the pitch direction, the film cooling effectiveness on the wall maintained a higher value behind the cooling hole over a long range. Additionally, the kidney vortex structure disappeared. For the shaped cooling hole, the coolant jet spread wider in the spanwise direction downstream. Thus, the pitch-averaged film cooling effectiveness downstream was 50% higher than that in the nonswirling case.
- 27 September 2013
- Published by Wiley in Journal of Turbomachinery
- Vol. 136 (5) , 051001
Aerothermal Investigations on Mixing Flow Field of Film Cooling With Swirling Coolant Flow
This paper describes the experimental results of a new film cooling method that utilizes swirling coolant flow through circular and shaped film cooling holes. The experiments were conducted by using a scale-up model of a film-cooling hole installed on the bottom surface of a low-speed wind tunnel. Swirling motion of the film coolant was induced inside a hexagonal plenum using two diagonal impingement jets, which were inclined at an angle of α toward the vertical direction and installed in staggered positions. These two impingement jets generated a swirling flow inside the plenum, which entered the film-cooling hole and maintained its angular momentum until exiting the film-cooling hole. The slant angle of the impingement jets was changed to α = 0 deg, 10 deg, 20 deg, and 30 deg in the wind tunnel tests. The film cooling effectiveness on a flat wall was measured by a pressure sensitive paint (PSP) technique. In addition, the spatial distributions of the nondimensional concentration (or temperature) and flow field were measured by laser-induced fluorescence (LIF) and particle image velocimetry (PIV), respectively. In the case of a circular film-cooling hole, the penetration of the coolant jet into the mainstream was suppressed by the swirling motion of the coolant. As a result, although the coolant jet was deflected in the pitch direction, the film cooling effectiveness on the wall maintained a higher value behind the cooling hole over a long range. Additionally, the kidney vortex structure disappeared. For the shaped cooling hole, the coolant jet spread wider in the spanwise direction downstream. Thus, the pitch-averaged film cooling effectiveness downstream was 50% higher than that in the nonswirling case.
- 20 May 2013
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 135 (6) , 061902
Convective Heat Transfer and Pressure Loss in Rectangular Ducts With Inclined Pin-Fin on a Wavy Endwall
Local endwall heat transfer characteristics and overall pressure loss of normal and inclined pin fins arrayed in rectangular ducts with flat and wavy endwalls have been investigated to improve the cooling efficiency of jet engine combustor liners. The detailed time-mean local Nusselt number profiles were measured using a naphthalene sublimation method based on the heat/mass transfer analogy. Four kinds of angled pin fins (−45, 0, and +45 deg with a flat endwall, and −45 deg with a wavy endwall) were tested and compared with each other. As a result, the average heat transfer coefficient on the flat endwall of normal pin fins was higher than that of the angled pin fins. The average heat transfer coefficient of −45-deg inclined pin fins with a wavy endwall is the same or a little higher than the heat transfer coefficient of those with a flat endwall; however, the pressure loss of the −45-deg inclined pin fins with a wavy endwall is less than the pressure loss of those with a flat endwall. Corresponding numerical simulations using large eddy simulation (LES) with the mixed time scale (MTS) model have been also conducted at Red = 1000 for fully developed regions, and the results have shown good quantitative agreement with mass transfer experiments. It can be concluded that wavy endwalls can realize better heat transfer with less pressure loss as long as the aim consists in enhancing endwall heat transfer in inclined pin-fin channels.
- 20 May 2013
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 135 (6) , 061902
Convective Heat Transfer and Pressure Loss in Rectangular Ducts With Inclined Pin-Fin on a Wavy Endwall
Local endwall heat transfer characteristics and overall pressure loss of normal and inclined pin fins arrayed in rectangular ducts with flat and wavy endwalls have been investigated to improve the cooling efficiency of jet engine combustor liners. The detailed time-mean local Nusselt number profiles were measured using a naphthalene sublimation method based on the heat/mass transfer analogy. Four kinds of angled pin fins (−45, 0, and +45 deg with a flat endwall, and −45 deg with a wavy endwall) were tested and compared with each other. As a result, the average heat transfer coefficient on the flat endwall of normal pin fins was higher than that of the angled pin fins. The average heat transfer coefficient of −45-deg inclined pin fins with a wavy endwall is the same or a little higher than the heat transfer coefficient of those with a flat endwall; however, the pressure loss of the −45-deg inclined pin fins with a wavy endwall is less than the pressure loss of those with a flat endwall. Corresponding numerical simulations using large eddy simulation (LES) with the mixed time scale (MTS) model have been also conducted at Red = 1000 for fully developed regions, and the results have shown good quantitative agreement with mass transfer experiments. It can be concluded that wavy endwalls can realize better heat transfer with less pressure loss as long as the aim consists in enhancing endwall heat transfer in inclined pin-fin channels.