AMAlberto Maran

Alberto Maran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alberto Maran has a total of 154 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diabetic Ketoacidosis at Diagnosis is Associated With Adverse Long‐Term Glycaemic Trajectories and Retinopathy in Adult‐Onset Type 1 Diabetes. A Single‐Centre Retrospective Cohort Study

    by Riccardo Maria Pollis, Federico Boscari, Damiano Furlanetto, Cristina Bittante, Maria Cristina Crepaldi, Monica Vedovato, Daniela Bruttomesso, Alberto Maran, Benedetta Maria Bonora, Mario Luca Morieri, et al.

    Aims: The long‐term significance of diabetic ketoacidosis (DKA) at the diagnosis of adult‐onset type 1 diabetes (T1D) is poorly understood. We investigated the association between DKA at diagnosis and long‐term outcomes. Methods: In this retrospective study, we analysed adults with T1D diagnosed at age ≥ 18 years who attended a single tertiary diabetes centre between 2000 and 2025. Participants were classified according to the presence or absence of DKA at diagnosis. Longitudinal changes in HbA1c were analysed using mixed models. Incident chronic complications were evaluated using Cox regression models. Results: Among 517 adults with T1D (47.2% women), 112 (21.7%) presented with DKA at diagnosis. The frequency of DKA at diagnosis increased from 13.2% in 2000–2008 to 34.6% after 2016 ( p < 0.001). During a median (IQR) follow‐up of 9.3 (3.5–15.5) years after cohort entry, individuals presenting with DKA had persistently higher HbA1c levels than those without DKA, with an adjusted between‐group difference of 0.37% (95% CI 0.20, 0.53; p < 0.001). When data were aligned to the diabetes onset date, the estimated mean difference was 0.66% ( p < 0.001). In exploratory analyses, DKA at diagnosis was associated with a higher incidence of retinopathy (HR 1.61; 95% CI 1.02–2.55; p = 0.041). The association was confirmed after accounting for delayed cohort entry and was attenuated by adjusting for mean HbA1c during follow‐up. Conclusions: Among individuals with adult‐onset T1D attending a tertiary diabetes clinic, DKA at diagnosis was associated with persistently less favourable glycaemic control during long‐term follow‐up. Interpretation is limited by the single‐centre retrospective design and delayed cohort entry.

  • The Diabetes Technology Society Error Grid and Trend Accuracy Matrix for Glucose Monitors

    by David C. Klonoff, Guido Freckmann, Stefan Pleus, Boris P. Kovatchev, David Kerr, Chui (Cindy) Tse, Chengdong Li, Michael S. D. Agus, Kathleen Dungan, Barbora Voglová Hagerf, et al.

    Introduction: An error grid compares measured versus reference glucose concentrations to assign clinical risk values to observed errors. Widely used error grids for blood glucose monitors (BGMs) have limited value because they do not also reflect clinical accuracy of continuous glucose monitors (CGMs). Methods: Diabetes Technology Society (DTS) convened 89 international experts in glucose monitoring to (1) smooth the borders of the Surveillance Error Grid (SEG) zones and create a user-friendly tool—the DTS Error Grid; (2) define five risk zones of clinical point accuracy (A-E) to be identical for BGMs and CGMs; (3) determine a relationship between DTS Error Grid percent in Zone A and mean absolute relative difference (MARD) from analyzing 22 BGM and nine CGM accuracy studies; and (4) create trend risk categories (1-5) for CGM trend accuracy. Results: The DTS Error Grid for point accuracy contains five risk zones (A-E) with straight-line borders that can be applied to both BGM and CGM accuracy data. In a data set combining point accuracy data from 18 BGMs, 2.6% of total data pairs equally moved from Zones A to B and vice versa (SEG compared with DTS Error Grid). For every 1% increase in percent data in Zone A, the MARD decreased by approximately 0.33%. We also created a DTS Trend Accuracy Matrix with five trend risk categories (1-5) for CGM-reported trend indicators compared with reference trends calculated from reference glucose. Conclusion: The DTS Error Grid combines contemporary clinician input regarding clinical point accuracy for BGMs and CGMs. The DTS Trend Accuracy Matrix assesses accuracy of CGM trend indicators.


  • Glycaemic variability-based classification of impaired glucose tolerance vs. type 2 diabetes using continuous glucose monitoring data

    by Enrico Longato, Giada Acciaroli, Andrea Facchinetti, Liisa Hakaste, Tiinamaija Tuomi, Alberto Maran, Giovanni Sparacino


  • Cognitive, neurophysiologic and metabolic sequelae of previous hypoglycemic coma revealed by hyperinsulinemic-hypoglycemic clamp in type 1 diabetic patients

    by Alberto Maran, Cristina Crepaldi, Franco Del Piccolo, Ian Macdonald, Lisa Zarantonello, Angelo Avogaro, Piero Amodio

    To examine the relationship between electroencephalographic (EEG) activity and hypoglycemia unawareness, we investigated early parameters of vigilance and awareness of various symptom categories in response to hypoglycemia in intensively treated type 1 diabetic (T1DM) patients with different degrees of hypoglycemia unawareness. Hypoglycemia was induced with a hyperinsulinemic-hypoglycemic clamp in six T1DM patients with a history of hypoglycemia unawareness previous severe hypoglycemic coma (SH) and in six T1DM patients without (C) history of hypoglycemia unawareness previous severe hypoglycemic coma. Cognitive function tests (four choice reaction time), counterregulatory responses (adrenaline), and symptomatic responses were evaluated at euglycemia (90 mg/dl) and during step-wise plasma glucose reduction (68, 58 and 49 mg/dl). EEG activity was recorded continuously throughout the study and analyzed by spectral analysis. Cognitive function deteriorated significantly at a glucose threshold of 55 ± 1 mg/dl in both groups (p = ns) during hypoglycemia, while the glucose threshold for autonomic symptoms was significantly lower in SH patients than in C patients (49 ± 1 vs. 54 ± 1 mg/dl, p < 0.05, respectively). In SH patients, eye-closed resting EEG showed a correlation between the mean dominance frequency and plasma glucose (r = 0.62, p < 0.001). Theta relative power increased during controlled hypoglycemia compared to euglycemia (21.6 ± 6 vs. 15.5 ± 3% Hz p < 0.05) and was higher than in the C group (21.6 ± 6 vs. 13.8 ± 3%, p < 0.03). The cognitive task beta activity was lower in the SH group than in the C group (14.8 ± 3 Hz, vs. 22.6 ± 4 vs. p < 0.03). Controlled hypoglycemia elicits cognitive dysfunction in both C and SH patients; however, significant EEG alterations during hypoglycemia were detected mainly in patients with a history of hypoglycemia unawareness and previous severe hypoglycemic coma. These data suggest that prior episodes of hypoglycemic coma modulate brain electric activity.


  • Open Access

    Italian Contributions to the Development of Continuous Glucose Monitoring Sensors for Diabetes Management

    by Giovanni Sparacino, Mattia Zanon, Andrea Facchinetti, Chiara Zecchin, Alberto Maran, Claudio Cobelli

    Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy), causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy). In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate) for relatively long intervals (up to 7 consecutive days). These continuous glucose monitoring (CGM) sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community.


  • Open Access

    Closed-Loop Artificial Pancreas Using Subcutaneous Glucose Sensing and Insulin Delivery and a Model Predictive Control Algorithm: Preliminary Studies in Padova and Montpellier

    by Daniela Bruttomesso, Anne Farret, Silvana Costa, Maria Cristina Marescotti, Monica Vettore, Angelo Avogaro, Antonio Tiengo, Chiara Dalla Man, Jerome Place, Andrea Facchinetti, et al.

    New effort has been made to develop closed-loop glucose control, using subcutaneous (SC) glucose sensing and continuous subcutaneous insulin infusion (CSII) from a pump, and a control algorithm. An approach based on a model predictive control (MPC) algorithm has been utilized during closed-loop control in type 1 diabetes patients. Here we describe the preliminary clinical experience with this approach. In Padova, two out of three subjects showed better performance with the closed-loop system compared to open loop. Altogether, mean overnight plasma glucose (PG) levels were 134 versus 111 mg/dl during open loop versus closed loop, respectively. The percentage of time spent at PG > 140 mg/dl was 45% versus 12%, while postbreakfast mean PG was 165 versus 156 mg/dl during open loop versus closed loop, respectively. Also, in Montpellier, two patients out of three showed a better glucose control during closed-loop trials. Avoidance of nocturnal hypoglycemic excursions was a clear benefit during algorithm-guided insulin delivery in all cases. This preliminary set of studies demonstrates that closed-loop control based entirely on SC glucose sensing and insulin delivery is feasible and can be applied to improve glucose control in patients with type 1 diabetes, although the algorithm needs to be further improved to achieve better glycemic control. Six type 1 diabetes patients (three in each of two clinical investigation centers in Padova and Montpellier), using CSII, aged 36 ± 8 and 48 ± 6 years, duration of diabetes 12 ± 8 and 29 ± 4 years, hemoglobin A1c 7.4% ± 0.1% and 7.3% ± 0.3%, body mass index 23.2 ± 0.3 and 28.4 ± 2.2 kg/m2, respectively, were studied on two occasions during 22 h overnight hospital admissions 2–4 weeks apart. A Freestyle Navigator® continuous glucose monitor and an OmniPod® insulin pump were applied in each trial. Admission 1 used open-loop control, while admission 2 employed closed-loop control using our MPC algorithm.


  • Continuous glucose monitoring in conditions other than diabetes

    by Alberto Maran, Cristina Crepaldi, Angelo Avogaro, Susanna Catuogno, Alberto Burlina, Alessandro Poscia, Antonio Tiengo

    Background The development of new systems for continuous glucose monitoring has recently increased the interest for their potential applications among physicians involved in diabetes care. One of the most common applications of such devices is the identification of hypoglycaemic events in insulin‐treated diabetic patients (particularly during the night) and the evaluation of the full daily glucose excursions. Methods Among commercially available glucose sensors, the Glucoday® system has been utilized for practical clinical application in the last two years. One of the most important features of this device is the accuracy in monitoring interstitial glucose values, specifically in the hypoglycaemic range. This feature is clinically relevant when applied in the clinical setting of patients with type 1 diabetes mellitus. The ability to monitor glucose continuously could be indeed a useful tool for the study of hypoglycaemic conditions other than diabetes. Results In patients with hyperinsulinaemic hypoglycaemia, recurrent episodes of asymptomatic hypoglycaemia are common, and in patients with glycogen storage diseases, avoidance of recurrent and prolonged hypoglycaemic episodes usually require frequent determinations by mean of home blood glucose monitoring. Conclusions Experimental preliminary evidences suggest that this new technology could be applied in the clinical setting to help the physician to identify mainly nocturnal hypoglycaemic events, otherwise not revealed by traditional self blood‐glucose monitoring, even in those patients who are not treated by conventional insulin therapy. Copyright © 2004 John Wiley & Sons, Ltd.


    • 1 December 2002
      • Vol. 15  (6) , 429-433

    Continuous subcutaneous glucose monitoring: The GlucoDay® system

    by A Maran, A Poscia


  • Open Access

    Continuous Subcutaneous Glucose Monitoring in Diabetic Patients

    by Alberto Maran, Cristina Crepaldi, Antonio Tiengo, Giorgio Grassi, Emanuela Vitali, Gianfranco Pagano, Sergio Bistoni, Giuseppe Calabrese, Fausto Santeusanio, Frida Leonetti, et al.

    OBJECTIVE—To evaluate the accuracy of a new subcutaneous glucose sensor (Glucoday; A. Menarini Diagnostics) compared with venous blood glucose measurement in type 1 and type 2 diabetic patients. RESEARCH DESIGN—A multicenter study was performed in 70 diabetic patients. A microdialysis fiber was inserted subcutaneously into the periumbelical region and perfused with a buffer solution. Glucose concentrations in the dialysate were then measured every 3 min by the glucose sensor over a 24-h period, during which nine venous blood samples were also collected throughout the day. RESULTS—Both the insertion of the fiber and the wearing of the device were well tolerated by the patients. Subcutaneous glucose levels were well correlated with venous glucose measurements (r = 0.9, P < 0.001) over a wide range (40–400 mg/dl) for up to 24 h, with a single-point calibration. An analysis of 381 data pairs showed a linear relationship between the GlucoDay and serial venous blood glucose levels, and 97% of the data fell in the A and B regions of the error grid analysis. Percentage bias between the GlucoDay and the blood venous levels was −2.0% in the hypoglycemic range (180 mg/dl). CONCLUSIONS—The GlucoDay system demonstrated high reliability and reported values that closely agreed with venous blood glucose measurements. The system was well tolerated and thus constitutes a relatively easy method to monitor glucose excursions in diabetic patients.