Ayla Campos Do Lago
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ayla Campos Do Lago has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Célio Wisniewski
Department of Physics, Federal University of Alfenas, 37130-000 Alfenas, MG, Brazil
5 shared publications- Pedro Orival Luccas
Chemistry Institute, Federal University of Alfenas, Alfenas, Brazil
5 shared publications - Camila Marchioni
Department of Pathology, Federal University of Santa Catarina, St. Delfino Conti S/N, Florianopolis, SC, 88040-370, Brazil.
3 shared publications Pedro Marcos Frugeri
Institute of Chemistry, Federal University of Alfenas, 37130-000 Alfenas, MG, Brazil
3 shared publications- Pedro Sergio Fadini
Universidade Federal de São Carlos
3 shared publications - Eduardo Costa Figueiredo
Laboratory of Toxics and Drug Analysis, Faculty of Pharmaceutical Sciences, Universidade Federal de Alfenas, 37130-001 Alfenas, MG, Brazil
2 shared publications
Latest Publications
- 1 March 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1102, 11-23
Magnetic restricted-access carbon nanotubes for dispersive solid phase extraction of organophosphates pesticides from bovine milk samples
- 1 March 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1102, 11-23
Magnetic restricted-access carbon nanotubes for dispersive solid phase extraction of organophosphates pesticides from bovine milk samples
- Open Access
- 20 September 2019
- Published by Springer Nature in SN Applied Sciences
- Vol. 1 (10) , 1-12
Magnetic restricted access carbon nanotubes for smooth Cu and Zn extraction from Cu, Zn-superoxide dismutase
- 20 September 2019
- Published by Springer Nature in SN Applied Sciences
- Vol. 1 (10) , 1-12
Open AccessMagnetic restricted access carbon nanotubes for smooth Cu and Zn extraction from Cu, Zn-superoxide dismutase
- 19 March 2018
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (10) , 1492-1504
Determination of Sulfaguanidine in Food and Veterinary Pharmaceuticals by Flow Injection Analysis with Spectrophotometric Detection
This work proposes a flow injection analysis system for sulfaguanidine determination in pharmaceutical and food samples. The method was based on the reaction of sulfaguanidine with nitronium ion to produce a colored complex whose absorbance was measured at 545 nm. The flow injection analysis system’s significant parameters were checked by a fractional factorial design 27–2 and optimization by a Doehlert matrix. The flow injection analysis system shows optimum values at 0.28, 2.00, and 0.11% (w/v) for N-naphtil ethylenediamine, ammonium sulfamate, and sodium nitrite concentrations, respectively. The possible interferents present in pharmaceutical and food samples were assessed by a multivariate technique and depicted on probability charts, indicating no significant interferences at the 95% level of confidence interval. The method showed detection and quantification limits of 0.012 and 0.039 mg L−1, an analytical frequency of 30 readings h−1 and precision always lower than 5.0% expressed as the relative standard deviation. The obtained results were in accordance with those obtained by high-performance liquid chromatography.
- 19 March 2018
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (10) , 1492-1504
Determination of Sulfaguanidine in Food and Veterinary Pharmaceuticals by Flow Injection Analysis with Spectrophotometric Detection
This work proposes a flow injection analysis system for sulfaguanidine determination in pharmaceutical and food samples. The method was based on the reaction of sulfaguanidine with nitronium ion to produce a colored complex whose absorbance was measured at 545 nm. The flow injection analysis system’s significant parameters were checked by a fractional factorial design 27–2 and optimization by a Doehlert matrix. The flow injection analysis system shows optimum values at 0.28, 2.00, and 0.11% (w/v) for N-naphtil ethylenediamine, ammonium sulfamate, and sodium nitrite concentrations, respectively. The possible interferents present in pharmaceutical and food samples were assessed by a multivariate technique and depicted on probability charts, indicating no significant interferences at the 95% level of confidence interval. The method showed detection and quantification limits of 0.012 and 0.039 mg L−1, an analytical frequency of 30 readings h−1 and precision always lower than 5.0% expressed as the relative standard deviation. The obtained results were in accordance with those obtained by high-performance liquid chromatography.
- 28 July 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (11) , 1842-1850
Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry
This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L −1 and buffer concentration of 0.01 mol L −1 , were adopted. The proposed method showed a linear response in the range of 0.081–10.0 μg L −1 , limits detection and quantification of 0.024 and 0.081 μg L −1 , respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min −1 , and frequency of readings equal to 26 readings h −1 . The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg −1 ), black tea (1.09 ± 0.15 μg kg −1 ), green tea (3.85 ± 0.13 μg kg −1 ), cigarette tobacco (38.27 ± 0.22 μg kg −1 ), and hair (0.35 ± 0.02 μg kg −1 ).
- 28 July 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (11) , 1842-1850
Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry
This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L −1 and buffer concentration of 0.01 mol L −1 , were adopted. The proposed method showed a linear response in the range of 0.081–10.0 μg L −1 , limits detection and quantification of 0.024 and 0.081 μg L −1 , respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min −1 , and frequency of readings equal to 26 readings h −1 . The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg −1 ), black tea (1.09 ± 0.15 μg kg −1 ), green tea (3.85 ± 0.13 μg kg −1 ), cigarette tobacco (38.27 ± 0.22 μg kg −1 ), and hair (0.35 ± 0.02 μg kg −1 ).
- 15 June 2015
- Published by Taylor & Francis in Analytical Letters
- Vol. 48 (17) , 2739-2753
Determination of Uranium in Environmental Water by Flow Injection Analysis using a Hybrid-Imprinted Polymer
- 15 June 2015
- Published by Taylor & Francis in Analytical Letters
- Vol. 48 (17) , 2739-2753
Determination of Uranium in Environmental Water by Flow Injection Analysis using a Hybrid-Imprinted Polymer
- 1 January 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 809, 82-87
Assessment of cadmium and iron adsorption in sediment, employing a flow injection analysis system with on line filtration and detection by flame atomic absorption spectrometry and thermospray flame furnace atomic absorption spectrometry
- 1 January 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 809, 82-87
Assessment of cadmium and iron adsorption in sediment, employing a flow injection analysis system with on line filtration and detection by flame atomic absorption spectrometry and thermospray flame furnace atomic absorption spectrometry
- 1 January 2014
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 117, 304-308
A spectrophotometric flow injection system for streptomycin determination in veterinary samples
- 1 January 2014
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 117, 304-308
A spectrophotometric flow injection system for streptomycin determination in veterinary samples
- 1 March 2013
- Published by Elsevier in Analytica Chimica Acta
- Vol. 768, 35-40
Determination of selenium using atomically imprinted polymer (AIP) and hydride generation atomic absorption spectrometry
- 1 March 2013
- Published by Elsevier in Analytica Chimica Acta
- Vol. 768, 35-40
Determination of selenium using atomically imprinted polymer (AIP) and hydride generation atomic absorption spectrometry
- 15 June 2012
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 92 (7) , 767-782
Highly sensitive ion preconcentration method based on flow sorbent extraction using multiwall carbon nanotubes
In this work a solid phase on-line uranium ion preconcentration system coupled with spectrophotometry has been developed. The method is based on uranyl ion preconcentration at pH 3.75 onto multiwall carbon nanotubes treated with HNO3. After preconcentration, the uranyl ions are eluted with 0.32 mol L−1HCl followed by reaction with 3,6-bis[(2-arsonophenyl)-azo]-4,5-dihydroxy-2,7-naphthalendisulfonic acid 0.08%[w/v] (Arsenazo III), which had maximum monitored absorbance of 650 nm. Effects of the pertinent experimental parameters on the system were investigated by means of 26−2 fractional factorial design, while optimization was carried out using the Doehlert matrix. Under optimized conditions, detection and quantification limits were found to be 0.21 and 0.7 µg L−1, respectively. The analytical curve ranged from 5 to 150 µg L−1 (r = 0.998), while the relative standard deviations (RSD) were 3.27 and 2.56% for the respective uranium concentrations of 10 and 100 µg L−1 (n = 10). The features obtained for the on-line preconcentration system were: preconcentration factor of 228, concentration efficiency of 57 min−1, consumption index of 0.13 mL and sample throughput of 15 h−1. In order to assess the accuracy of the proposed method, addition and recovery studies were carried out on spring water samples from different sources and synthetic seawater with satisfactory results ranging from 94.85 up to 103.65%.
- 15 June 2012
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 92 (7) , 767-782
Highly sensitive ion preconcentration method based on flow sorbent extraction using multiwall carbon nanotubes
In this work a solid phase on-line uranium ion preconcentration system coupled with spectrophotometry has been developed. The method is based on uranyl ion preconcentration at pH 3.75 onto multiwall carbon nanotubes treated with HNO3. After preconcentration, the uranyl ions are eluted with 0.32 mol L−1HCl followed by reaction with 3,6-bis[(2-arsonophenyl)-azo]-4,5-dihydroxy-2,7-naphthalendisulfonic acid 0.08%[w/v] (Arsenazo III), which had maximum monitored absorbance of 650 nm. Effects of the pertinent experimental parameters on the system were investigated by means of 26−2 fractional factorial design, while optimization was carried out using the Doehlert matrix. Under optimized conditions, detection and quantification limits were found to be 0.21 and 0.7 µg L−1, respectively. The analytical curve ranged from 5 to 150 µg L−1 (r = 0.998), while the relative standard deviations (RSD) were 3.27 and 2.56% for the respective uranium concentrations of 10 and 100 µg L−1 (n = 10). The features obtained for the on-line preconcentration system were: preconcentration factor of 228, concentration efficiency of 57 min−1, consumption index of 0.13 mL and sample throughput of 15 h−1. In order to assess the accuracy of the proposed method, addition and recovery studies were carried out on spring water samples from different sources and synthetic seawater with satisfactory results ranging from 94.85 up to 103.65%.