EMEitan Melamed

Eitan Melamed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eitan Melamed has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Ben Shamian

    Department of Orthopaedic Surgery, University of Medicine and Dentistry of New Jersey, Doctor's Office Center 90 Bergen Street, Newark, NJ 07101-1709 USA

    1 shared publication
  • Benhoor Shamian

    New York University Hospital for Joint Diseases, New York, NY; Woodhull Medical Center, Brooklyn, NY; Movement Analysis Laboratory, Istituto Ortopedico Rizzoli, Bologna, Italy; Joint Motion Laboratory, Department of Orthopedic Surgery, Rutgers New Jersey Medical School, Newark, NJ; Biomedical Engineering Department, School of Engineering, Rutgers University, New Brunswick, NJ

    1 shared publication
  • Brenon Abernathie

    Division of Plastic Surgery, Department of Surgery, University of Medicine and Dentistry of New Jersey, 140 Bergen Street, Suite E1620, Newark, NJ 07101-1709 USA

    1 shared publication
  • Bryan G. Beutel

    Department of Primary Care, Kansas City University College of Medicine, Kansas City, Missouri, United States

    1 shared publication
  • Frank Liporace

    Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, USA

    1 shared publication
  • John T. Capo

    New York University Hospital for Joint Diseases, New York, NY; Woodhull Medical Center, Brooklyn, NY; Movement Analysis Laboratory, Istituto Ortopedico Rizzoli, Bologna, Italy; Joint Motion Laboratory, Department of Orthopedic Surgery, Rutgers New Jersey Medical School, Newark, NJ; Biomedical Engineering Department, School of Engineering, Rutgers University, New Brunswick, NJ

    1 shared publication

Latest Publications

  • Biomechanical Evaluation of 5 Fixation Devices for Proximal Interphalangeal Joint Arthrodesis

    by John T. Capo, Eitan Melamed, Benhoor Shamian, Scott R. Hadley, Whitney Ng Lai, Kenny Gerszberg, Steven Rivero, Paolo Caravaggi


  • The Use of Skin Substitutes in the Treatment of the Hand and Upper Extremity

    by John T. Capo, Kyle P. Kokko, Marco Rizzo, Julie E. Adams, Ben Shamian, Brenon Abernathie, Eitan Melamed

    The introduction of skin substitutes in the last decade has dramatically changed how we think about the concept of “non-healing” wounds. Their use has improved prognosis and reduced morbidity in the treatment of open wounds. This article aims to summarize the development of tissue-engineered skin substitutes, discuss their use, and highlight some specific applications in different clinical settings.


  • Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate

    by John T. Capo, Monika P. Debkowska, Frank Liporace, Bryan G. Beutel, Eitan Melamed

    Purpose The locking compression extra-articular distal humerus plate (EADHP) is an anatomically shaped, angular stable single-column fixation system for distal third humerus fractures. The purpose of this retrospective study was to evaluate clinical and radiographic outcomes after open reduction and internal fixation of distal humerus fractures with this device. Methods Twenty-one consecutive patients with distal humerus fractures were treated with the EADHP system between February 2006 and June 2012. Of these, 19 were clinically and radiographically evaluated after a mean follow-up of 10.4 months. Follow-up assessment included anteroposterior and lateral radiographs, assessment of range of motion (ROM), pain according to a visual analogue scale (VAS) and Disabilities of the Arm, Shoulder and Hand (DASH) score. Results All fractures demonstrated satisfactory reduction and healing at an average of 7.3 months. One patient showed post-operative sensory ulnar neuropathy that recovered completely, and nine patients had a preoperative radial nerve palsy, which recovered spontaneously following exploration and plating. Mean post-operative ROM was as follows: flexion 126°, extension −7°, pronation 82° and supination 83°. The VAS score was zero points in eight patients, while the mean DASH score was 25.8 points. Conclusions For extra-articular distal humerus fractures, including high-energy injuries often seen in gunshot wounds or motor vehicle injuries, the anatomically shaped angular stable single-column plate provides satisfactory clinical and radiographic results and serves as a valuable tool in the treatment of these injuries.