TZTuan Zaharinie

Tuan Zaharinie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tuan Zaharinie has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microstructural evolution and mechanical properties of hot-rolled duplex stainless steel after exposure to elevated temperatures

    by Haitham Abdallah Khamis AL Adawani, Tuan Zaharinie Tuan Zahari, Muhammad Khairi Faiz Bin Ahmad Hairuddin

    The dual-phase ( γ / α ) microstructure of duplex stainless steel (DSS) delivers high strength and excellent localized corrosion resistance for structural applications. This study establishes a comparative experimental dataset for the residual mechanical performance and phase transformation kinetics of DSSs. This study investigates the combined effects of elevated temperature exposure and cooling methods on the microstructural stability and residual mechanical properties of hot-rolled EN 1.4162 and EN 1.4462 DSSs. Mechanical characterization revealed that rapid water quenching preserved the highest strength retention, whereas slow furnace cooling (FC) induced the greatest temperature sensitivity and strength loss. Air-cooled samples exhibited a unique response, showing significant strength reduction at intermediate temperatures but maximum ductility at 900 ° C, with ultimate strain values reaching 30% for EN 1.4162 and 25% for EN 1.4462. X-ray diffraction (XRD) showed that EN 1.4162 and EN 1.4462 retained dominant γ + α duplex reflections after 500 ° C exposure, regardless of cooling condition, indicating that it did not produce substantial XRD-detectable secondary-phase formation. In contrast, exposure at 900 ° C, especially followed by slow FC, produced additional reflections in both grades. For EN 1.4162, numerous peaks appeared within the 30° – 65° 2 θ range, while EN 1.4462 showed additional peaks within the 30° – 39° and 52° – 64° 2 θ ranges, indicating secondary-phase precipitation associated with σ phase, χ phase, chromium nitrides, and carbides. SEM-EDS observations further indicated that rapid cooling mainly produced oxidation- and thermal-stress-related cracking on the prepared observation surface, whereas FC produced more pronounced precipitate-containing microstructural regions with Cr/Mo-enriched compositions. These findings demonstrate that cooling rate is a decisive factor in governing the phase equilibrium and mechanical performance of duplex alloys under the investigated thermal exposure and cooling conditions.

  • Open Access

    Heat transfer enhancement of polished laser-textured copper surfaces in saturated pool boiling

    by Luvindran Sugumaran, Mohd Nashrul Mohd Zubir, Kazi Salim Newaz, Tuan Zaharinie, Suazlan Mt Aznam, Aiman Mohd Halil, Shekh Abdullah, Kaleemullah Shaikh, Norhafizan Ahmad


  • Finite Element Analysis of the Residual Mechanical Behaviour of Cold-Worked Austenitic Stainless Steel Reinforcing Bars after Exposure to Elevated Temperatures

    by Haitham Al Adawani, Tuan Zaharinie Binti Tuan Zahari, Muhammad Khairi Faiz Ahmad Hairuddin

    Austenitic stainless steels, specifically AISI 304 (EN 1.4301), are increasingly utilized in structural and architectural engineering due to their superior corrosion resistance and durability. However, the residual performance of cold-worked stainless-steel reinforcement after exposure to elevated temperatures remains a critical concern for structural safety assessments. This study presents a comprehensive finite element (FE) analysis aimed at predicting the residual mechanical behavior of cold-worked AISI 304 reinforcing bars. The numerical framework incorporates user-defined material parameters within an isotropic elastic model coupled with a multi-linear isotropic hardening model. The predictive capability of these models was evaluated against experimental data across three cooling regimes: Water Quenching (Q), Air Cooling (A), and Slow Furnace Cooling (S). The results demonstrate a robust correlation between the numerical simulations and experimental observations for both virgin and thermally exposed materials. The FE models achieved high precision, with discrepancies in ultimate tensile strength (𝑓ᵤ) generally restricted to less than 1.3%. The deviation in the 0.2% proof strength (𝑓0.2p) was maintained within 6.5% for the majority of cases, with minor exceptions reaching 8.01% for rapid water cooling at 700 °C and 6.53% for slow cooling at 900 °C. the findings indicate that the proposed modeling approach effectively captures the complex stress-strain response and total strain components across diverse thermal histories. This study provides a validated numerical tool for the structural fire engineering community to assess the post-fire capacity of stainless-steel reinforced structures with high confidence.

  • Effects of Various Environmental Conditions on the Stability of Single-Layer Alginate Microcapsules

    by Nur Syazana Aziz, Muhamad Nizar Amir, Swee Seong Tang, Tuan Zaharinie, Suriani Ibrahim

  • Optimised 3D Modelling for Additive Manufacturing of Copper-10Tin Open-Cell Metal Foam

    by Robert Chukwuemeka, Nur Amirah Mohd Zahri, Tuan Zaharinie, Muhammad Farid Syazwan Hassan, Muhamad Naqiuddin Ab Wahab

  • Brazing of Porous Nickel to Copper and Stainless Steel: Microstructure and Mechanical Properties

    by Tuan Zaharinie, Muhammad Amirul Ikmal, Ramizah Rozaimay, Tadashi Ariga

    A porous nickel (Ni) was brazed to copper (Cu) and stainless steel 304 (SS304) using VZ2250 and MBF67 brazing filler metal with a composition of 77.4Cu-9.3Sn-7.0Ni-6.3P and 64.5Ni-25Cr-6P-1.5Si (Cu: Copper, Sn: Tin, Ni: Nickel, P: Phosphorus, Cr: Chromium, Si: Silicon), respectively for joint microstructure and mechanical properties analysis. Porous Ni with a pore density of 15 pores per inch (PPI) was sandwiched between Cu/VZ2250 and MBF67/SS304. A brazed joint of Cu/Porous Ni/SS304 with VZ2250 and MBF67 brazing filler metal was prepared in a high vacuum furnace at different brazing times of 5, 10, and 15 minutes for 1015 °C with a heating and cooling rate of 10 °C/min, respectively for comparison purpose. The microstructure and mechanical properties of the brazed joint were investigated to identify the joint ability after the brazing process. Scanning Electron Microscope (SEM) equipped with Energy Dispersive X-Ray Spectroscopy (EDS) confirmed the interfacial microstructure by the formation of the diffusion filler metal (dark grey colour) for the Cu/Porous Ni/SS304 with VZ2250 and MBF67 brazing filler metal. For shear strength tests, the value decreases with an increase in the brazing time. The shear strength tests for the brazed joint of Cu/Porous Ni/SS304 with VZ2250 and MBF67 brazing filler metal show the maximum shear strength test value can be achieved for the brazing time of 5 minutes. The decreasing shear strength value was observed with differences in structural data of porous Ni due to the softening after the brazing process. Keywords: Brazing, Microstructure, Porous Nickel, Shear Strength.


  • An experimental study of heat exchanger based on metal foam, fin, and thermal interface material (TIM)

    by P. Ganesan, Fathiah Zaib, Tuan Zaharinie

    This paper presents an experimental study on heat exchangers based on fins, open-cell metal foam and thermal interface material (TIM). Experiments were conducte This paper presents an experimental study on heat exchangers based on fins, open-cell metal foam and thermal interface material (TIM). Experiments were conducte

  • Open Access

    Investigation on Microstructure and Compressive Strength of Brazing Porous Nickel to Copper and Stainless Steel

    by Ramizah Rozaimay, Tuan Zaharinie Tuan Zahari, Yose Fachmi Buys, Poo Balan Ganesan, Zainul Huda, Tadashi Ariga

    This paper investigates the effects of brazing temperatures on the microstructure and compressive strength for brazing porous nickel to copper and stainless steel using VZ2250 as the brazing filler metal. A high vacuum furnace is used to braze the samples. Three different brazing process parameters were set with a heating and cooling rate of 10°C/min, respectively. The characteristics of the joint interface have been investigated to evaluate the performance of the brazed samples by use of scanning electron microscope, energy-dispersive X-Ray spectroscope, X-Ray diffractometer, and Instron Universal Testing machine. The data obtained has been quantitively analyzed to confirm the diffusion of the BFM during the brazing process. It has been found that the diffusion process resulted in an increase in the rigidity of the porous Ni. The compressive strength tests for the brazed joint showed that the maximum compressive strength can be achieved for brazing at 680°C. The highest compressive strength value has been justified by quantitative analysis of the microstructural data. It has been proved that the VZ2250 BFM effectively diffused into the porous Ni at the brazing temperature of 680°C; Cu3P and Cu6Sn5 were detected at the brazed Interface 1, whereas MnNi3 phase at the brazed Interface 2.


  • Effect of deposition temperature on topography and electrochemical water oxidation of NiO thin films

    by Khadija Munawar, Muhammad Adil Mansoor, Rabia Naeem, Muhammad Rizwan, Muhammad Shakeel Ahmad, Tuan Zaharinie, Mohd Nashrul Mohd Zubir, Zarina Aspanut