Mingzhi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mingzhi Zhao has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Chun Chang
College of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, China
6 shared publications - Daorina Bao
School of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010010, China
4 shared publications - Ningbo Wang
School of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, China
4 shared publications - Bakhramzhan Rasakhodzhaev
National Research Institute of Renewable Energy Sources, Ministry of Energy of Uzbekistan, Tashkent 100084, Uzbekistan
3 shared publications - Rong Yu
College of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, China
3 shared publications Xiaobo Kang
School of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot, China 010051
3 shared publications
Latest Publications
- 5 October 2026
- Published by Springer Nature in Journal of Thermal Science
- Vol. 35 (6) , 2618-2638
Thermoelectric and Exergy Output Attenuation and Recovery of a Fresnel-Lens HCPV/T System under Natural Soiling and Compressed-Air Cleaning
- 5 October 2026
- Published by Springer Nature in Journal of Thermal Science
- Vol. 35 (6) , 2618-2638
Thermoelectric and Exergy Output Attenuation and Recovery of a Fresnel-Lens HCPV/T System under Natural Soiling and Compressed-Air Cleaning
- Open Access
Thermal and Electrical Performance of a Cascade PV/T Solar Drying System and Drying Kinetics of Carrot Slices
Solar hot-air drying technology has developed rapidly in the field of low-temperature fruit and vegetable processing; however, fluctuations in solar irradiance affect the stability of system energy supply and energy utilization efficiency. In this study, a cascaded photovoltaic/thermal (PV/T) solar drying system was constructed, and drying experiments were conducted on slices of the “Hohhot Hongying No. 2” carrot cultivar at 40, 45, 50, 55, and 60 °C. A hierarchical normalization method was employed to reduce the effects of meteorological differences among the experimental days, and the thermal performance, energy consumption, and drying kinetic characteristics of the material were analyzed. The results showed that the quasi-steady-state thermal efficiency of the system ranged from 29.7% to 38.3%. At 50 °C, the electrical energy consumption per unit mass of water removed was the lowest, at 0.430 kWh/kg. The effective moisture diffusivity calculated based on Fick’s second law increased from 8.99 × 10−9 to 1.98 × 10−8 m2/s with increasing drying temperature, and the coefficients of determination under all operating conditions were greater than 0.9906. Arrhenius fitting yielded a pre-exponential factor of 4.37 × 10−3 m2/s and an activation energy of 34.09 kJ/mol. Under the present experimental conditions, 50 °C exhibited a relatively favorable balance between energy consumption and drying rate within the investigated temperature range. These findings may provide a reference for selecting the operating parameters of small-scale PV/T solar drying systems. Nevertheless, further repeated experiments and product-quality assessments are required to verify the broader applicability of the results.
Open AccessThermal and Electrical Performance of a Cascade PV/T Solar Drying System and Drying Kinetics of Carrot Slices
Solar hot-air drying technology has developed rapidly in the field of low-temperature fruit and vegetable processing; however, fluctuations in solar irradiance affect the stability of system energy supply and energy utilization efficiency. In this study, a cascaded photovoltaic/thermal (PV/T) solar drying system was constructed, and drying experiments were conducted on slices of the “Hohhot Hongying No. 2” carrot cultivar at 40, 45, 50, 55, and 60 °C. A hierarchical normalization method was employed to reduce the effects of meteorological differences among the experimental days, and the thermal performance, energy consumption, and drying kinetic characteristics of the material were analyzed. The results showed that the quasi-steady-state thermal efficiency of the system ranged from 29.7% to 38.3%. At 50 °C, the electrical energy consumption per unit mass of water removed was the lowest, at 0.430 kWh/kg. The effective moisture diffusivity calculated based on Fick’s second law increased from 8.99 × 10−9 to 1.98 × 10−8 m2/s with increasing drying temperature, and the coefficients of determination under all operating conditions were greater than 0.9906. Arrhenius fitting yielded a pre-exponential factor of 4.37 × 10−3 m2/s and an activation energy of 34.09 kJ/mol. Under the present experimental conditions, 50 °C exhibited a relatively favorable balance between energy consumption and drying rate within the investigated temperature range. These findings may provide a reference for selecting the operating parameters of small-scale PV/T solar drying systems. Nevertheless, further repeated experiments and product-quality assessments are required to verify the broader applicability of the results.
- Open Access
- 22 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8359
Natural-Soiling Effects and Multi-Horizon Thermoelectric Forecasting of a Fresnel HCPV/T System in a Sandy Environment
Fresnel high-concentration photovoltaic/thermal (HCPV/T) systems operating in sandy environments are susceptible to natural lens soiling, which attenuates the effective concentrated solar input and alters electrical and thermal performance. Natural-soiling comparison tests were conducted over 0–28 d, and an SD-CNN-BiLSTM-Attention model was developed to forecast cell-center temperature and electrical power 5, 10, and 20 min ahead. At a surface soiling density of 10.760 g·m−2, current and electrical power decreased by 38.37% and 39.28%, respectively, relative to the concurrently operated clean-reference unit; cell-center temperature and water-tank temperature rise decreased by 7.74% and 15.13%. Thermal power also showed an overall downward trend, although the magnitude was affected by relatively large measurement uncertainty. Under grouped cross-validation, temperature RMSEs were 0.473, 0.515, and 0.555 °C at 5, 10, and 20 min, corresponding to reductions of 8.34%, 21.68%, and 44.07% relative to Persistence. Electrical-power RMSEs were 0.661, 0.618, and 0.640 W, with an 18.24% reduction relative to Persistence at 20 min. Ablation analysis showed a limited contribution from surface soiling density at 5 and 10 min but a clearer contribution at 20 min. These results support electrical and thermal performance assessment and short-term operational forecasting of Fresnel HCPV/T systems in sandy environments.
- 22 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8359
Open AccessNatural-Soiling Effects and Multi-Horizon Thermoelectric Forecasting of a Fresnel HCPV/T System in a Sandy Environment
Fresnel high-concentration photovoltaic/thermal (HCPV/T) systems operating in sandy environments are susceptible to natural lens soiling, which attenuates the effective concentrated solar input and alters electrical and thermal performance. Natural-soiling comparison tests were conducted over 0–28 d, and an SD-CNN-BiLSTM-Attention model was developed to forecast cell-center temperature and electrical power 5, 10, and 20 min ahead. At a surface soiling density of 10.760 g·m−2, current and electrical power decreased by 38.37% and 39.28%, respectively, relative to the concurrently operated clean-reference unit; cell-center temperature and water-tank temperature rise decreased by 7.74% and 15.13%. Thermal power also showed an overall downward trend, although the magnitude was affected by relatively large measurement uncertainty. Under grouped cross-validation, temperature RMSEs were 0.473, 0.515, and 0.555 °C at 5, 10, and 20 min, corresponding to reductions of 8.34%, 21.68%, and 44.07% relative to Persistence. Electrical-power RMSEs were 0.661, 0.618, and 0.640 W, with an 18.24% reduction relative to Persistence at 20 min. Ablation analysis showed a limited contribution from surface soiling density at 5 and 10 min but a clearer contribution at 20 min. These results support electrical and thermal performance assessment and short-term operational forecasting of Fresnel HCPV/T systems in sandy environments.
- Open Access
Drainage Characteristics and Heat Transfer Performance of Fin Surfaces in Desert Greenhouse Environments
As desertification intensifies, greenhouses in arid regions are increasingly challenged by severe water scarcity and low water utilization efficiency. Traditional greenhouse HVAC systems are often inadequate in efficiently recovering condensate water. This study addressed these challenges by investigating, through wind tunnel experiments, the fin angle and inlet wind speed for optimal condensation and heat transfer performance of a straight-fin heat exchanger in desert greenhouse environments. The experimental findings revealed that under low-temperature conditions, vertical fins facilitated gravity-driven droplet removal, resulting in a maximum condensate amount of 524.2 g within 120 min. Conversely, under high-temperature conditions, a fin angle of 45° optimally balanced turbulent disturbances and liquid film stability, producing a condensate amount of up to 887.1 g in the same timeframe. Additionally, wind speed tests at a 45° fin angle identified a critical wind speed of 1.5 m/s, beyond which the condensate amount significantly decreased. Furthermore, when the fin inclination reached or exceeded 60°, flow separation occurred, reducing the effective heat transfer area and negatively impacting the exchanger efficiency. Overall, the study provides significant insights into water conservation and sustainable environmental utilization by enhancing condensate recovery efficiency.
Open AccessDrainage Characteristics and Heat Transfer Performance of Fin Surfaces in Desert Greenhouse Environments
As desertification intensifies, greenhouses in arid regions are increasingly challenged by severe water scarcity and low water utilization efficiency. Traditional greenhouse HVAC systems are often inadequate in efficiently recovering condensate water. This study addressed these challenges by investigating, through wind tunnel experiments, the fin angle and inlet wind speed for optimal condensation and heat transfer performance of a straight-fin heat exchanger in desert greenhouse environments. The experimental findings revealed that under low-temperature conditions, vertical fins facilitated gravity-driven droplet removal, resulting in a maximum condensate amount of 524.2 g within 120 min. Conversely, under high-temperature conditions, a fin angle of 45° optimally balanced turbulent disturbances and liquid film stability, producing a condensate amount of up to 887.1 g in the same timeframe. Additionally, wind speed tests at a 45° fin angle identified a critical wind speed of 1.5 m/s, beyond which the condensate amount significantly decreased. Furthermore, when the fin inclination reached or exceeded 60°, flow separation occurred, reducing the effective heat transfer area and negatively impacting the exchanger efficiency. Overall, the study provides significant insights into water conservation and sustainable environmental utilization by enhancing condensate recovery efficiency.
- Open Access
Experimental Study on the Effect of Sand and Dust on the Performance of Photovoltaic Modules in Desert Areas
Photovoltaic power generation is one of the most effective measures to reduce greenhouse gas emissions, and the surface of photovoltaic modules in desert areas is mainly affected by sand erosion and cover, which affect power output. Therefore, a wind–sand erosion system was established to simulate the desert wind–sand environment, analyze the influence of dust erosion on the output power of the component, and observe the surface erosion morphology of the component. Then, dust particles of different sizes were selected to cover the surface of the photovoltaic module, and the temperature change and output characteristics of the backplane of the module were studied. The results show that the erosion rate increases with the increase in the erosion angle. When the erosion rate is 25 m/s and 30 m/s, the output power decreases by 9.82%~16.00% and 15.42%~24.46% at different erosion angles, respectively. As the particle size (0.05 mm~0.30 mm) deposited on the surface of the photovoltaic module gradually increases, the open-circuit voltage of the module changes little, and its maximum difference is 0.25 V. Short-circuit current and output power vary greatly; the maximum difference in short-circuit current is about 13.00%, and the maximum difference in output power is about 17.00%. Through our research, this study provides a certain reference for maximizing power generation efficiency and the clean planning of desert photovoltaic power stations.
Open AccessExperimental Study on the Effect of Sand and Dust on the Performance of Photovoltaic Modules in Desert Areas
Photovoltaic power generation is one of the most effective measures to reduce greenhouse gas emissions, and the surface of photovoltaic modules in desert areas is mainly affected by sand erosion and cover, which affect power output. Therefore, a wind–sand erosion system was established to simulate the desert wind–sand environment, analyze the influence of dust erosion on the output power of the component, and observe the surface erosion morphology of the component. Then, dust particles of different sizes were selected to cover the surface of the photovoltaic module, and the temperature change and output characteristics of the backplane of the module were studied. The results show that the erosion rate increases with the increase in the erosion angle. When the erosion rate is 25 m/s and 30 m/s, the output power decreases by 9.82%~16.00% and 15.42%~24.46% at different erosion angles, respectively. As the particle size (0.05 mm~0.30 mm) deposited on the surface of the photovoltaic module gradually increases, the open-circuit voltage of the module changes little, and its maximum difference is 0.25 V. Short-circuit current and output power vary greatly; the maximum difference in short-circuit current is about 13.00%, and the maximum difference in output power is about 17.00%. Through our research, this study provides a certain reference for maximizing power generation efficiency and the clean planning of desert photovoltaic power stations.
- Open Access
Research on Hydrogen Production System Technology Based on Photovoltaic-Photothermal Coupling Electrolyzer
Solar hydrogen production technology is a key technology for building a clean, low-carbon, safe, and efficient energy system. At present, the intermittency and volatility of renewable energy have caused a lot of “wind and light”. By combining renewable energy with electrolytic water technology to produce high-purity hydrogen and oxygen, which can be converted into electricity, the utilization rate of renewable energy can be effectively improved, while helping to improve the solar hydrogen production system. This paper summarizes and analyzes the research status and development direction of solar hydrogen production technology from three aspects. Energy supply mode: the role of solar PV systems and PT systems in this technology is analyzed. System control: the key technology and system structure of different types of electrolytic cells are introduced in detail. System economy: the economy and improvement measures of electrolytic cells are analyzed from the perspectives of cost, consumption, efficiency, and durability. Finally, the development prospects of solar hydrogen production systems in China are summarized and anticipated. This article reviews the current research status of photovoltaic-photothermal coupled electrolysis cell systems, fills the current research gap, and provides theoretical reference for the further development of solar hydrogen production systems.
Open AccessResearch on Hydrogen Production System Technology Based on Photovoltaic-Photothermal Coupling Electrolyzer
Solar hydrogen production technology is a key technology for building a clean, low-carbon, safe, and efficient energy system. At present, the intermittency and volatility of renewable energy have caused a lot of “wind and light”. By combining renewable energy with electrolytic water technology to produce high-purity hydrogen and oxygen, which can be converted into electricity, the utilization rate of renewable energy can be effectively improved, while helping to improve the solar hydrogen production system. This paper summarizes and analyzes the research status and development direction of solar hydrogen production technology from three aspects. Energy supply mode: the role of solar PV systems and PT systems in this technology is analyzed. System control: the key technology and system structure of different types of electrolytic cells are introduced in detail. System economy: the economy and improvement measures of electrolytic cells are analyzed from the perspectives of cost, consumption, efficiency, and durability. Finally, the development prospects of solar hydrogen production systems in China are summarized and anticipated. This article reviews the current research status of photovoltaic-photothermal coupled electrolysis cell systems, fills the current research gap, and provides theoretical reference for the further development of solar hydrogen production systems.
- Open Access
Effect of Sand and Dust Shading on the Output Characteristics of Solar Photovoltaic Modules in Desertification Areas
Photovoltaic power generation is rapidly developing as a kind of renewable energy that can protect the ecological environment. The establishment of photovoltaic power stations in desertification areas can play a very important role in desert windbreaks and sand fixation as well as improve the ecological environment. The realization of the effective integration of photovoltaics and deserts can have multiple benefits for the economy, society, and ecology. However, the deposition of sand and dust caused by environmental factors in desertification areas can seriously affect the power generation efficiency of PV modules. In this study, the output characteristics of photovoltaic modules were tested under three wind speed conditions (5 m/s, 10 m/s, and 15 m/s), with different sand densities, sand particle sizes, and inclination angles. The experimental study showed that the module’s output power gradually decreased with an increase in the density of accumulated sand; the sand accumulation density on the surface of the photovoltaic module increased from 0 to 40 g/m2, and the maximum output power decreased by 32.2%. As the sand particle size increased, the maximum output power of the module rose and was gradually stabilized in the three wind speed groups. As the sand particle size increased, the maximum output power of the module increased and gradually stabilized in the three wind speed groups. When the wind speed was 15 m/s, the component output power of the angle had the largest drop; the tilt angle was 60° when the relative output power rate reached the minimum (i.e., 86.5%); that is, there was electrical energy loss of approximately 13.7%. The sand particle size and accumulated sand density were the control variables related to the module temperature and the transmittance of the proportion of the impact of the module filling factor differences. According to the curve analysis of the filling factor in different sand accumulation densities, the filling factor first increased and then decreased. In this test, the filling factor at the sand accumulation density of 35 g/m2 (module temperature valley) reached the peak value. The change trend for the component filling factor under different sand particle sizes fluctuated.
Open AccessEffect of Sand and Dust Shading on the Output Characteristics of Solar Photovoltaic Modules in Desertification Areas
Photovoltaic power generation is rapidly developing as a kind of renewable energy that can protect the ecological environment. The establishment of photovoltaic power stations in desertification areas can play a very important role in desert windbreaks and sand fixation as well as improve the ecological environment. The realization of the effective integration of photovoltaics and deserts can have multiple benefits for the economy, society, and ecology. However, the deposition of sand and dust caused by environmental factors in desertification areas can seriously affect the power generation efficiency of PV modules. In this study, the output characteristics of photovoltaic modules were tested under three wind speed conditions (5 m/s, 10 m/s, and 15 m/s), with different sand densities, sand particle sizes, and inclination angles. The experimental study showed that the module’s output power gradually decreased with an increase in the density of accumulated sand; the sand accumulation density on the surface of the photovoltaic module increased from 0 to 40 g/m2, and the maximum output power decreased by 32.2%. As the sand particle size increased, the maximum output power of the module rose and was gradually stabilized in the three wind speed groups. As the sand particle size increased, the maximum output power of the module increased and gradually stabilized in the three wind speed groups. When the wind speed was 15 m/s, the component output power of the angle had the largest drop; the tilt angle was 60° when the relative output power rate reached the minimum (i.e., 86.5%); that is, there was electrical energy loss of approximately 13.7%. The sand particle size and accumulated sand density were the control variables related to the module temperature and the transmittance of the proportion of the impact of the module filling factor differences. According to the curve analysis of the filling factor in different sand accumulation densities, the filling factor first increased and then decreased. In this test, the filling factor at the sand accumulation density of 35 g/m2 (module temperature valley) reached the peak value. The change trend for the component filling factor under different sand particle sizes fluctuated.
- Open Access
- 7 November 2023
- Published by MDPI AG in Preprints.org
Effect of Sand and Dust Shading on the Output Characteristics of Solar Photovoltaic Modules in Desertification Areas
In the natural environment, sand accumulation and desertification can influence the efficiency of photovoltaic arrays. In this study, PV module output characteristics were examined under different sand particle size, varying sand densities and inclination angles, and at wind speeds of 5m/s, 10m/s, and 15m/s. Both theoretical and experimental results showed that the output power of the module declines with increasing sand density. As the sand particle size increases, the module maximum output power rises and then stabilizes. The two control variables, namely sand density and sand particle size, influence the module temperature and light transmittance distinctly. Contrary to the impact of sand density on the module filling factor curve, the module filling factor exhibits varying trends under different sand particle sizes. Additionally, the pattern of the module filling factor as a function of sand density contrasts with that of the module temperature under analogous conditions. Specifically, when the sand density on the PV module surface increases from 0 to 40g/m², there is a 32.2% reduction in maximum output power. At a wind speed of 15m/s, this reduction was found consistent across all wind speed categories. Furthermore, the trend of the module filling factor rel-ative to sand accumulation density contrasts with the module temperature trend under analogous conditions. Notably, the filling factor reached its apex at a sand accumulation density of 35g/m², which corresponded to the module temperature's nadir during the experiment.
- 7 November 2023
- Published by MDPI AG in Preprints.org
Open AccessEffect of Sand and Dust Shading on the Output Characteristics of Solar Photovoltaic Modules in Desertification Areas
In the natural environment, sand accumulation and desertification can influence the efficiency of photovoltaic arrays. In this study, PV module output characteristics were examined under different sand particle size, varying sand densities and inclination angles, and at wind speeds of 5m/s, 10m/s, and 15m/s. Both theoretical and experimental results showed that the output power of the module declines with increasing sand density. As the sand particle size increases, the module maximum output power rises and then stabilizes. The two control variables, namely sand density and sand particle size, influence the module temperature and light transmittance distinctly. Contrary to the impact of sand density on the module filling factor curve, the module filling factor exhibits varying trends under different sand particle sizes. Additionally, the pattern of the module filling factor as a function of sand density contrasts with that of the module temperature under analogous conditions. Specifically, when the sand density on the PV module surface increases from 0 to 40g/m², there is a 32.2% reduction in maximum output power. At a wind speed of 15m/s, this reduction was found consistent across all wind speed categories. Furthermore, the trend of the module filling factor rel-ative to sand accumulation density contrasts with the module temperature trend under analogous conditions. Notably, the filling factor reached its apex at a sand accumulation density of 35g/m², which corresponded to the module temperature's nadir during the experiment.
- Open Access
Experimental and Numerical Study of the Ice Storage Process and Material Properties of Ice Storage Coils
The coiled ice-storage-based air conditioning system plays a significant role in enhancing grid peak regulation and improving cooling economy. This paper presents theoretical and experimental studies conducted on the ice storage process of coiled ice storage air conditioning technology. The cooling of water is divided into two stages:10.0 °C to 4.0 °C and 4.0 °C to below 0.0 °C. Initially, the ice storage process forms an ice layer with a thickness of 2.50 mm on the lower surface of the coil, but eventually, the ice layer on the upper surface becomes 3.85 mm thicker than the lower surface as a result of the natural convection of water and density reversal at 4.0 °C. Furthermore, the impact of three coils with different thermal conductivity on the ice storage process was evaluated. It was observed that the thermal conductivity of R-HDPE (reinforced high-density polyethylene) was only 2.6 W/(m·K) higher than HDPE (high-density polyethylene), yet it reduced the freezing time by 34.85%, while the thermal conductivity of steel was 37.4 W/(m·K) higher than R-HDPE, but only decreased the freezing time by 9.40%. The results demonstrated that the rate of ice accumulation increased with thermal conductivity. However, when the coil material’s thermal conductivity surpassed that of ice, the further increase of thermal conductivity gradually weakened its impact on the ice storage rate.
Open AccessExperimental and Numerical Study of the Ice Storage Process and Material Properties of Ice Storage Coils
The coiled ice-storage-based air conditioning system plays a significant role in enhancing grid peak regulation and improving cooling economy. This paper presents theoretical and experimental studies conducted on the ice storage process of coiled ice storage air conditioning technology. The cooling of water is divided into two stages:10.0 °C to 4.0 °C and 4.0 °C to below 0.0 °C. Initially, the ice storage process forms an ice layer with a thickness of 2.50 mm on the lower surface of the coil, but eventually, the ice layer on the upper surface becomes 3.85 mm thicker than the lower surface as a result of the natural convection of water and density reversal at 4.0 °C. Furthermore, the impact of three coils with different thermal conductivity on the ice storage process was evaluated. It was observed that the thermal conductivity of R-HDPE (reinforced high-density polyethylene) was only 2.6 W/(m·K) higher than HDPE (high-density polyethylene), yet it reduced the freezing time by 34.85%, while the thermal conductivity of steel was 37.4 W/(m·K) higher than R-HDPE, but only decreased the freezing time by 9.40%. The results demonstrated that the rate of ice accumulation increased with thermal conductivity. However, when the coil material’s thermal conductivity surpassed that of ice, the further increase of thermal conductivity gradually weakened its impact on the ice storage rate.
- Open Access
Comparative Analysis of the Filling Mass of Vertical Heat Exchanger Tubes on the Thermal Environment of Arched Greenhouses
The greenhouse’s energy consumption is a major limiting factor for output and development. To address this, it is necessary to adopt green and low-carbon heating technologies to replace traditional fuels. This will not only help conserve energy but will also reduce emissions, thereby improving the thermal environmental conditions for agriculture. This paper aims to research and develop a vertical heat exchange tube array device specifically designed for greenhouses. The focus is on enhancing the passive heat absorption and heat storage efficiency of the device and its influence on the thermal environment of the greenhouse. In order to improve the heat absorption and storage efficiency of the heat exchanger device and its impact on the greenhouse thermal environment, experimental comparative analysis was conducted using air, water, and phase-change materials as working fluids inside the pipes. Through a combination of experiments and simulations, it was verified that the heat exchanger device is capable of actively regulating the greenhouse thermal environment. The results show that heat exchangers of all three types of working fluids can effectively improve the stability of soil temperature and play a “shifting the peak and filling the valley” role in regulating the indoor air temperature while positively regulating the relative humidity of the air. Notably, when the working fluid is a phase-change material, it has the most significant impact on the thermal environment of the greenhouse.
Open AccessComparative Analysis of the Filling Mass of Vertical Heat Exchanger Tubes on the Thermal Environment of Arched Greenhouses
The greenhouse’s energy consumption is a major limiting factor for output and development. To address this, it is necessary to adopt green and low-carbon heating technologies to replace traditional fuels. This will not only help conserve energy but will also reduce emissions, thereby improving the thermal environmental conditions for agriculture. This paper aims to research and develop a vertical heat exchange tube array device specifically designed for greenhouses. The focus is on enhancing the passive heat absorption and heat storage efficiency of the device and its influence on the thermal environment of the greenhouse. In order to improve the heat absorption and storage efficiency of the heat exchanger device and its impact on the greenhouse thermal environment, experimental comparative analysis was conducted using air, water, and phase-change materials as working fluids inside the pipes. Through a combination of experiments and simulations, it was verified that the heat exchanger device is capable of actively regulating the greenhouse thermal environment. The results show that heat exchangers of all three types of working fluids can effectively improve the stability of soil temperature and play a “shifting the peak and filling the valley” role in regulating the indoor air temperature while positively regulating the relative humidity of the air. Notably, when the working fluid is a phase-change material, it has the most significant impact on the thermal environment of the greenhouse.