Tyler Steven Watters
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tyler Steven Watters has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Michael P. Bolognesi
Division of Orthopaedic Surgery, Department of Surgery, Duke University Medical Center, Durham, NC 27710. address for T.S. Watters
2 shared publicationsRhett K. Hallows
Intermountain Orthopedic Specialty Group, 370 East 9th Avenue, Suite 205, Salt Lake City, UT 84103
2 shared publicationsAdam Kaufman
1 shared publicationBrian E. Brigman
Duke University Medical Center
1 shared publicationDiane B. Covington
Duke University Medical Center
1 shared publicationDustin Hambright
Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina 27710, USA
1 shared publication
Latest Publications
- 1 December 2010
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 23 (04) , 237-240
Fracture of Highly Cross-linked All-Polyethylene Patella after Total Knee Arthroplasty
Recent advances in polyethylene fabrication have led to the introduction of highly cross-linked polyethylene tibial and patellar components for use in total knee arthroplasty (TKA) with the goal of reducing wear-related osteolysis. However, some reports suggest decreased mechanical strength as a result of the additional thermal and sterilization treatments in the manufacturing of implants. Complications related to the patella are among the most common causes of failure in TKA, but patellar component fracture is rare. The authors report a case of a highly cross-linked all-polyethylene patellar component that failed as a result of fracture in vivo in a patient 3 years after TKA.
- 1 December 2010
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 23 (04) , 237-240
Fracture of Highly Cross-linked All-Polyethylene Patella after Total Knee Arthroplasty
Recent advances in polyethylene fabrication have led to the introduction of highly cross-linked polyethylene tibial and patellar components for use in total knee arthroplasty (TKA) with the goal of reducing wear-related osteolysis. However, some reports suggest decreased mechanical strength as a result of the additional thermal and sterilization treatments in the manufacturing of implants. Complications related to the patella are among the most common causes of failure in TKA, but patellar component fracture is rare. The authors report a case of a highly cross-linked all-polyethylene patellar component that failed as a result of fracture in vivo in a patient 3 years after TKA.
- Open Access
- 1 November 2010
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (11) , 3126-3131
Case Report: Neuropathic Arthropathy of the Hip as a Sequela of Undiagnosed Tertiary Syphilis
Neuropathic arthropathy is characterized by rapidly progressive bone destruction in the setting of impaired nociceptive and proprioceptive innervation to the involved joint. It is seen most commonly in the foot and ankle, secondary to peripheral neuropathy in patients with diabetes mellitus. Other less common sites of involvement may include the knee, hip, shoulder, and spine, depending on the underlying etiology. Neuropathic arthropathy can be associated with tabes dorsalis, a unique manifestation of late, tertiary neurosyphilis that may arise in individuals with untreated syphilis many years after initial infection, and usually involves the knee, or less commonly, the hip. We report the case of a 73-year-old man with neuropathic arthropathy of the hip and tabes dorsalis attributable to previously undiagnosed tertiary syphilis. There was considerable delay in the diagnosis and unnecessary diagnostic testing owing to failure to consider syphilis as the cause. With the advent of effective antimicrobial therapy and public health campaigns, the relationship between untreated syphilis and neuropathic arthropathy has been primarily a historic point of interest. However, current epidemiologic research suggests a resurgence of syphilis in the United States, with an increased incidence of patients presenting with manifestations of tertiary syphilis from unidentified and untreated primary infections. Treatment options for neuropathic arthropathy of the hip are limited. Arthrodesis has had poor success and treatment with THA has had high complication rates. Syphilis is not merely a historic cause of neuropathic arthropathy. Neurosyphilis and tabes dorsalis should be considered in the differential diagnosis for patients presenting with rapid joint destruction consistent with Charcot arthropathy and no other apparent cause.
- 1 November 2010
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (11) , 3126-3131
Open AccessCase Report: Neuropathic Arthropathy of the Hip as a Sequela of Undiagnosed Tertiary Syphilis
Neuropathic arthropathy is characterized by rapidly progressive bone destruction in the setting of impaired nociceptive and proprioceptive innervation to the involved joint. It is seen most commonly in the foot and ankle, secondary to peripheral neuropathy in patients with diabetes mellitus. Other less common sites of involvement may include the knee, hip, shoulder, and spine, depending on the underlying etiology. Neuropathic arthropathy can be associated with tabes dorsalis, a unique manifestation of late, tertiary neurosyphilis that may arise in individuals with untreated syphilis many years after initial infection, and usually involves the knee, or less commonly, the hip. We report the case of a 73-year-old man with neuropathic arthropathy of the hip and tabes dorsalis attributable to previously undiagnosed tertiary syphilis. There was considerable delay in the diagnosis and unnecessary diagnostic testing owing to failure to consider syphilis as the cause. With the advent of effective antimicrobial therapy and public health campaigns, the relationship between untreated syphilis and neuropathic arthropathy has been primarily a historic point of interest. However, current epidemiologic research suggests a resurgence of syphilis in the United States, with an increased incidence of patients presenting with manifestations of tertiary syphilis from unidentified and untreated primary infections. Treatment options for neuropathic arthropathy of the hip are limited. Arthrodesis has had poor success and treatment with THA has had high complication rates. Syphilis is not merely a historic cause of neuropathic arthropathy. Neurosyphilis and tabes dorsalis should be considered in the differential diagnosis for patients presenting with rapid joint destruction consistent with Charcot arthropathy and no other apparent cause.
- 7 July 2010
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 92 (7) , 1666-1669
Pseudotumor with Superimposed Periprosthetic Infection Following Metal-on-Metal Total Hip Arthroplasty
Second-generation metal-on-metal bearing surfaces made of modern cobalt-chromium-molybdenum alloys are widely used for total hip arthroplasty in the United States1. While these bearing surfaces offer considerable advantages over conventional metal-on-polyethylene articulations, metal hypersensitivity reactions to these implants are an important, although uncommon, cause of failure2. This unique mode of failure, which has been reported with first-generation implants2,3 and subsequently in association with second-generation metal-on-metal bearing surfaces, appears to be caused by an immunologic delayed hypersensitivity response to metal particles4-6. This local tissue reaction, described as an aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL), was characterized by Willert et al.7 as having histologic features that include diffuse perivascular infiltrates of T and B lymphocytes and plasma cells, high endothelial venules, massive fibrin exudation, accumulation of macrophages with droplike inclusions, and infiltrates of eosinophilic granulocytes and necrosis. Histologically, high endothelial venules are characterized as vascular and/or lymphatic vessels with reactive endothelium, often seen in association with an inflammatory response. Willert et al. suggested that the possibility of such a reaction be considered when, following primary implantation of metal-on-metal implants, a patient reports the recurrence of preoperative pain and there is a marked joint effusion or the development of osteolysis in the absence of a suspicion of deep periprosthetic infection. A subsequent report, however, described this hypersensitivity reaction mimicking infection in a patient with elevated levels of inflammatory biomarkers who was later found to have no deep infection on revision8. We describe a patient with a failure of a metal-on-metal total hip replacement consistent with a metal hypersensitivity reaction who presented with a pseudotumor and massive lower-extremity edema secondary to extrinsic femoral vein compression and subsequently developed a superimposed deep periprosthetic infection prior to revision. To our knowledge, this has not …
- 7 July 2010
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 92 (7) , 1666-1669
Pseudotumor with Superimposed Periprosthetic Infection Following Metal-on-Metal Total Hip Arthroplasty
Second-generation metal-on-metal bearing surfaces made of modern cobalt-chromium-molybdenum alloys are widely used for total hip arthroplasty in the United States1. While these bearing surfaces offer considerable advantages over conventional metal-on-polyethylene articulations, metal hypersensitivity reactions to these implants are an important, although uncommon, cause of failure2. This unique mode of failure, which has been reported with first-generation implants2,3 and subsequently in association with second-generation metal-on-metal bearing surfaces, appears to be caused by an immunologic delayed hypersensitivity response to metal particles4-6. This local tissue reaction, described as an aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL), was characterized by Willert et al.7 as having histologic features that include diffuse perivascular infiltrates of T and B lymphocytes and plasma cells, high endothelial venules, massive fibrin exudation, accumulation of macrophages with droplike inclusions, and infiltrates of eosinophilic granulocytes and necrosis. Histologically, high endothelial venules are characterized as vascular and/or lymphatic vessels with reactive endothelium, often seen in association with an inflammatory response. Willert et al. suggested that the possibility of such a reaction be considered when, following primary implantation of metal-on-metal implants, a patient reports the recurrence of preoperative pain and there is a marked joint effusion or the development of osteolysis in the absence of a suspicion of deep periprosthetic infection. A subsequent report, however, described this hypersensitivity reaction mimicking infection in a patient with elevated levels of inflammatory biomarkers who was later found to have no deep infection on revision8. We describe a patient with a failure of a metal-on-metal total hip replacement consistent with a metal hypersensitivity reaction who presented with a pseudotumor and massive lower-extremity edema secondary to extrinsic femoral vein compression and subsequently developed a superimposed deep periprosthetic infection prior to revision. To our knowledge, this has not …
- 16 June 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (7) , 835-839
Lack of radiographic loosening signs in a hip resurfacing that failed by stem fracture
- 16 June 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (7) , 835-839
Lack of radiographic loosening signs in a hip resurfacing that failed by stem fracture