Emilie Hardy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emilie Hardy has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Rodrigues
DPHY, ONERA, Université Paris Saclay, F-92322 Châtillon, France
6 shared publications Pierre Touboul
DPHY, ONERA, Université Paris Saclay, F-92322 Châtillon, France
6 shared publications- Bruno Christophe
ONERA—The French Aerospace Lab, 29 avenue de la Division Leclerc, 92320 Châtillon, France
4 shared publications Gilles Métris
Université Côte d'Azur, Observatoire de la Côte d'Azur, CNRS, IRD, Géoazur, 250 Avenue Albert Einstein, F-06560 Valbonne, France
4 shared publicationsAgnès Levy
ONERA 29 avenue de la Division Leclerc F-92322 Châtillon France
3 shared publicationsAlain Robert
CNES, 18 avenue E Belin, F-31 401 Toulouse, France
3 shared publications
Latest Publications
- Open Access
- 7 September 2022
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 39 (20) , 204006
MICROSCOPE: systematic errors
The MICROSCOPE mission aims to test the weak equivalence principle (WEP) in orbit with an unprecedented precision of 10−15 on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Systematic error sources can be divided into three categories: external perturbations, such as the residual atmospheric drag or the gravity gradient at the satellite altitude, perturbations linked to the satellite design, such as thermal or magnetic perturbations, and perturbations from the instrument internal sources. Each systematic error is evaluated or bounded in order to set a reliable upper bound on the WEP parameter estimation uncertainty.
- 7 September 2022
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 39 (20) , 204006
Open AccessMICROSCOPE: systematic errors
The MICROSCOPE mission aims to test the weak equivalence principle (WEP) in orbit with an unprecedented precision of 10−15 on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Systematic error sources can be divided into three categories: external perturbations, such as the residual atmospheric drag or the gravity gradient at the satellite altitude, perturbations linked to the satellite design, such as thermal or magnetic perturbations, and perturbations from the instrument internal sources. Each systematic error is evaluated or bounded in order to set a reliable upper bound on the WEP parameter estimation uncertainty.
- Open Access
- 7 July 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (14) , 3273
Hybrid Electrostatic–Atomic Accelerometer for Future Space Gravity Missions
Long-term observation of Earth’s temporal gravity field with enhanced temporal and spatial resolution is a major objective for future satellite gravity missions. Improving the performance of the accelerometers present in such missions is one of the main paths to explore. In this context, we propose to study an original concept of a hybrid accelerometer associating a state-of-the-art electrostatic accelerometer (EA) and a promising quantum sensor based on cold atom interferometry. To assess the performance potential of such an instrument, numerical simulations were performed to determine its impact in terms of gravity field retrieval. Taking advantage of the long-term stability of the cold atom interferometer (CAI), it is shown that the reduced drift of the hybrid sensor could lead to improved gravity field retrieval. Nevertheless, this gain vanishes once temporal variations of the gravity field and related aliasing effects are taken into account. Improved de-aliasing models or some specific satellite constellations are then required to maximize the impact of the accelerometer performance gain. To evaluate the achievable acceleration performance in-orbit, a numerical simulator of the hybrid accelerometer was developed and preliminary results are given. The instrument simulator was in part validated by reproducing the performance achieved with a hybrid lab prototype operating on the ground. The problem of satellite rotation impact on the CAI was also investigated both with instrument performance simulations and experimental demonstrations. It is shown that the proposed configuration, where the EA’s proof-mass acts as the reference mirror for the CAI, seems a promising approach to allow the mitigation of satellite rotation. To evaluate the feasibility of such an instrument for space applications, a preliminary design is elaborated along with a preliminary error, mass, volume, and electrical power consumption budget.
- 7 July 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (14) , 3273
Open AccessHybrid Electrostatic–Atomic Accelerometer for Future Space Gravity Missions
Long-term observation of Earth’s temporal gravity field with enhanced temporal and spatial resolution is a major objective for future satellite gravity missions. Improving the performance of the accelerometers present in such missions is one of the main paths to explore. In this context, we propose to study an original concept of a hybrid accelerometer associating a state-of-the-art electrostatic accelerometer (EA) and a promising quantum sensor based on cold atom interferometry. To assess the performance potential of such an instrument, numerical simulations were performed to determine its impact in terms of gravity field retrieval. Taking advantage of the long-term stability of the cold atom interferometer (CAI), it is shown that the reduced drift of the hybrid sensor could lead to improved gravity field retrieval. Nevertheless, this gain vanishes once temporal variations of the gravity field and related aliasing effects are taken into account. Improved de-aliasing models or some specific satellite constellations are then required to maximize the impact of the accelerometer performance gain. To evaluate the achievable acceleration performance in-orbit, a numerical simulator of the hybrid accelerometer was developed and preliminary results are given. The instrument simulator was in part validated by reproducing the performance achieved with a hybrid lab prototype operating on the ground. The problem of satellite rotation impact on the CAI was also investigated both with instrument performance simulations and experimental demonstrations. It is shown that the proposed configuration, where the EA’s proof-mass acts as the reference mirror for the CAI, seems a promising approach to allow the mitigation of satellite rotation. To evaluate the feasibility of such an instrument for space applications, a preliminary design is elaborated along with a preliminary error, mass, volume, and electrical power consumption budget.
- Open Access
MICROSCOPE instrument in-flight characterization
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
Open AccessMICROSCOPE instrument in-flight characterization
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
- 1 May 2019
- Published by Elsevier in Advances In Space Research
- Vol. 63 (10) , 3235-3248
Impact of a novel hybrid accelerometer on satellite gravimetry performance
- 1 May 2019
- Published by Elsevier in Advances In Space Research
- Vol. 63 (10) , 3235-3248
Impact of a novel hybrid accelerometer on satellite gravimetry performance
- Top Cited Papers
- 4 December 2017
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 119 (23) , 231101
MICROSCOPE Mission: First Results of a Space Test of the Equivalence Principle
According to the weak equivalence principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A nonvanishing result would correspond to a violation of the equivalence principle, or to the discovery of a new long-range force. Analysis of the first data gives ( statistical uncertainty) for the titanium-platinum Eötvös parameter characterizing the relative difference in their free-fall accelerations.- 4 December 2017
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 119 (23) , 231101
Top Cited PapersMICROSCOPE Mission: First Results of a Space Test of the Equivalence Principle
According to the weak equivalence principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A nonvanishing result would correspond to a violation of the equivalence principle, or to the discovery of a new long-range force. Analysis of the first data gives ( statistical uncertainty) for the titanium-platinum Eötvös parameter characterizing the relative difference in their free-fall accelerations. - Open Access
Determination of the Equivalence Principle violation signal for the MICROSCOPE space mission: optimization of the signal processing
The MICROSCOPE space mission aims at testing the Equivalence Principle (EP) with an accuracy of $10^{-15}$. The test is based on the precise measurement delivered by a differential electrostatic accelerometer on-board a drag-free microsatellite which includes two cylindrical test masses submitted to the same gravitational field and made of different materials. The experiment consists in testing the equality of the electrostatic acceleration applied to the masses to maintain them relatively motionless at a well-known frequency. This high precision experiment is compatible with only very little perturbations. However, aliasing arises from the finite time span of the measurement, and is amplified by measurement losses. These effects perturb the measurement analysis. Numerical simulations have been run to estimate the contribution of a perturbation at any frequency on the EP violation frequency and to test its compatibility with the mission specifications. Moreover, different data analysis procedures have been considered to select the one minimizing these effects taking into account the uncertainty about the frequencies of the implicated signals.Open AccessDetermination of the Equivalence Principle violation signal for the MICROSCOPE space mission: optimization of the signal processing
The MICROSCOPE space mission aims at testing the Equivalence Principle (EP) with an accuracy of $10^{-15}$. The test is based on the precise measurement delivered by a differential electrostatic accelerometer on-board a drag-free microsatellite which includes two cylindrical test masses submitted to the same gravitational field and made of different materials. The experiment consists in testing the equality of the electrostatic acceleration applied to the masses to maintain them relatively motionless at a well-known frequency. This high precision experiment is compatible with only very little perturbations. However, aliasing arises from the finite time span of the measurement, and is amplified by measurement losses. These effects perturb the measurement analysis. Numerical simulations have been run to estimate the contribution of a perturbation at any frequency on the EP violation frequency and to test its compatibility with the mission specifications. Moreover, different data analysis procedures have been considered to select the one minimizing these effects taking into account the uncertainty about the frequencies of the implicated signals. - Open Access
Validation of the in-flight calibration procedures for the MICROSCOPE space mission
The MICROSCOPE space mission aims to test the Equivalence Principle with an accuracy of $10^{-15}$. The drag-free micro-satellite will orbit around the Earth and embark a differential electrostatic accelerometer including two cylindrical test masses submitted to the same gravitational field and made of different materials. The experience consists in testing the equality of the electrostatic acceleration applied to the masses to maintain them relatively motionless. The accuracy of the measurements exploited for the test of the Equivalence Principle is limited by our a priori knowledge of several physical parameters of the instrument. These parameters are partially estimated on-ground, but with an insufficient accuracy, and an in-orbit calibration is therefore required to correct the measurements. The calibration procedures have been defined and their analytical performances have been evaluated. In addition, a simulator software including the dynamics model of the instrument, the satellite drag-free system and the perturbing environment has been developed to numerically validate the analytical results. After an overall presentation of the MICROSCOPE mission, this paper will describe the calibration procedures and focus on the simulator. Such an in-flight calibration is mandatory for similar space missions taking advantage of a drag-free system.Open AccessValidation of the in-flight calibration procedures for the MICROSCOPE space mission
The MICROSCOPE space mission aims to test the Equivalence Principle with an accuracy of $10^{-15}$. The drag-free micro-satellite will orbit around the Earth and embark a differential electrostatic accelerometer including two cylindrical test masses submitted to the same gravitational field and made of different materials. The experience consists in testing the equality of the electrostatic acceleration applied to the masses to maintain them relatively motionless. The accuracy of the measurements exploited for the test of the Equivalence Principle is limited by our a priori knowledge of several physical parameters of the instrument. These parameters are partially estimated on-ground, but with an insufficient accuracy, and an in-orbit calibration is therefore required to correct the measurements. The calibration procedures have been defined and their analytical performances have been evaluated. In addition, a simulator software including the dynamics model of the instrument, the satellite drag-free system and the perturbing environment has been developed to numerically validate the analytical results. After an overall presentation of the MICROSCOPE mission, this paper will describe the calibration procedures and focus on the simulator. Such an in-flight calibration is mandatory for similar space missions taking advantage of a drag-free system. - 1 November 2013
- Published by Elsevier in Advances In Space Research
- Vol. 52 (9) , 1634-1646
Validation of the in-flight calibration procedures for the MICROSCOPE space mission
- 1 November 2013
- Published by Elsevier in Advances In Space Research
- Vol. 52 (9) , 1634-1646
Validation of the in-flight calibration procedures for the MICROSCOPE space mission
- 15 October 2013
- Published by Springer Nature in Space Science Reviews
- Vol. 180 (1-4) , 177-191
Determination of the Equivalence Principle Violation Signal for the MICROSCOPE Space Mission: Optimization of the Signal Processing
- 15 October 2013
- Published by Springer Nature in Space Science Reviews
- Vol. 180 (1-4) , 177-191
Determination of the Equivalence Principle Violation Signal for the MICROSCOPE Space Mission: Optimization of the Signal Processing