Dumitru Mazilu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dumitru Mazilu has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Eric E. Bennett
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
4 shared publications - Han Wen
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
4 shared publications - Dan Stoianovici
Johns Hopkins University
2 shared publications - Farah Hussaini
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications - Muyang Wang
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications - Shefra Shah
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications
Latest Publications
- Open Access
- 13 June 2025
- Published by MDPI AG in Methods and Protocols
- Vol. 8 (3)
Cystic Lung Phantom to Validate Clinical CT Protocols
In computed tomography (CT)-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. We describe an easy-to-replicate cystic lung phantom consisting of basic lung structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner, various structures in the lung phantom were correctly recognized by two types of lung analysis software. The resulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. The significant finding was that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and deserves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
- 13 June 2025
- Published by MDPI AG in Methods and Protocols
- Vol. 8 (3)
Open AccessCystic Lung Phantom to Validate Clinical CT Protocols
In computed tomography (CT)-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. We describe an easy-to-replicate cystic lung phantom consisting of basic lung structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner, various structures in the lung phantom were correctly recognized by two types of lung analysis software. The resulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. The significant finding was that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and deserves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
- Open Access
Cystic Lung Phantom to Validate Clinical CT Protocols
In CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
Open AccessCystic Lung Phantom to Validate Clinical CT Protocols
In CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
- Open Access
- 21 October 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (10) , 292
Online Calibration of a Linear Micro Tomosynthesis Scanner
In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeters size at 10 µm resolution, the mechanical instability of the scanning stage (±10 µm) exceeded the resolution of the image system, making it necessary to determine the trajectory of the stage for each scan to avoid blurring and artifacts in the images that would arise from the errors in the geometric information used in 3D reconstruction. We present a method for online calibration by attaching a layer of randomly dispersed micro glass beads or calcium particles to the bottom of the sample stage. The method was based on a parametric representation of the rigid body motion of the sample stage-marker layer assembly. The marker layer was easy to produce and proven effective in the calibration procedure.
- 21 October 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (10) , 292
Open AccessOnline Calibration of a Linear Micro Tomosynthesis Scanner
In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeters size at 10 µm resolution, the mechanical instability of the scanning stage (±10 µm) exceeded the resolution of the image system, making it necessary to determine the trajectory of the stage for each scan to avoid blurring and artifacts in the images that would arise from the errors in the geometric information used in 3D reconstruction. We present a method for online calibration by attaching a layer of randomly dispersed micro glass beads or calcium particles to the bottom of the sample stage. The method was based on a parametric representation of the rigid body motion of the sample stage-marker layer assembly. The marker layer was easy to produce and proven effective in the calibration procedure.
- Open Access
- 12 October 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2547-2555
Online Geometric Calibration of a Hybrid CT System for Ultrahigh-Resolution Imaging
A hybrid imaging system consisting of a standard computed tomography (CT) scanner and a low-profile photon-counting detector insert in contact with the patient’s body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of patients. The detector insert is placed on the patient bed as needed and not attached. Thus, its position and orientation in the scanner is dependent on the patient’s position and scan settings. To allow accurate image reconstruction, we devised a method of determining the relative geometry of the detector insert and the CT scanner for each scan using fiducial markers. This method uses an iterative registration algorithm to align the markers in the reconstructed volume from the detector insert to that of the concurrent CT scan. After obtaining precise geometric information of the detector insert relative to the CT scanner, the two complementary sets of images are summed together to create a detailed image with reduced artifacts.
- 12 October 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2547-2555
Open AccessOnline Geometric Calibration of a Hybrid CT System for Ultrahigh-Resolution Imaging
A hybrid imaging system consisting of a standard computed tomography (CT) scanner and a low-profile photon-counting detector insert in contact with the patient’s body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of patients. The detector insert is placed on the patient bed as needed and not attached. Thus, its position and orientation in the scanner is dependent on the patient’s position and scan settings. To allow accurate image reconstruction, we devised a method of determining the relative geometry of the detector insert and the CT scanner for each scan using fiducial markers. This method uses an iterative registration algorithm to align the markers in the reconstructed volume from the detector insert to that of the concurrent CT scan. After obtaining precise geometric information of the detector insert relative to the CT scanner, the two complementary sets of images are summed together to create a detailed image with reduced artifacts.
- 1 March 2015
- Vol. 24 (2) , 139-47
Pathology of balloon-expandable and self-expanding stents following MRI-guided transapical aortic valve replacement.
Balloon-expandable (BE) and self-expanding (SE) prostheses are both used for transcatheter aortic valve replacement (TAVR), but differences in long-term outcome using these types of device are unknown. The study aim was to monitor the histopathology, echocardiographic findings and structural integrity of BE and SE stents in a preclinical model for up to six months after TAVR. Real-time magnetic resonance imaging (rtMRI)-guided TAVR was performed in 22 Yucatan pigs using either a BE (n = 10) or a SE (n = 12) prosthesis. Follow up echocardiography and MRI studies were performed at one-, three-, and six-month intervals. Additionally, high-contrast radiography was used to assess for strut fractures. The pigs were sacrificed after six months and tissues taken for histopathologic analysis. Stent malapposition was found in seven BE prostheses (70%), and in three SE prostheses (25%) (p = 0.046). Three of the SE group (25%) had a partial left coronary artery obstruction. The incidence and severity of aortic regurgitation were similar between the BE and SE groups. Three BE prostheses (30%) and one SE prosthesis (8.3%) had a gap between the stent frame and aorta. The mean (±SD) number of strut fractures was 6.1 ± 3.45 and 1.17 ± 2.32 in the BE and SE groups, respectively (p = 0.002). In addition, two implanted BE prostheses (20%) had a consequential compressed stent frame appearance. Long-term pathologic examination of necropsy specimens from a preclinical model of rtMRI-guided TAVR showed SE stent prostheses to be superior to their BE counterparts in terms of correct valve apposition and durability. These results may be attributed to the differing deployment methods and associated expansion forces employed by the BE and SE stents.
- 1 March 2015
- Vol. 24 (2) , 139-47
Pathology of balloon-expandable and self-expanding stents following MRI-guided transapical aortic valve replacement.
Balloon-expandable (BE) and self-expanding (SE) prostheses are both used for transcatheter aortic valve replacement (TAVR), but differences in long-term outcome using these types of device are unknown. The study aim was to monitor the histopathology, echocardiographic findings and structural integrity of BE and SE stents in a preclinical model for up to six months after TAVR. Real-time magnetic resonance imaging (rtMRI)-guided TAVR was performed in 22 Yucatan pigs using either a BE (n = 10) or a SE (n = 12) prosthesis. Follow up echocardiography and MRI studies were performed at one-, three-, and six-month intervals. Additionally, high-contrast radiography was used to assess for strut fractures. The pigs were sacrificed after six months and tissues taken for histopathologic analysis. Stent malapposition was found in seven BE prostheses (70%), and in three SE prostheses (25%) (p = 0.046). Three of the SE group (25%) had a partial left coronary artery obstruction. The incidence and severity of aortic regurgitation were similar between the BE and SE groups. Three BE prostheses (30%) and one SE prosthesis (8.3%) had a gap between the stent frame and aorta. The mean (±SD) number of strut fractures was 6.1 ± 3.45 and 1.17 ± 2.32 in the BE and SE groups, respectively (p = 0.002). In addition, two implanted BE prostheses (20%) had a consequential compressed stent frame appearance. Long-term pathologic examination of necropsy specimens from a preclinical model of rtMRI-guided TAVR showed SE stent prostheses to be superior to their BE counterparts in terms of correct valve apposition and durability. These results may be attributed to the differing deployment methods and associated expansion forces employed by the BE and SE stents.
- 1 November 2012
- Published by ASME International in Journal of Medical Devices
- Vol. 6 (4) , 041006-0410069
Self-Expanding Stent and Delivery System for Aortic Valve Replacement
Currently, aortic valve replacement procedures require a sternotomy and use of cardiopulmonary bypass (CPB) to arrest the heart and provide a bloodless field in which to operate. A less invasive alternative to open heart surgery is transapical or transcatheter aortic valve replacement (TAVR), already emerging as a feasible treatment for patients with high surgical risk. The bioprosthetic valves are delivered via catheters using transarterial or transapical approaches and are implanted within diseased aortic valves. This paper reports the development of a new self-expanding stent for minimally invasive aortic valve replacement and its delivery device for the transapical approach under real-time magnetic resonance imaging (MRI) guidance. Made of nitinol, the new stent is designed to implant and embed a commercially available bioprosthetic aortic valve in aortic root. An MRI passive marker was affixed onto the stent and an MRI active marker to the delivery device. These capabilities were tested in ex vivo and in vivo experiments. Radial resistive force, chronic outward force, and the integrity of bioprosthesis on stent were measured through custom design dedicated test equipment. In vivo experimental evaluation was done using a porcine large animal model. Both ex vivo and in vivo experiment results indicate that the self-expanding stent provides adequate reinforcement of the bioprosthetic aortic valve and it is easier to implant the valve in the correct position. The orientation and positioning of the implanted valve is more precise and predictable with the help of the passive marker on stent and the active marker on delivery device. The new self-expanding nitinol stent was designed to exert a constant radial force and, therefore, a better fixation of the prosthesis in the aorta, which would result in better preservation of long-term heart function. The passive marker affixed on the stent and active marker embedded in the delivery devices helps to achieve precise orientation and positioning of the stent under MRI guidance. The design allows the stent to be retracted in the delivery device with a snaring catheter if necessary. Histopathology reports reveal that the stent is biocompatible and fully functional. All the stented bioprosthesis appeared to be properly seated in the aortic root.
- 1 November 2012
- Published by ASME International in Journal of Medical Devices
- Vol. 6 (4) , 041006-0410069
Self-Expanding Stent and Delivery System for Aortic Valve Replacement
Currently, aortic valve replacement procedures require a sternotomy and use of cardiopulmonary bypass (CPB) to arrest the heart and provide a bloodless field in which to operate. A less invasive alternative to open heart surgery is transapical or transcatheter aortic valve replacement (TAVR), already emerging as a feasible treatment for patients with high surgical risk. The bioprosthetic valves are delivered via catheters using transarterial or transapical approaches and are implanted within diseased aortic valves. This paper reports the development of a new self-expanding stent for minimally invasive aortic valve replacement and its delivery device for the transapical approach under real-time magnetic resonance imaging (MRI) guidance. Made of nitinol, the new stent is designed to implant and embed a commercially available bioprosthetic aortic valve in aortic root. An MRI passive marker was affixed onto the stent and an MRI active marker to the delivery device. These capabilities were tested in ex vivo and in vivo experiments. Radial resistive force, chronic outward force, and the integrity of bioprosthesis on stent were measured through custom design dedicated test equipment. In vivo experimental evaluation was done using a porcine large animal model. Both ex vivo and in vivo experiment results indicate that the self-expanding stent provides adequate reinforcement of the bioprosthetic aortic valve and it is easier to implant the valve in the correct position. The orientation and positioning of the implanted valve is more precise and predictable with the help of the passive marker on stent and the active marker on delivery device. The new self-expanding nitinol stent was designed to exert a constant radial force and, therefore, a better fixation of the prosthesis in the aorta, which would result in better preservation of long-term heart function. The passive marker affixed on the stent and active marker embedded in the delivery devices helps to achieve precise orientation and positioning of the stent under MRI guidance. The design allows the stent to be retracted in the delivery device with a snaring catheter if necessary. Histopathology reports reveal that the stent is biocompatible and fully functional. All the stented bioprosthesis appeared to be properly seated in the aortic root.
- 12 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 12 (1) , 98-106
A New Type of Motor: Pneumatic Step Motor
This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications
- 12 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 12 (1) , 98-106
A New Type of Motor: Pneumatic Step Motor
This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications
- 1 January 2005
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 01 (02) , 40
Precision placement of instruments for minimally invasive procedures using a "Needle Driver" robot
- 1 January 2005
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 01 (02) , 40
Precision placement of instruments for minimally invasive procedures using a "Needle Driver" robot