S. S. Murthy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
S. S. Murthy has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Bhim Singh
Indian Institute of Technology Delhi
5 shared publications Bhim Singh
Department of Electrical Engineering Indian Institute of Technology Delhi New Delhi 110016 India
4 shared publicationsA. K. Tandon
Department of Electrical Engineering, Delhi College of Engineering, Delhi-110016, India
2 shared publicationsB. P. Singh
Department of Electric Engineering , Indian Institute of Technology , New Delhi, India
2 shared publications- Gurumoorthy Bhuvaneswari
Department of Electrical Engineering, Indian Institute of Technology, New Delhi, India
2 shared publications - M. Sree Lalitha Gayathri
HCL Technologies Limited, Bangalore, INDIA
2 shared publications
Latest Publications
- 11 October 2013
- Published by Elsevier in Electric Power Systems Research
- Vol. 107, 36-44
An analytical performance comparison of two winding and three winding single phase SEIGs
- 11 October 2013
- Published by Elsevier in Electric Power Systems Research
- Vol. 107, 36-44
An analytical performance comparison of two winding and three winding single phase SEIGs
- Open Access
- 1 July 2013
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 7 (6) , 477-486
Design‐based computational procedure for performance prediction and analysis of single‐phase self‐excited induction generator
The study presents a design‐based computational procedure for determining the performance of a single‐phase two‐winding self‐excited induction generator (SEIG) taking the machine design details as the input data. The magnetisation characteristic that forms the basis of analysis is obtained using the B – H curve of the core material and by employing an appropriate curve‐fitting/regression technique that leads to obtain V g – I m variation from which V g – X m variation can be derived. The predicted parameters and performance characteristics of a single‐phase SEIG are compared with the corresponding experimental results. This procedure can be a powerful tool for improved design of such machines. Effects of variation of typical design parameters on performance are presented to demonstrate its utility.
- 1 July 2013
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 7 (6) , 477-486
Open AccessDesign‐based computational procedure for performance prediction and analysis of single‐phase self‐excited induction generator
The study presents a design‐based computational procedure for determining the performance of a single‐phase two‐winding self‐excited induction generator (SEIG) taking the machine design details as the input data. The magnetisation characteristic that forms the basis of analysis is obtained using the B – H curve of the core material and by employing an appropriate curve‐fitting/regression technique that leads to obtain V g – I m variation from which V g – X m variation can be derived. The predicted parameters and performance characteristics of a single‐phase SEIG are compared with the corresponding experimental results. This procedure can be a powerful tool for improved design of such machines. Effects of variation of typical design parameters on performance are presented to demonstrate its utility.
- 17 November 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 46 (1) , 94-101
A Stand-Alone Generating System Using Self-Excited Induction Generators in the Extraction of Petroleum Products
This paper demonstrates a simple electricity generating system that can supply electricity in remote areas such as seashores, hilly regions, etc. Many coastal areas have layers of rock under the sea with considerable petroleum reserves. To extract the petroleum products, electricity is required. In such situations, stand-alone power generating system is preferred. The proposed electricity generating system consists of self-excited induction generator (SEIG) and static compensator (STATCOM)-based voltage regulator. The STATCOM supplies variable reactive power to the SEIG and acts as a voltage regulator. Apart from voltage regulation of SEIG, the STATCOM balances the generating system under unbalanced loading conditions and filters the harmonics of the loads, thereby acting both as balancer and harmonic eliminator. It also enhances the loadability, even to start and run dynamic loads such as induction motors.
- 17 November 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 46 (1) , 94-101
A Stand-Alone Generating System Using Self-Excited Induction Generators in the Extraction of Petroleum Products
This paper demonstrates a simple electricity generating system that can supply electricity in remote areas such as seashores, hilly regions, etc. Many coastal areas have layers of rock under the sea with considerable petroleum reserves. To extract the petroleum products, electricity is required. In such situations, stand-alone power generating system is preferred. The proposed electricity generating system consists of self-excited induction generator (SEIG) and static compensator (STATCOM)-based voltage regulator. The STATCOM supplies variable reactive power to the SEIG and acts as a voltage regulator. Apart from voltage regulation of SEIG, the STATCOM balances the generating system under unbalanced loading conditions and filters the harmonics of the loads, thereby acting both as balancer and harmonic eliminator. It also enhances the loadability, even to start and run dynamic loads such as induction motors.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance Analysis of a Self Excited Induction Generator with Digitally Controlled Electronic Load Controller for Micro Hydel Power Generation
This paper presents the analysis of dynamic and steady state performance of a self excited induction generator (SEIG) with digitally controlled electronic load controller (ELC) feeding single phase loads. The excitation capacitors, electronic load controller, 1-phase load in conjunction with the d-q model of the 3-phase induction machine taking into account the saturation effect are used to predict the dynamic behavior of the SEIG. The digital control is realized by means of PIC18F252 microcontroller which provides a better performance with increased operational flexibility. Both simulation and hardware results have been presented for the digitally controlled ELC, which is more compact, reliable and cost effective for providing effective voltage regulation for field applications.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance Analysis of a Self Excited Induction Generator with Digitally Controlled Electronic Load Controller for Micro Hydel Power Generation
This paper presents the analysis of dynamic and steady state performance of a self excited induction generator (SEIG) with digitally controlled electronic load controller (ELC) feeding single phase loads. The excitation capacitors, electronic load controller, 1-phase load in conjunction with the d-q model of the 3-phase induction machine taking into account the saturation effect are used to predict the dynamic behavior of the SEIG. The digital control is realized by means of PIC18F252 microcontroller which provides a better performance with increased operational flexibility. Both simulation and hardware results have been presented for the digitally controlled ELC, which is more compact, reliable and cost effective for providing effective voltage regulation for field applications.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Novel Digital Control Technique of Electronic Load Controller for SEIG Based Micro Hydel Power Generation
This paper presents the dynamic and steady state performance of a stand alone self excited induction generator (SEIG) with digitally controlled electronic load controller feeding single phase and three phase loads. The values of the capacitances are chosen to ensure self-excitation of the machine and to minimize the unbalance between the stator voltages. The excitation capacitors, ELC and load combined with the d-q model of the machine, together with the saturation are used to predict the dynamic behavior of the SEIG. This paper mainly deals with the viability of using digitally controlled ELC, which is more compact, reliable and cost effective for providing effective voltage regulation.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Novel Digital Control Technique of Electronic Load Controller for SEIG Based Micro Hydel Power Generation
This paper presents the dynamic and steady state performance of a stand alone self excited induction generator (SEIG) with digitally controlled electronic load controller feeding single phase and three phase loads. The values of the capacitances are chosen to ensure self-excitation of the machine and to minimize the unbalance between the stator voltages. The excitation capacitors, ELC and load combined with the d-q model of the machine, together with the saturation are used to predict the dynamic behavior of the SEIG. This paper mainly deals with the viability of using digitally controlled ELC, which is more compact, reliable and cost effective for providing effective voltage regulation.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Novel Integral Cycle Voltage Controller for Self Excited Induction Generators
This paper presents the theory of a new VAr regulator used for voltage control of self excited induction generators (SEIG). In this approach the excitation capacitors of each phase are switched individually by IGBTs at the zero crossing of respective capacitor currents, thereby eliminating switching losses and harmonics and reducing component count. Simulation results using Matlab-Simulink are presented and compared with experimentally obtained results. The developed integral control scheme presented here overcomes all the shortcomings of existing control schemes and, in addition to being self-starting is also capable of handling capacitive loads, thus making its application in standby generators acceptable with associated reduction in unit costs.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Novel Integral Cycle Voltage Controller for Self Excited Induction Generators
This paper presents the theory of a new VAr regulator used for voltage control of self excited induction generators (SEIG). In this approach the excitation capacitors of each phase are switched individually by IGBTs at the zero crossing of respective capacitor currents, thereby eliminating switching losses and harmonics and reducing component count. Simulation results using Matlab-Simulink are presented and compared with experimentally obtained results. The developed integral control scheme presented here overcomes all the shortcomings of existing control schemes and, in addition to being self-starting is also capable of handling capacitive loads, thus making its application in standby generators acceptable with associated reduction in unit costs.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Steady State Analysis on Voltage and Frequency Control of Self-Excited Induction Generator in Micro-Hydro System
This paper presents a steady state analysis of self-excited induction generator (SEIG) operating with an electronic load controller (ELC) for regulating its voltage and frequency under varying load condition. The ELC consists of a rectifier and a chopper circuit whose operation generates harmonics on AC side of the SEIG system. To achieve an adequate performance characteristics of the SEIG with ELC information of harmonic contents and real power is necessary. In this paper a complete description of the AC current harmonics generated in the ELC operation and their effects on the performance of SEIG is presented in detail.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Steady State Analysis on Voltage and Frequency Control of Self-Excited Induction Generator in Micro-Hydro System
This paper presents a steady state analysis of self-excited induction generator (SEIG) operating with an electronic load controller (ELC) for regulating its voltage and frequency under varying load condition. The ELC consists of a rectifier and a chopper circuit whose operation generates harmonics on AC side of the SEIG system. To achieve an adequate performance characteristics of the SEIG with ELC information of harmonic contents and real power is necessary. In this paper a complete description of the AC current harmonics generated in the ELC operation and their effects on the performance of SEIG is presented in detail.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Design of Squirrel Cage Induction Motors for Traction Applications
This paper highlights the design issues of high power induction motors for traction applications. The circuit modeling and analysis of an induction machine is carried out with the parameters calculated from physical dimensions. The modification of the parameters to incorporate the time harmonic effects of inverter PWM supply, flux and frequency variation effect during closed loop V/F control is investigated in detail. The design program of the machine is developed using MATLAB.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Design of Squirrel Cage Induction Motors for Traction Applications
This paper highlights the design issues of high power induction motors for traction applications. The circuit modeling and analysis of an induction machine is carried out with the parameters calculated from physical dimensions. The modification of the parameters to incorporate the time harmonic effects of inverter PWM supply, flux and frequency variation effect during closed loop V/F control is investigated in detail. The design program of the machine is developed using MATLAB.
- 1 February 2006
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 34 (2) , 141-157
A Voltage and Frequency Controller for Self-Excited Induction Generators
This article describes a controller for voltage and frequency control of self-excited induction generator (SEIG) supplying static/dynamic, balanced/unbalanced loads. The controller is a combination of a three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC-VSI) and a high frequency DC chopper, which keeps the generated voltage and frequency constant in spite of change in consumer loads. A mathematical model of the SEIG with this controller supplying different types of loads is developed for predicting the behavior of the system under transient and dynamic conditions. The simulated results show that generated frequency and voltage remain constant with change in load. The proposed controller acts as reactive power compensator, harmonic eliminator, load balancer, and frequency and voltage regulator.
- 1 February 2006
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 34 (2) , 141-157
A Voltage and Frequency Controller for Self-Excited Induction Generators
This article describes a controller for voltage and frequency control of self-excited induction generator (SEIG) supplying static/dynamic, balanced/unbalanced loads. The controller is a combination of a three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC-VSI) and a high frequency DC chopper, which keeps the generated voltage and frequency constant in spite of change in consumer loads. A mathematical model of the SEIG with this controller supplying different types of loads is developed for predicting the behavior of the system under transient and dynamic conditions. The simulated results show that generated frequency and voltage remain constant with change in load. The proposed controller acts as reactive power compensator, harmonic eliminator, load balancer, and frequency and voltage regulator.
- 8 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1109-1114 Vol.3
Modelling and analysis of STATCOM based voltage regulator for self-excited induction generator with unbalanced loads
This paper presents an analysis of the three-phase self-excited induction generator (SEIG) with static-compensator (STATCOM) as a voltage regulator. Current controlled voltage source inverter (CC-VSI) is used as STATCOM, which provides fast dynamic response to maintain constant voltage at SEIG terminals during severe load perturbations and acts as a source and sink of reactive power. The performance equations are derived using d-q variable in stationary reference frame to develop a mathematical model of SEIG-STATCOM system feeding unbalanced loads. Transient analysis of the SEIG-STATCOM system is carried out for voltage build-up; switching in STATCOM, application and removal of balanced/unbalanced resistive/reactive loads. The STATCOM compensates the unbalanced load and keeps the generating system balanced while maintaining constant AC terminal voltage.
- 8 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1109-1114 Vol.3
Modelling and analysis of STATCOM based voltage regulator for self-excited induction generator with unbalanced loads
This paper presents an analysis of the three-phase self-excited induction generator (SEIG) with static-compensator (STATCOM) as a voltage regulator. Current controlled voltage source inverter (CC-VSI) is used as STATCOM, which provides fast dynamic response to maintain constant voltage at SEIG terminals during severe load perturbations and acts as a source and sink of reactive power. The performance equations are derived using d-q variable in stationary reference frame to develop a mathematical model of SEIG-STATCOM system feeding unbalanced loads. Transient analysis of the SEIG-STATCOM system is carried out for voltage build-up; switching in STATCOM, application and removal of balanced/unbalanced resistive/reactive loads. The STATCOM compensates the unbalanced load and keeps the generating system balanced while maintaining constant AC terminal voltage.