Pedro Orival Luccas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedro Orival Luccas has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Célio Wisniewski
Department of Physics, Federal University of Alfenas, 37130-000 Alfenas, MG, Brazil
7 shared publications- Ayla Campos Do Lago
Institute of Chemistry, Federal University of Alfenas, 37130-000 Alfenas, MG, Brazil; Laboratory of Toxicant and Drug Analyses, Federal University of Alfenas, 37130-000 Alfenas, MG, Brazil
5 shared publications - Camila Marchioni
Department of Pathology, Federal University of Santa Catarina, St. Delfino Conti S/N, Florianopolis, SC, 88040-370, Brazil.
3 shared publications Pedro Marcos Frugeri
Institute of Chemistry, Federal University of Alfenas, 37130-000 Alfenas, MG, Brazil
3 shared publicationsFagner Moreira de Oliveira
Institute of Chemistry, Federal University of Alfenas, Alfenas, Minas Gerais, Brazil
2 shared publicationsCesar Ricardo Teixeira Tarley
Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, 445, Km 380, Londrina, 86057-970, PR, Brazil
1 shared publication
Latest Publications
- 17 December 2024
- Published by Springer Nature in Food Analytical Methods
- Vol. 18 (4) , 542-551
The Use of Carbon Fiber Restricted Access Material for Cadmium Determination in Milk Whey
- 17 December 2024
- Published by Springer Nature in Food Analytical Methods
- Vol. 18 (4) , 542-551
The Use of Carbon Fiber Restricted Access Material for Cadmium Determination in Milk Whey
- 19 March 2018
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (10) , 1492-1504
Determination of Sulfaguanidine in Food and Veterinary Pharmaceuticals by Flow Injection Analysis with Spectrophotometric Detection
This work proposes a flow injection analysis system for sulfaguanidine determination in pharmaceutical and food samples. The method was based on the reaction of sulfaguanidine with nitronium ion to produce a colored complex whose absorbance was measured at 545 nm. The flow injection analysis system’s significant parameters were checked by a fractional factorial design 27–2 and optimization by a Doehlert matrix. The flow injection analysis system shows optimum values at 0.28, 2.00, and 0.11% (w/v) for N-naphtil ethylenediamine, ammonium sulfamate, and sodium nitrite concentrations, respectively. The possible interferents present in pharmaceutical and food samples were assessed by a multivariate technique and depicted on probability charts, indicating no significant interferences at the 95% level of confidence interval. The method showed detection and quantification limits of 0.012 and 0.039 mg L−1, an analytical frequency of 30 readings h−1 and precision always lower than 5.0% expressed as the relative standard deviation. The obtained results were in accordance with those obtained by high-performance liquid chromatography.
- 19 March 2018
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (10) , 1492-1504
Determination of Sulfaguanidine in Food and Veterinary Pharmaceuticals by Flow Injection Analysis with Spectrophotometric Detection
This work proposes a flow injection analysis system for sulfaguanidine determination in pharmaceutical and food samples. The method was based on the reaction of sulfaguanidine with nitronium ion to produce a colored complex whose absorbance was measured at 545 nm. The flow injection analysis system’s significant parameters were checked by a fractional factorial design 27–2 and optimization by a Doehlert matrix. The flow injection analysis system shows optimum values at 0.28, 2.00, and 0.11% (w/v) for N-naphtil ethylenediamine, ammonium sulfamate, and sodium nitrite concentrations, respectively. The possible interferents present in pharmaceutical and food samples were assessed by a multivariate technique and depicted on probability charts, indicating no significant interferences at the 95% level of confidence interval. The method showed detection and quantification limits of 0.012 and 0.039 mg L−1, an analytical frequency of 30 readings h−1 and precision always lower than 5.0% expressed as the relative standard deviation. The obtained results were in accordance with those obtained by high-performance liquid chromatography.
- 28 July 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (11) , 1842-1850
Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry
This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L −1 and buffer concentration of 0.01 mol L −1 , were adopted. The proposed method showed a linear response in the range of 0.081–10.0 μg L −1 , limits detection and quantification of 0.024 and 0.081 μg L −1 , respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min −1 , and frequency of readings equal to 26 readings h −1 . The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg −1 ), black tea (1.09 ± 0.15 μg kg −1 ), green tea (3.85 ± 0.13 μg kg −1 ), cigarette tobacco (38.27 ± 0.22 μg kg −1 ), and hair (0.35 ± 0.02 μg kg −1 ).
- 28 July 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (11) , 1842-1850
Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry
This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L −1 and buffer concentration of 0.01 mol L −1 , were adopted. The proposed method showed a linear response in the range of 0.081–10.0 μg L −1 , limits detection and quantification of 0.024 and 0.081 μg L −1 , respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min −1 , and frequency of readings equal to 26 readings h −1 . The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg −1 ), black tea (1.09 ± 0.15 μg kg −1 ), green tea (3.85 ± 0.13 μg kg −1 ), cigarette tobacco (38.27 ± 0.22 μg kg −1 ), and hair (0.35 ± 0.02 μg kg −1 ).
- 24 May 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (2) , 414-430
Digital Image Analysis for the Colorimetric Determination of Aluminum, Total Iron, Nitrite and Soluble Phosphorus in Waters
A webcam was used to determine Al(III), total Fe, , and in waters by digital image colorimetry. Least squares regression was used to obtain a quadratic equation based on the red, green, blue, hue, saturation, and brightness color values, which allowed the evaluation of the wavelength of maximum absorption of the analytes. To determine the concentrations, the red, green, and blue intensities were converted into absorbances. For Al(III) and determination, the best results were attained when the absorbances relative to the green color were used. For total Fe and determination, the combined absorbances of green and blue and red and blue color led to higher sensitivity (slope) and coefficients of determination. The limits of detection for Al(III), total Fe, , and determinations were 2.59 × 10−7, 3.58 × 10−7, 1.09 × 10−7, and 1.65 × 10−7 mol L−1, respectively. The values for total Fe, , and were lower than comparative spectrophotometric techniques. The limits of detection were compatible with the Brazilian legislation for potable water. The developed procedure was successfully used for the determination of the wavelength of maximum absorption and the concentration of the analytes in water and wastewater. The reported procedure is simple, versatile, and low cost and demonstrates that a webcam is a suitable detector for determining Al(III), total Fe, , and in water with adequate accuracy and precision.
- 24 May 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (2) , 414-430
Digital Image Analysis for the Colorimetric Determination of Aluminum, Total Iron, Nitrite and Soluble Phosphorus in Waters
A webcam was used to determine Al(III), total Fe, , and in waters by digital image colorimetry. Least squares regression was used to obtain a quadratic equation based on the red, green, blue, hue, saturation, and brightness color values, which allowed the evaluation of the wavelength of maximum absorption of the analytes. To determine the concentrations, the red, green, and blue intensities were converted into absorbances. For Al(III) and determination, the best results were attained when the absorbances relative to the green color were used. For total Fe and determination, the combined absorbances of green and blue and red and blue color led to higher sensitivity (slope) and coefficients of determination. The limits of detection for Al(III), total Fe, , and determinations were 2.59 × 10−7, 3.58 × 10−7, 1.09 × 10−7, and 1.65 × 10−7 mol L−1, respectively. The values for total Fe, , and were lower than comparative spectrophotometric techniques. The limits of detection were compatible with the Brazilian legislation for potable water. The developed procedure was successfully used for the determination of the wavelength of maximum absorption and the concentration of the analytes in water and wastewater. The reported procedure is simple, versatile, and low cost and demonstrates that a webcam is a suitable detector for determining Al(III), total Fe, , and in water with adequate accuracy and precision.
- Open Access
- 1 January 2015
- Published by Universidade Vale do Rio Verde (UninCor) in Revista da Universidade Vale do Rio Verde
- Vol. 13 (2) , 19-37
DINÂMICA DOS COMPOSTOS DE ENXOFRE EM UMA REPRESA DA ZONA RURAL DE MONTE BELO, MINAS GERAIS, BRASIL
Foram feitas determinações de sulfato e sulfeto em amostras de água de uma represa localizada na Fazenda Lagoa, Instituto Sul-mineiro de Proteção Ambiental, Monte Belo, Minas Gerais. A concentração média de sulfato foi 13,47 ppm. Obtiveram-se concentrações para sulfeto de 5,5 a14,3 ppb. Nota-se estratificação da coluna d’água na represa e correlação entre os teores de compostos de enxofre, parâmetros físico-químicos e teores de ferro e alumínio. Variações sazonais típicas do ecossistema foram observadas. Os processos de oxirredução constituem importantes mecanismos de reciclagem do enxofre na represa, postulando-se que sejam típicos desse ambiente, i.é., lagoa mesotrófica.
- 1 January 2015
- Published by Universidade Vale do Rio Verde (UninCor) in Revista da Universidade Vale do Rio Verde
- Vol. 13 (2) , 19-37
Open AccessDINÂMICA DOS COMPOSTOS DE ENXOFRE EM UMA REPRESA DA ZONA RURAL DE MONTE BELO, MINAS GERAIS, BRASIL
Foram feitas determinações de sulfato e sulfeto em amostras de água de uma represa localizada na Fazenda Lagoa, Instituto Sul-mineiro de Proteção Ambiental, Monte Belo, Minas Gerais. A concentração média de sulfato foi 13,47 ppm. Obtiveram-se concentrações para sulfeto de 5,5 a14,3 ppb. Nota-se estratificação da coluna d’água na represa e correlação entre os teores de compostos de enxofre, parâmetros físico-químicos e teores de ferro e alumínio. Variações sazonais típicas do ecossistema foram observadas. Os processos de oxirredução constituem importantes mecanismos de reciclagem do enxofre na represa, postulando-se que sejam típicos desse ambiente, i.é., lagoa mesotrófica.
- 1 January 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 809, 82-87
Assessment of cadmium and iron adsorption in sediment, employing a flow injection analysis system with on line filtration and detection by flame atomic absorption spectrometry and thermospray flame furnace atomic absorption spectrometry
- 1 January 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 809, 82-87
Assessment of cadmium and iron adsorption in sediment, employing a flow injection analysis system with on line filtration and detection by flame atomic absorption spectrometry and thermospray flame furnace atomic absorption spectrometry
- 1 January 2014
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 117, 304-308
A spectrophotometric flow injection system for streptomycin determination in veterinary samples
- 1 January 2014
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 117, 304-308
A spectrophotometric flow injection system for streptomycin determination in veterinary samples