KHKeith A. Horvath

Keith A. Horvath

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Keith A. Horvath has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Abbas Emaminia

    Cardiothoracic Surgery Research Program, National Institutes of Health Heart Center at Suburban Hospital, Bethesda, MD, USA

    1 shared publication
  • Cristian Militaru

    National Heart, Lung, and Blood Institute, National Institutes of Health

    1 shared publication
  • Damien J. LaPar

    Department of Surgery, University of Virginia, Charlottesville, VA

    1 shared publication
  • Dumitru Mazilu

    Cardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Building 10, Room B1D47, MSC 1550, 10 Center Drive, Bethesda, MD, 20892, USA

    1 shared publication
  • Dumitru Mazilu

    Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA

    1 shared publication
  • Joshua L. Chan

    Division of Cardiothoracic Surgery, Department of Surgery, Emory University School of Medicine, Atlanta, GA, USA

    1 shared publication

Latest Publications

  • Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model

    by Joshua L. Chan, Dumitru Mazilu, Justin G. Miller, Timothy Hunt, Keith A. Horvath, Ming Li

    Purpose Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constrained procedural environment. To address these concerns, a magnetic resonance (MR)-compatible robotic system to assist in TAVR deployments was developed. This study evaluates the technical design and interface considerations of an MR-compatible robotic-assisted TAVR system with the purpose of demonstrating that such a system can be developed and executed safely and precisely in a preclinical model. Methods An MR-compatible robotic surgical assistant system was built for TAVR deployment. This system integrates a 5-degrees of freedom (DoF) robotic arm with a 3-DoF robotic valve delivery module. A user interface system was designed for procedural planning and real-time intraoperative manipulation of the robot. The robotic device was constructed of plastic materials, pneumatic actuators, and fiber-optical encoders. Results The mechanical profile and MR compatibility of the robotic system were evaluated. The system-level error based on a phantom model was 1.14 ± 0.33 mm. A self-expanding prosthesis was successfully deployed in eight Yorkshire swine under rtMRI guidance. Post-deployment imaging and necropsy confirmed placement of the stent within 3 mm of the aortic valve annulus. Conclusions These phantom and in vivo studies demonstrate the feasibility and advantages of robotic-assisted TAVR under rtMRI guidance. This robotic system increases the precision of valve deployments, diminishes environmental constraints, and improves the overall success of TAVR.


  • Self-Expanding Stent and Delivery System for Aortic Valve Replacement

    by Dumitru Mazilu, Ming Li, Ozgur Kocaturk, Keith A. Horvath

    Currently, aortic valve replacement procedures require a sternotomy and use of cardiopulmonary bypass (CPB) to arrest the heart and provide a bloodless field in which to operate. A less invasive alternative to open heart surgery is transapical or transcatheter aortic valve replacement (TAVR), already emerging as a feasible treatment for patients with high surgical risk. The bioprosthetic valves are delivered via catheters using transarterial or transapical approaches and are implanted within diseased aortic valves. This paper reports the development of a new self-expanding stent for minimally invasive aortic valve replacement and its delivery device for the transapical approach under real-time magnetic resonance imaging (MRI) guidance. Made of nitinol, the new stent is designed to implant and embed a commercially available bioprosthetic aortic valve in aortic root. An MRI passive marker was affixed onto the stent and an MRI active marker to the delivery device. These capabilities were tested in ex vivo and in vivo experiments. Radial resistive force, chronic outward force, and the integrity of bioprosthesis on stent were measured through custom design dedicated test equipment. In vivo experimental evaluation was done using a porcine large animal model. Both ex vivo and in vivo experiment results indicate that the self-expanding stent provides adequate reinforcement of the bioprosthetic aortic valve and it is easier to implant the valve in the correct position. The orientation and positioning of the implanted valve is more precise and predictable with the help of the passive marker on stent and the active marker on delivery device. The new self-expanding nitinol stent was designed to exert a constant radial force and, therefore, a better fixation of the prosthesis in the aorta, which would result in better preservation of long-term heart function. The passive marker affixed on the stent and active marker embedded in the delivery devices helps to achieve precise orientation and positioning of the stent under MRI guidance. The design allows the stent to be retracted in the delivery device with a snaring catheter if necessary. Histopathology reports reveal that the stent is biocompatible and fully functional. All the stented bioprosthesis appeared to be properly seated in the aortic root.


  • The universal bed model for patient care improves outcome and lowers cost in cardiac surgery

    by Abbas Emaminia, Phillip C. Corcoran, Michael P. Siegenthaler, Melissa Means, Sarah Rasmussen, Linda Krause, Damien J. LaPar, Keith A. Horvath