Rong Xue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rong Xue has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
Yan Zhuo
State Key Laboratory of Cognitive Science and Mental Health Institute of Biophysics, Chinese Academy of Sciences Beijing China
9 shared publicationsJing An
Digital Department Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen China
6 shared publicationsBo Wang
State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics Chinese Academy of Sciences Beijing China
5 shared publicationsKaibao Sun
State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics Chinese Academy of Sciences Beijing China
5 shared publicationsXinqiang Yan
Beijing Engineering Research Center of Radiographic Techniques and Equipment
5 shared publicationsZhentao Zuo
State Key Laboratory of Cognitive Science and Mental Health Institute of Biophysics, Chinese Academy of Sciences Beijing China
5 shared publications
Latest Publications
- Open Access
- 9 November 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 1944-1958
Data Stitching for Dynamic Field Monitoring With NMR Probes
Purpose: To propose a new method for characterizing sequences with higher resolution or readout length than allowed by standard field monitoring approaches. Methods: Our proposed method was devised to characterize entire readout gradients by stitching multiple segment‐specific dynamic field measurements obtained across a matched number of consecutive TRs corresponding to a certain segmentation of the readout gradient. The utility of our proposed stitching method for high‐order dynamic field measurements was illustrated using 2D spiral sequences. It was first demonstrated at 10.5 T and then at 7 T using both simulated and experimental MRI data. At 10.5 T, two extreme spiral readout scenarios were considered where standard field monitoring did not work. Our method was then validated in humans at 7 T, where spiral sequences were employed for brain imaging. At 7 T, our method was further compared against gradient impulse response function (GIRF)‐based trajectory prediction. Results: At 10.5 T, our stitching method outperformed the standard approach, producing plausible dynamic field measurements throughout entire readouts. At 7 T, it produced nearly identical measurements for one readout where standard field monitoring also worked; for another readout when standard field monitoring did not work, it still produced sensible field measurements, improving image reconstruction for both simulated and experimental MRI data. Conclusion: Our proposed stitching method provides an effective means to characterize challenging imaging gradients using commercially available hardware and without assuming a linear gradient system, thereby having utility for many applications especially those aiming for ultrahigh‐resolution MRI at ultrahigh field.
- 9 November 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 1944-1958
Open AccessData Stitching for Dynamic Field Monitoring With NMR Probes
Purpose: To propose a new method for characterizing sequences with higher resolution or readout length than allowed by standard field monitoring approaches. Methods: Our proposed method was devised to characterize entire readout gradients by stitching multiple segment‐specific dynamic field measurements obtained across a matched number of consecutive TRs corresponding to a certain segmentation of the readout gradient. The utility of our proposed stitching method for high‐order dynamic field measurements was illustrated using 2D spiral sequences. It was first demonstrated at 10.5 T and then at 7 T using both simulated and experimental MRI data. At 10.5 T, two extreme spiral readout scenarios were considered where standard field monitoring did not work. Our method was then validated in humans at 7 T, where spiral sequences were employed for brain imaging. At 7 T, our method was further compared against gradient impulse response function (GIRF)‐based trajectory prediction. Results: At 10.5 T, our stitching method outperformed the standard approach, producing plausible dynamic field measurements throughout entire readouts. At 7 T, it produced nearly identical measurements for one readout where standard field monitoring also worked; for another readout when standard field monitoring did not work, it still produced sensible field measurements, improving image reconstruction for both simulated and experimental MRI data. Conclusion: Our proposed stitching method provides an effective means to characterize challenging imaging gradients using commercially available hardware and without assuming a linear gradient system, thereby having utility for many applications especially those aiming for ultrahigh‐resolution MRI at ultrahigh field.
- 20 August 2025
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 46 (2) , 508-520
Feasibility of relaxation-exchange magnetic resonance imaging (REXI) for measuring water exchange across the blood–CSF barrier in the human choroid plexus
The choroid plexus (CP) is important for cerebrospinal fluid (CSF) secretion and forms the blood–CSF barrier (BCSFB), which is essential for brain homeostasis. However, noninvasive methods for evaluating BCSFB function remain limited. Previously, we introduced a novel magnetic resonance imaging (MRI) technique, relaxation-exchange MRI (REXI), to quantify water exchange between CP and CSF in rats by leveraging the substantial difference in transverse relaxation times between CP tissue and CSF. Here, we adapted REXI to human applications by implementing segmented echo-planar imaging readout for enhanced acquisition speed, optimizing key parameters based on the Cramér–Rao lower bound, and refining the analysis methodology. We conducted simulations and phantom experiments for methodological validation. Subsequently, we performed a scan–rescan experiment in healthy volunteers (n = 6, mean-age ∼22 years), revealing relatively good repeatability in measurements of the apparent water exchange rate k BCSFB (intraclass correlation coefficient = 0.84). REXI detected a 34% decrease in k BCSFB among middle-aged healthy adults (n = 6, mean-age ∼55 years) compared with young healthy adults (n = 9, mean-age ∼23 years, p = 0.0048). These results demonstrate the feasibility of REXI in quantifying water exchange in human CP in vivo, providing a promising tool for future investigations of BCSFB function.
- 20 August 2025
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 46 (2) , 508-520
Feasibility of relaxation-exchange magnetic resonance imaging (REXI) for measuring water exchange across the blood–CSF barrier in the human choroid plexus
The choroid plexus (CP) is important for cerebrospinal fluid (CSF) secretion and forms the blood–CSF barrier (BCSFB), which is essential for brain homeostasis. However, noninvasive methods for evaluating BCSFB function remain limited. Previously, we introduced a novel magnetic resonance imaging (MRI) technique, relaxation-exchange MRI (REXI), to quantify water exchange between CP and CSF in rats by leveraging the substantial difference in transverse relaxation times between CP tissue and CSF. Here, we adapted REXI to human applications by implementing segmented echo-planar imaging readout for enhanced acquisition speed, optimizing key parameters based on the Cramér–Rao lower bound, and refining the analysis methodology. We conducted simulations and phantom experiments for methodological validation. Subsequently, we performed a scan–rescan experiment in healthy volunteers (n = 6, mean-age ∼22 years), revealing relatively good repeatability in measurements of the apparent water exchange rate k BCSFB (intraclass correlation coefficient = 0.84). REXI detected a 34% decrease in k BCSFB among middle-aged healthy adults (n = 6, mean-age ∼55 years) compared with young healthy adults (n = 9, mean-age ∼23 years, p = 0.0048). These results demonstrate the feasibility of REXI in quantifying water exchange in human CP in vivo, providing a promising tool for future investigations of BCSFB function.
- 1 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (9) , e70110
Exploring IVIM‐DKI and DKI for Assessing Microvascular and Microstructural Changes After Traumatic Brain Injury
Traumatic brain injury (TBI) is a major public health concern, but no reliable markers of injury are available. Axonal and microvascular changes are common after TBI, and diffusion MRI offers sensitivity to both. Diffusion kurtosis imaging (DKI) probes tissue microstructure, while intravoxel incoherent motion (IVIM) reflects microvascular flows. This study evaluated whether DKI or combined IVIM‐DKI analysis could detect microstructural and microvascular alterations after TBI and compared the sensitivity of these methods to the standard diffusion tensor imaging (DTI) and IVIM models. Longitudinal DKI and IVIM‐DKI changes were investigated following controlled cortical impact (CCI) in mice at 3, 10, and 22 days post‐injury. For this, parametric maps were obtained which for DKI included fractional anisotropy (FA), axial, radial, and mean diffusivity (AD, RD, and MD), axial, radial, and mean kurtosis (AK, RK, and MK). For IVIM‐DKI, we obtain perfusion fraction (f), pseudo‐diffusion coefficient (D*), diffusivity (D), and powder kurtosis (). Additionally, results for the non‐kurtosis metrics were compared to results for the corresponding metrics as estimated by the standard DTI and IVIM models. Widespread increases in MD, AD, and RD were present in white and gray matter on Day 3 post‐injury. On Day 10, these increases were replaced by focally decreased FA and AD in white matter, and increased f in the ipsilateral cortex. On Day 22, decreases in FA and AD were progressively widespread in white matter and accompanied by decreased MD, MK, AK, and RK. Standard DTI revealed less widespread differences at all time points, and standard IVIM detected no significant differences in f. These results show DKI and IVIM‐DKI as promising tools for assessing microstructural and microvascular alterations after TBI. DKI captured widespread white matter changes and early gray matter alterations, while IVIM‐DKI detected intermediate changes in f in gray matter. Both methods captured additional injury‐related differences compared to standard DTI and IVIM.
- 1 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (9) , e70110
Exploring IVIM‐DKI and DKI for Assessing Microvascular and Microstructural Changes After Traumatic Brain Injury
Traumatic brain injury (TBI) is a major public health concern, but no reliable markers of injury are available. Axonal and microvascular changes are common after TBI, and diffusion MRI offers sensitivity to both. Diffusion kurtosis imaging (DKI) probes tissue microstructure, while intravoxel incoherent motion (IVIM) reflects microvascular flows. This study evaluated whether DKI or combined IVIM‐DKI analysis could detect microstructural and microvascular alterations after TBI and compared the sensitivity of these methods to the standard diffusion tensor imaging (DTI) and IVIM models. Longitudinal DKI and IVIM‐DKI changes were investigated following controlled cortical impact (CCI) in mice at 3, 10, and 22 days post‐injury. For this, parametric maps were obtained which for DKI included fractional anisotropy (FA), axial, radial, and mean diffusivity (AD, RD, and MD), axial, radial, and mean kurtosis (AK, RK, and MK). For IVIM‐DKI, we obtain perfusion fraction (f), pseudo‐diffusion coefficient (D*), diffusivity (D), and powder kurtosis (). Additionally, results for the non‐kurtosis metrics were compared to results for the corresponding metrics as estimated by the standard DTI and IVIM models. Widespread increases in MD, AD, and RD were present in white and gray matter on Day 3 post‐injury. On Day 10, these increases were replaced by focally decreased FA and AD in white matter, and increased f in the ipsilateral cortex. On Day 22, decreases in FA and AD were progressively widespread in white matter and accompanied by decreased MD, MK, AK, and RK. Standard DTI revealed less widespread differences at all time points, and standard IVIM detected no significant differences in f. These results show DKI and IVIM‐DKI as promising tools for assessing microstructural and microvascular alterations after TBI. DKI captured widespread white matter changes and early gray matter alterations, while IVIM‐DKI detected intermediate changes in f in gray matter. Both methods captured additional injury‐related differences compared to standard DTI and IVIM.
- Open Access
- 29 June 2025
- Published by Wiley in Psych Journal
- Vol. 14 (4) , 560-572
Anterior Cingulate Cortex Glutamate Levels and Sensory Integration Are Associated in Individuals With Social Anhedonia: A Comparison Between 3T and 7T MRS
Deficits in schizophrenia are linked to abnormalities in the glutamate (Glu) system, which are believed to result in neurological soft signs (NSS) and negative symptoms. This study investigated the relationship between Glu levels of the anterior cingulate cortex (ACC) and NSS, particularly sensory integration, in individuals with high and low levels of social anhedonia using 3 Tesla (T) and 7T Magnetic Resonance Spectroscopy (MRS). We recruited 16 participants with high social anhedonia and 18 with low social anhedonia and correlated their NSS scores with ACC Glu levels. While spectral quality metrics differed between field strengths, with 7T showing better spectral resolution and metabolite quantification reliability, both 3T and 7T data showed consistent correlation patterns. Our findings demonstrated that higher ACC Glu levels were associated with poorer sensory integration in high levels of social anhedonia across both field strengths, supported by both Pearson and Spearman rank correlations. Notably, the opposite pattern of association was found in people with low levels of social anhedonia at 7T. The Glu systems may be the common mechanisms for negative symptoms and NSS, highlighting its potential as a therapeutic target.
- 29 June 2025
- Published by Wiley in Psych Journal
- Vol. 14 (4) , 560-572
Open AccessAnterior Cingulate Cortex Glutamate Levels and Sensory Integration Are Associated in Individuals With Social Anhedonia: A Comparison Between 3T and 7T MRS
Deficits in schizophrenia are linked to abnormalities in the glutamate (Glu) system, which are believed to result in neurological soft signs (NSS) and negative symptoms. This study investigated the relationship between Glu levels of the anterior cingulate cortex (ACC) and NSS, particularly sensory integration, in individuals with high and low levels of social anhedonia using 3 Tesla (T) and 7T Magnetic Resonance Spectroscopy (MRS). We recruited 16 participants with high social anhedonia and 18 with low social anhedonia and correlated their NSS scores with ACC Glu levels. While spectral quality metrics differed between field strengths, with 7T showing better spectral resolution and metabolite quantification reliability, both 3T and 7T data showed consistent correlation patterns. Our findings demonstrated that higher ACC Glu levels were associated with poorer sensory integration in high levels of social anhedonia across both field strengths, supported by both Pearson and Spearman rank correlations. Notably, the opposite pattern of association was found in people with low levels of social anhedonia at 7T. The Glu systems may be the common mechanisms for negative symptoms and NSS, highlighting its potential as a therapeutic target.
- 17 April 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6) , e70042
Res‐Net‐Based Modeling and Morphologic Analysis of Deep Medullary Veins Using Multi‐Echo GRE at 7 T MRI
The pathological changes in deep medullary veins (DMVs) have been reported in various diseases. However, accurate modeling and quantification of DMVs remain challenging. We aim to propose and assess an automated approach for modeling and quantifying DMVs at 7 Tesla (7 T) MRI. A multi‐echo‐input Res‐Net was developed for vascular segmentation, and a minimum path loss function was used for modeling and quantifying the geometric parameter of DMVs. Twenty‐one patients diagnosed as subcortical vascular dementia (SVaD) and 20 condition matched controls were included in this study. The amplitude and phase images of gradient echo with five echoes were acquired at 7 T. Ten GRE images were manually labeled by two neurologists and compared with the results obtained by our proposed method. Independent samples t test and Pearson correlation were used for statistical analysis in our study, and p value < 0.05 was considered significant. No significant offset was found in centerlines obtained by human labeling and our algorithm (p = 0.734). The length difference between the proposed method and manual labeling was smaller than the error between different clinicians (p < 0.001). Patients with SVaD exhibited fewer DMVs (mean difference = −60.710 ± 21.810, p = 0.011) and higher curvature (mean difference = 0.12 ± 0.022, p < 0.0001), corresponding to their higher Vascular Dementia Assessment Scale‐Cog (VaDAS‐Cog) scores (mean difference = 4.332 ± 1.992, p = 0.036) and lower Mini‐Mental State Examination (MMSE) (mean difference = −3.071 ± 1.443, p = 0.047). The MMSE scores were positively correlated with the numbers of DMVs (r = 0.437, p = 0.037) and were negatively correlated with the curvature (r = −0.426, p = 0.042). In summary, we proposed a novel framework for automated quantifying the morphologic parameters of DMVs. These characteristics of DMVs are expected to help the research and diagnosis of cerebral small vessel diseases with DMV lesions.
- 17 April 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6) , e70042
Res‐Net‐Based Modeling and Morphologic Analysis of Deep Medullary Veins Using Multi‐Echo GRE at 7 T MRI
The pathological changes in deep medullary veins (DMVs) have been reported in various diseases. However, accurate modeling and quantification of DMVs remain challenging. We aim to propose and assess an automated approach for modeling and quantifying DMVs at 7 Tesla (7 T) MRI. A multi‐echo‐input Res‐Net was developed for vascular segmentation, and a minimum path loss function was used for modeling and quantifying the geometric parameter of DMVs. Twenty‐one patients diagnosed as subcortical vascular dementia (SVaD) and 20 condition matched controls were included in this study. The amplitude and phase images of gradient echo with five echoes were acquired at 7 T. Ten GRE images were manually labeled by two neurologists and compared with the results obtained by our proposed method. Independent samples t test and Pearson correlation were used for statistical analysis in our study, and p value < 0.05 was considered significant. No significant offset was found in centerlines obtained by human labeling and our algorithm (p = 0.734). The length difference between the proposed method and manual labeling was smaller than the error between different clinicians (p < 0.001). Patients with SVaD exhibited fewer DMVs (mean difference = −60.710 ± 21.810, p = 0.011) and higher curvature (mean difference = 0.12 ± 0.022, p < 0.0001), corresponding to their higher Vascular Dementia Assessment Scale‐Cog (VaDAS‐Cog) scores (mean difference = 4.332 ± 1.992, p = 0.036) and lower Mini‐Mental State Examination (MMSE) (mean difference = −3.071 ± 1.443, p = 0.047). The MMSE scores were positively correlated with the numbers of DMVs (r = 0.437, p = 0.037) and were negatively correlated with the curvature (r = −0.426, p = 0.042). In summary, we proposed a novel framework for automated quantifying the morphologic parameters of DMVs. These characteristics of DMVs are expected to help the research and diagnosis of cerebral small vessel diseases with DMV lesions.
- Open Access
- 26 November 2024
- Published by Springer Nature in Fluids and Barriers of the CNS
- Vol. 21 (1) , 1-13
Relaxation-exchange magnetic resonance imaging (REXI): a non-invasive imaging method for evaluating trans-barrier water exchange in the choroid plexus
The choroid plexus (CP) plays a crucial role in cerebrospinal fluid (CSF) production and brain homeostasis. However, non-invasive imaging techniques to assess its function remain limited. This study was conducted to develop a novel, contrast-agent-free MRI technique, termed relaxation-exchange magnetic resonance imaging (REXI), for evaluating CP-CSF water transport, a potential biomarker of CP function. REXI utilizes the inherent and large difference in magnetic resonance transverse relaxation times (T2s) between CP tissue (e.g., blood vessels and epithelial cells) and CSF. It uses a filter block to remove most CP tissue magnetization (shorter T2), a mixing block for CP-CSF water exchange with mixing time tm, and a detection block with multi-echo acquisition to determine the CP/CSF component fraction after exchange. The REXI pulse sequence was implemented on a 9.4 T preclinical MRI scanner. For validation of REXI’s ability to measure exchange, we conducted preliminary tests on urea-water proton-exchange phantoms with various pH levels. We measured the steady-state water efflux rate from CP to CSF in rats and tested the sensitivity of REXI in detecting CP dysfunction induced by the carbonic anhydrase inhibitor acetazolamide. REXI pulse sequence successfully captured changes in the proton exchange rate (from short-T2 component to long-T2 component [i.e., ksl]) of urea-water phantoms at varying pH, demonstrating its sensitivity to exchange processes. In rat CP, REXI significantly suppressed the CP tissue signal, reducing the short-T2 fraction (fshort) from 0.44 to 0.23 (p < 0.0001), with significant recovery to 0.28 after a mixing time of 400 ms (p = 0.014). The changes in fshort at various mixing times can be accurately described by a two-site exchange model, yielding a steady-state water efflux rate from CP to CSF (i.e., kbc) of 0.49 s−1. A scan-rescan experiment demonstrated that REXI had excellent reproducibility in measuring kbc (intraclass correlation coefficient = 0.90). Notably, acetazolamide-induced CSF reduction resulted in a 66% decrease in kbc within rat CP. This proof-of-concept study demonstrates the feasibility of REXI for measuring trans-barrier water exchange in the CP, offering a promising biomarker for future assessments of CP function.
- 26 November 2024
- Published by Springer Nature in Fluids and Barriers of the CNS
- Vol. 21 (1) , 1-13
Open AccessRelaxation-exchange magnetic resonance imaging (REXI): a non-invasive imaging method for evaluating trans-barrier water exchange in the choroid plexus
The choroid plexus (CP) plays a crucial role in cerebrospinal fluid (CSF) production and brain homeostasis. However, non-invasive imaging techniques to assess its function remain limited. This study was conducted to develop a novel, contrast-agent-free MRI technique, termed relaxation-exchange magnetic resonance imaging (REXI), for evaluating CP-CSF water transport, a potential biomarker of CP function. REXI utilizes the inherent and large difference in magnetic resonance transverse relaxation times (T2s) between CP tissue (e.g., blood vessels and epithelial cells) and CSF. It uses a filter block to remove most CP tissue magnetization (shorter T2), a mixing block for CP-CSF water exchange with mixing time tm, and a detection block with multi-echo acquisition to determine the CP/CSF component fraction after exchange. The REXI pulse sequence was implemented on a 9.4 T preclinical MRI scanner. For validation of REXI’s ability to measure exchange, we conducted preliminary tests on urea-water proton-exchange phantoms with various pH levels. We measured the steady-state water efflux rate from CP to CSF in rats and tested the sensitivity of REXI in detecting CP dysfunction induced by the carbonic anhydrase inhibitor acetazolamide. REXI pulse sequence successfully captured changes in the proton exchange rate (from short-T2 component to long-T2 component [i.e., ksl]) of urea-water phantoms at varying pH, demonstrating its sensitivity to exchange processes. In rat CP, REXI significantly suppressed the CP tissue signal, reducing the short-T2 fraction (fshort) from 0.44 to 0.23 (p < 0.0001), with significant recovery to 0.28 after a mixing time of 400 ms (p = 0.014). The changes in fshort at various mixing times can be accurately described by a two-site exchange model, yielding a steady-state water efflux rate from CP to CSF (i.e., kbc) of 0.49 s−1. A scan-rescan experiment demonstrated that REXI had excellent reproducibility in measuring kbc (intraclass correlation coefficient = 0.90). Notably, acetazolamide-induced CSF reduction resulted in a 66% decrease in kbc within rat CP. This proof-of-concept study demonstrates the feasibility of REXI for measuring trans-barrier water exchange in the CP, offering a promising biomarker for future assessments of CP function.
- Open Access
- 23 March 2023
- Published by Oxford University Press (OUP) in Life Metabolism
- Vol. 2 (2) , load010
Ablation of Mea6/cTAGE5 in oligodendrocytes significantly impairs white matter structure and lipid content
Lipid-rich myelin is a special structure formed by oligodendrocytes wrapping neuronal axons. Abnormal myelin sheath is associated with many neurological diseases. Meningioma-expressed antigen 6 (Mea6)/cutaneous T cell lymphoma-associated antigen 5C (cTAGE5C) plays an important role in vesicle trafficking from the endoplasmic reticulum (ER) to Golgi, and conditional knockout (cKO) of Mea6 in the brain significantly affects neural development and brain function. However, whether the impaired brain function involves the development of oligodendrocytes and white matter beyond neurons remains unclear. In this study, by using different models of diffusion magnetic resonance imaging, we showed that cKO of Mea6 in oligodendrocytes leads to significant impairment of the gross and microstructure of the white matter, as well as a significant decrease of cholesterol and triglycerides in brains. Our lipidomic analysis of purified myelin sheath for the first time showed that Mea6 elimination in oligodendrocytes significantly altered the lipid composition in myelin lipidome, especially the proportion of very long-chain fatty acids (VLCFAs). In particular, the levels of most VLCFA-containing phosphatidylcholines were substantially lower in the myelin sheath of the cKO mice. The reduction of VLCFAs is likely due to the downregulated expression of elongation of very long-chain fatty acids (ELOVLs ). Our study of an animal model with white matter malformation and the comprehensive lipid profiling would provide clues for future studies of the formation of myelin sheath, myelin lipids, and the pathogenesis of white matter diseases.
- 23 March 2023
- Published by Oxford University Press (OUP) in Life Metabolism
- Vol. 2 (2) , load010
Open AccessAblation of Mea6/cTAGE5 in oligodendrocytes significantly impairs white matter structure and lipid content
Lipid-rich myelin is a special structure formed by oligodendrocytes wrapping neuronal axons. Abnormal myelin sheath is associated with many neurological diseases. Meningioma-expressed antigen 6 (Mea6)/cutaneous T cell lymphoma-associated antigen 5C (cTAGE5C) plays an important role in vesicle trafficking from the endoplasmic reticulum (ER) to Golgi, and conditional knockout (cKO) of Mea6 in the brain significantly affects neural development and brain function. However, whether the impaired brain function involves the development of oligodendrocytes and white matter beyond neurons remains unclear. In this study, by using different models of diffusion magnetic resonance imaging, we showed that cKO of Mea6 in oligodendrocytes leads to significant impairment of the gross and microstructure of the white matter, as well as a significant decrease of cholesterol and triglycerides in brains. Our lipidomic analysis of purified myelin sheath for the first time showed that Mea6 elimination in oligodendrocytes significantly altered the lipid composition in myelin lipidome, especially the proportion of very long-chain fatty acids (VLCFAs). In particular, the levels of most VLCFA-containing phosphatidylcholines were substantially lower in the myelin sheath of the cKO mice. The reduction of VLCFAs is likely due to the downregulated expression of elongation of very long-chain fatty acids (ELOVLs ). Our study of an animal model with white matter malformation and the comprehensive lipid profiling would provide clues for future studies of the formation of myelin sheath, myelin lipids, and the pathogenesis of white matter diseases.
- 3 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (3) , 1303-1313
Multi‐echo balanced SSFP with a sequential phase‐encoding order for functional MR imaging at 7T
Purpose: To develop a 2D multi‐echo passband balanced SSFP (bSSFP) sequence using an echo‐train readout with a sequential phase‐encoding order (sequential multi‐echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T.Methods: As images of sequential multi‐echo bSSFP exhibit multiple ghosts due to periodic k‐space modulations, a GRAPPA‐based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi‐echo bSSFP and conventional single‐echo bSSFP. Submillimeter‐resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi‐echo bSSFP, conventional single‐echo bSSFP and standard gradient‐echo EPI (GE‐EPI).Results: A higher mean structural similarity index was found between images of single‐echo bSSFP and multi‐echo bSSFP with a shorter echo train length (ETL). Multi‐echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA‐accelerated single‐echo bSSFP (R = 2). In submillimeter‐resolution fMRI experiments, multi‐echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA‐accelerated single‐echo bSSFP (R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t‐value and the number of significantly activated voxels were comparable between GE‐EPI and multi‐echo bSSFP (ETL = 3) that provides virtually distortion‐free functional images and inherits the activation patterns of conventional bSSFP.Conclusion: Sequential multi‐echo bSSFP (ETL = 3) is suitable for fast fMRI with submillimeter in‐plane resolution, and offers an option to accelerate bSSFP imaging without tSNR penalty like parallel imaging.
- 3 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (3) , 1303-1313
Multi‐echo balanced SSFP with a sequential phase‐encoding order for functional MR imaging at 7T
Purpose: To develop a 2D multi‐echo passband balanced SSFP (bSSFP) sequence using an echo‐train readout with a sequential phase‐encoding order (sequential multi‐echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T.Methods: As images of sequential multi‐echo bSSFP exhibit multiple ghosts due to periodic k‐space modulations, a GRAPPA‐based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi‐echo bSSFP and conventional single‐echo bSSFP. Submillimeter‐resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi‐echo bSSFP, conventional single‐echo bSSFP and standard gradient‐echo EPI (GE‐EPI).Results: A higher mean structural similarity index was found between images of single‐echo bSSFP and multi‐echo bSSFP with a shorter echo train length (ETL). Multi‐echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA‐accelerated single‐echo bSSFP (R = 2). In submillimeter‐resolution fMRI experiments, multi‐echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA‐accelerated single‐echo bSSFP (R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t‐value and the number of significantly activated voxels were comparable between GE‐EPI and multi‐echo bSSFP (ETL = 3) that provides virtually distortion‐free functional images and inherits the activation patterns of conventional bSSFP.Conclusion: Sequential multi‐echo bSSFP (ETL = 3) is suitable for fast fMRI with submillimeter in‐plane resolution, and offers an option to accelerate bSSFP imaging without tSNR penalty like parallel imaging.
- Open Access
- 25 April 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 986-1001
Tracking of rigid head motion duringMRIusing an EEGsystem
Purpose: To demonstrate a novel method for tracking of head movements during MRI using electroencephalography (EEG) hardware for recording signals induced by native imaging gradients.Theory and Methods: Gradient switching during simultaneous EEG–fMRI induces distortions in EEG signals, which depend on subject head position and orientation. When EEG electrodes are interconnected with high‐impedance carbon wire loops, the induced voltages are linear combinations of the temporal gradient waveform derivatives. We introduce head tracking based on these signals (CapTrack) involving 3 steps: (1) phantom scanning is used to characterize the target sequence and a fast calibration sequence; (2) a linear relation between changes of induced signals and head pose is established using the calibration sequence; and (3) induced signals recorded during target sequence scanning are used for tracking and retrospective correction of head movement without prolonging the scan time of the target sequence. Performance of CapTrack is compared directly to interleaved navigators.Results: Head‐pose tracking at 27.5 Hz during echo planar imaging (EPI) was demonstrated with close resemblance to rigid body alignment (mean absolute difference: [0.14 0.38 0.15]‐mm translation, [0.30 0.27 0.22]‐degree rotation). Retrospective correction of 3D gradient‐echo imaging shows an increase of average edge strength of 12%/−0.39% for instructed/uninstructed motion with CapTrack pose estimates, with a tracking interval of 1561 ms and high similarity to interleaved navigator estimates (mean absolute difference: [0.13 0.33 0.12] mm, [0.28 0.15 0.22] degrees).Conclusion: Motion can be estimated from recordings of gradient switching with little or no sequence modification, optionally in real time at low computational burden and synchronized to image acquisition, using EEG equipment already found at many research institutions.
- 25 April 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 986-1001
Open AccessTracking of rigid head motion duringMRIusing an EEGsystem
Purpose: To demonstrate a novel method for tracking of head movements during MRI using electroencephalography (EEG) hardware for recording signals induced by native imaging gradients.Theory and Methods: Gradient switching during simultaneous EEG–fMRI induces distortions in EEG signals, which depend on subject head position and orientation. When EEG electrodes are interconnected with high‐impedance carbon wire loops, the induced voltages are linear combinations of the temporal gradient waveform derivatives. We introduce head tracking based on these signals (CapTrack) involving 3 steps: (1) phantom scanning is used to characterize the target sequence and a fast calibration sequence; (2) a linear relation between changes of induced signals and head pose is established using the calibration sequence; and (3) induced signals recorded during target sequence scanning are used for tracking and retrospective correction of head movement without prolonging the scan time of the target sequence. Performance of CapTrack is compared directly to interleaved navigators.Results: Head‐pose tracking at 27.5 Hz during echo planar imaging (EPI) was demonstrated with close resemblance to rigid body alignment (mean absolute difference: [0.14 0.38 0.15]‐mm translation, [0.30 0.27 0.22]‐degree rotation). Retrospective correction of 3D gradient‐echo imaging shows an increase of average edge strength of 12%/−0.39% for instructed/uninstructed motion with CapTrack pose estimates, with a tracking interval of 1561 ms and high similarity to interleaved navigator estimates (mean absolute difference: [0.13 0.33 0.12] mm, [0.28 0.15 0.22] degrees).Conclusion: Motion can be estimated from recordings of gradient switching with little or no sequence modification, optionally in real time at low computational burden and synchronized to image acquisition, using EEG equipment already found at many research institutions.
- Open Access
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 107965-107975
Fast Diffusion Kurtosis Mapping of Human Brain at 7 Tesla With Hybrid Principal Component Analyses
Diffusion kurtosis has become an important magnetic resonance imaging (MRI) modality for non-invasively mapping the microstructural variations in living tissues. Theoretically, the spatial resolution of diffusion kurtosis imaging (DKI) can be significantly improved by acquiring data at ultra-high magnetic fields (UHF, ≤ 7 Tesla) because of the increased signal-to-noise ratios. However, issues such as increased susceptibility artefacts and rapid signal attenuation inherent in UHF-MRI have impeded the adoption of DKI in research and clinics. In this paper, we developed a new image reconstruction algorithm for fast DKI at UHF. By integrating the one-dimensional and two-dimensional principal component analysis and compressed sensing technologies, the new algorithm can reconstruct kurtosis maps from highly undersampled data. The technique was validated using randomly undersampled brain images with a control database of fully sampled DKI acquisitions from healthy human participants. We compared the technique with zero-filling Fourier transform and similar compressed sensing algorithms by evaluating the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) between images and assessing the reproducibility of results using the Bland-Altman method. We found that our methods can achieve at least a five-fold reduction in data acquisition time at UHF with high image quality. Moreover, the PSNR and SSIM of five diffusion metrics generated by our methods were superior to the other algorithms when the undersampling rate is high and the echo time is short. The proposed method can be valuable for fast functional and dynamic-contrast imaging techniques at 7 Tesla or higher.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 107965-107975
Open AccessFast Diffusion Kurtosis Mapping of Human Brain at 7 Tesla With Hybrid Principal Component Analyses
Diffusion kurtosis has become an important magnetic resonance imaging (MRI) modality for non-invasively mapping the microstructural variations in living tissues. Theoretically, the spatial resolution of diffusion kurtosis imaging (DKI) can be significantly improved by acquiring data at ultra-high magnetic fields (UHF, ≤ 7 Tesla) because of the increased signal-to-noise ratios. However, issues such as increased susceptibility artefacts and rapid signal attenuation inherent in UHF-MRI have impeded the adoption of DKI in research and clinics. In this paper, we developed a new image reconstruction algorithm for fast DKI at UHF. By integrating the one-dimensional and two-dimensional principal component analysis and compressed sensing technologies, the new algorithm can reconstruct kurtosis maps from highly undersampled data. The technique was validated using randomly undersampled brain images with a control database of fully sampled DKI acquisitions from healthy human participants. We compared the technique with zero-filling Fourier transform and similar compressed sensing algorithms by evaluating the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) between images and assessing the reproducibility of results using the Bland-Altman method. We found that our methods can achieve at least a five-fold reduction in data acquisition time at UHF with high image quality. Moreover, the PSNR and SSIM of five diffusion metrics generated by our methods were superior to the other algorithms when the undersampling rate is high and the echo time is short. The proposed method can be valuable for fast functional and dynamic-contrast imaging techniques at 7 Tesla or higher.