Katsunori Ishii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Katsunori Ishii has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Kunio Awazu
Osaka University, Graduate School of Engineering, Suita
11 shared publications Kazushi Yoshikawa
Department of Operative Dentistry, Osaka Dental University
3 shared publicationsKazuyo Yamamoto
Department of Operative Dentistry, Osaka Dental University
3 shared publicationsKenzo Yasuo
Department of Operative Dentistry, Osaka Dental University
3 shared publications- Hisanao Hazama
Osaka University
2 shared publications Kota Omiya
Osaka Univ. (Japan)
2 shared publications
Latest Publications
- 1 January 2016
- Published by Japanese Society for Laser Dentistry in Journal of Japanese Society for Laser Dentistry
- Vol. 27 (2) , 51-55
Comparison of Ablation Characteristics of Bovine Demineralized Dentin Using Nanosecond Pulsed Lasers at the Wavelengths of 2.94 and 5.80μm for Selective Removal of Caries
- 1 January 2016
- Published by Japanese Society for Laser Dentistry in Journal of Japanese Society for Laser Dentistry
- Vol. 27 (2) , 51-55
Comparison of Ablation Characteristics of Bovine Demineralized Dentin Using Nanosecond Pulsed Lasers at the Wavelengths of 2.94 and 5.80μm for Selective Removal of Caries
- 1 January 2015
- Published by Optica Publishing Group
- p. 95371C
Quantitative evaluation of lipid concentration in atherosclerotic plaque phantom by near-infrared multispectral angioscope at wavelengths around 1200 nm
Atherosclerosis is a primary cause of critical ischemic diseases like heart infarction or stroke. A method that can provide detailed information about the stability of atherosclerotic plaques is required. We focused on spectroscopic techniques that could evaluate the chemical composition of lipid in plaques. A novel angioscope using multispectral imaging at wavelengths around 1200 nm for quantitative evaluation of atherosclerotic plaques was developed. The angioscope consists of a halogen lamp, an indium gallium arsenide (InGaAs) camera, 3 optical band pass filters transmitting wavelengths of 1150, 1200, and 1300 nm, an image fiber having 0.7 mm outer diameter, and an irradiation fiber which consists of 7 multimode fibers. Atherosclerotic plaque phantoms with 100, 60, 20 vol.% of lipid were prepared and measured by the multispectral angioscope. The acquired datasets were processed by spectral angle mapper (SAM) method. As a result, simulated plaque areas in atherosclerotic plaque phantoms that could not be detected by an angioscopic visible image could be clearly enhanced. In addition, quantitative evaluation of atherosclerotic plaque phantoms based on the lipid volume fractions was performed up to 20 vol.%. These results show the potential of a multispectral angioscope at wavelengths around 1200 nm for quantitative evaluation of the stability of atherosclerotic plaques.
- 1 January 2015
- Published by Optica Publishing Group
- p. 95371C
Quantitative evaluation of lipid concentration in atherosclerotic plaque phantom by near-infrared multispectral angioscope at wavelengths around 1200 nm
Atherosclerosis is a primary cause of critical ischemic diseases like heart infarction or stroke. A method that can provide detailed information about the stability of atherosclerotic plaques is required. We focused on spectroscopic techniques that could evaluate the chemical composition of lipid in plaques. A novel angioscope using multispectral imaging at wavelengths around 1200 nm for quantitative evaluation of atherosclerotic plaques was developed. The angioscope consists of a halogen lamp, an indium gallium arsenide (InGaAs) camera, 3 optical band pass filters transmitting wavelengths of 1150, 1200, and 1300 nm, an image fiber having 0.7 mm outer diameter, and an irradiation fiber which consists of 7 multimode fibers. Atherosclerotic plaque phantoms with 100, 60, 20 vol.% of lipid were prepared and measured by the multispectral angioscope. The acquired datasets were processed by spectral angle mapper (SAM) method. As a result, simulated plaque areas in atherosclerotic plaque phantoms that could not be detected by an angioscopic visible image could be clearly enhanced. In addition, quantitative evaluation of atherosclerotic plaque phantoms based on the lipid volume fractions was performed up to 20 vol.%. These results show the potential of a multispectral angioscope at wavelengths around 1200 nm for quantitative evaluation of the stability of atherosclerotic plaques.
- 1 January 2014
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 35 (2) , 158-164
Influence of Diffuse Reflectance Measurement Accuracy on Scattering Coefficient in Determination of Optical Property with Integrating Sphere Optics
- 1 January 2014
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 35 (2) , 158-164
Influence of Diffuse Reflectance Measurement Accuracy on Scattering Coefficient in Determination of Optical Property with Integrating Sphere Optics
- 8 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8565, 85654G
Near-infrared hyperspectral imaging of atherosclerotic plaque in WHHLMI rabbit artery
Hyperspectral imaging (HSI) of rabbit atherosclerotic plaque in near-infrared (NIR) range from 1150 to 2400 nm was demonstrated. A method to identify vulnerable plaques that are likely to cause acute coronary events has been required. The object of this study is identifying vulnerable plaques by NIR-HSI for an angioscopic application. In this study, we observed the hyperspectral images of the atherosclerotic plaque in WHHLMI rabbit (atherosclerotic rabbit) artery under simulated angioscopic conditions by NIR-HSI. NIR-HSI system was constructed by a NIR super continuum light and a mercury-cadmium-telluride camera. Spectral absorbance values (log (1/R) data) were obtained in the wavelength range from 1150 to 2400 nm at 10 nm intervals. The hyperspectral images were constructed with spectral angle mapper algorithm. As a result, the detections of atherosclerotic plaque under angioscopic observation conditions were achieved especially in the wavelength around 1200 nm, which corresponds to the second overtone of CH stretching vibration mode. The NIR-HSI was considered to serve as an angioscopic diagnosis technique to identify vulnerable plaques without clamping and saline injection.
- 8 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8565, 85654G
Near-infrared hyperspectral imaging of atherosclerotic plaque in WHHLMI rabbit artery
Hyperspectral imaging (HSI) of rabbit atherosclerotic plaque in near-infrared (NIR) range from 1150 to 2400 nm was demonstrated. A method to identify vulnerable plaques that are likely to cause acute coronary events has been required. The object of this study is identifying vulnerable plaques by NIR-HSI for an angioscopic application. In this study, we observed the hyperspectral images of the atherosclerotic plaque in WHHLMI rabbit (atherosclerotic rabbit) artery under simulated angioscopic conditions by NIR-HSI. NIR-HSI system was constructed by a NIR super continuum light and a mercury-cadmium-telluride camera. Spectral absorbance values (log (1/R) data) were obtained in the wavelength range from 1150 to 2400 nm at 10 nm intervals. The hyperspectral images were constructed with spectral angle mapper algorithm. As a result, the detections of atherosclerotic plaque under angioscopic observation conditions were achieved especially in the wavelength around 1200 nm, which corresponds to the second overtone of CH stretching vibration mode. The NIR-HSI was considered to serve as an angioscopic diagnosis technique to identify vulnerable plaques without clamping and saline injection.
- Open Access
- 1 January 2013
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 34 (1) , 3-8
Continuous Measurement of Attenuation Coefficient of Biological Tissue during Laser Coagulation by Optical Coherence Tomography
- 1 January 2013
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 34 (1) , 3-8
Open AccessContinuous Measurement of Attenuation Coefficient of Biological Tissue during Laser Coagulation by Optical Coherence Tomography
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8208, 82080K
Minimally invasive treatment of carious dentin with a nanosecond pulsed laser at 5.8 μm wavelength
Conventional lasers, Er:YAG laser and Er,Cr:YSGG laser, lack the ability for selective excavation to discriminate carious tissue only because they use the laser tissue interaction derived from a strong absorption of water. Based on the absorption property of carious dentin, characteristic absorption bands around 6 μm are candidate for selective excavation. Our group has already observed the difference of ablation depth between demineralized and normal dentin in the wavelength range from 5.75 to 6.60 μm. Also this study has showed the effectiveness of 5.8 μm. Objective of this study is to determine optimal irradiation parameters of selective excavation by using 5.8 μm. Bovine dentin plates demineralized by soaking in lactic acid solution were used as a carious dentin model. A nanosecond pulsed laser at 5.8 μm wavelength was obtained by difference-frequency generation technique. The laser delivers 5 ns pulse width at a repetition rate of 10 Hz. After irradiation, morphological change and measurement of ablation depth was observed with a scanning electron microscope and a confocal laser microscope, respectively. In 5.8 μm wavelength, high ablation efficiency with a low thermal side effect was observed. 5.8 μm wavelength provides a selective excavation technique for minimal intervention.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8208, 82080K
Minimally invasive treatment of carious dentin with a nanosecond pulsed laser at 5.8 μm wavelength
Conventional lasers, Er:YAG laser and Er,Cr:YSGG laser, lack the ability for selective excavation to discriminate carious tissue only because they use the laser tissue interaction derived from a strong absorption of water. Based on the absorption property of carious dentin, characteristic absorption bands around 6 μm are candidate for selective excavation. Our group has already observed the difference of ablation depth between demineralized and normal dentin in the wavelength range from 5.75 to 6.60 μm. Also this study has showed the effectiveness of 5.8 μm. Objective of this study is to determine optimal irradiation parameters of selective excavation by using 5.8 μm. Bovine dentin plates demineralized by soaking in lactic acid solution were used as a carious dentin model. A nanosecond pulsed laser at 5.8 μm wavelength was obtained by difference-frequency generation technique. The laser delivers 5 ns pulse width at a repetition rate of 10 Hz. After irradiation, morphological change and measurement of ablation depth was observed with a scanning electron microscope and a confocal laser microscope, respectively. In 5.8 μm wavelength, high ablation efficiency with a low thermal side effect was observed. 5.8 μm wavelength provides a selective excavation technique for minimal intervention.
- 25 February 2011
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 1, 513-516
Thermal neutron field with D-T neutron source for BNCT
- 25 February 2011
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 1, 513-516
Thermal neutron field with D-T neutron source for BNCT
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7884, 78840L-78840
Selective treatment of carious dentin using a mid-infrared tunable pulsed laser at 6 μm wavelength range
Optical technologies have good potential for caries detection, prevention, excavation, and the realization of minimal intervention dentistry. This study aimed to develop a selective excavation technique of carious tissue using the specific absorption in 6 μm wavelength range. Bovine dentin demineralized with lactic acid solution was used as a carious dentin model. A mid-infrared tunable pulsed laser was obtained by difference-frequency generation technique. The wavelength was tuned to 6.02 and 6.42 μm which correspond to absorption bands called amide I and amide II, respectively. The laser delivers 5 ns pulse width at a repetition rate of 10 Hz. The morphological change after irradiation was observed with a scanning electron microscope, and the measurement of ablation depth was performed with a confocal laser microscope. At λ = 6.02 μm and the average power density of 15 W/cm2, demineralized dentin was removed selectively with less-invasive effect on sound dentin. The wavelength of 6.42 μm also showed the possibility of selective removal. High ablation efficiency and low thermal side effect were observed using the nanosecond pulsed laser with λ = 6.02 μm. In the near future, development of compact laser device will open the minimal invasive laser treatment to the dental clinic.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7884, 78840L-78840
Selective treatment of carious dentin using a mid-infrared tunable pulsed laser at 6 μm wavelength range
Optical technologies have good potential for caries detection, prevention, excavation, and the realization of minimal intervention dentistry. This study aimed to develop a selective excavation technique of carious tissue using the specific absorption in 6 μm wavelength range. Bovine dentin demineralized with lactic acid solution was used as a carious dentin model. A mid-infrared tunable pulsed laser was obtained by difference-frequency generation technique. The wavelength was tuned to 6.02 and 6.42 μm which correspond to absorption bands called amide I and amide II, respectively. The laser delivers 5 ns pulse width at a repetition rate of 10 Hz. The morphological change after irradiation was observed with a scanning electron microscope, and the measurement of ablation depth was performed with a confocal laser microscope. At λ = 6.02 μm and the average power density of 15 W/cm2, demineralized dentin was removed selectively with less-invasive effect on sound dentin. The wavelength of 6.42 μm also showed the possibility of selective removal. High ablation efficiency and low thermal side effect were observed using the nanosecond pulsed laser with λ = 6.02 μm. In the near future, development of compact laser device will open the minimal invasive laser treatment to the dental clinic.
- 1 January 2010
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 31 (2) , 152-157
Determination of the Optical Property of Herniated Nucleus Pulposus and a Discussion about an Optimal Wavelength of Percutaneous Laser Disk Decompression
- 1 January 2010
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 31 (2) , 152-157
Determination of the Optical Property of Herniated Nucleus Pulposus and a Discussion about an Optimal Wavelength of Percutaneous Laser Disk Decompression
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2009 (1094687X) , 4150-4153
Novel laser therapy and diagnosis using mid-infrared laser
Mid-infrared (MIR) laser with a specific wavelength can excite the corresponding biomolecular site to regulate chemical, thermal and mechanical interactions to biological molecules and tissues. In laser surgery and medicine, tunable MIR laser irradiation can realize the safety regulation of therapeutic effect, less-invasive treatments and the special diagnosis by vibrational spectroscopic information. This paper showed a novel therapeutic and diagnostic applications using tunable MIR laser.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2009 (1094687X) , 4150-4153
Novel laser therapy and diagnosis using mid-infrared laser
Mid-infrared (MIR) laser with a specific wavelength can excite the corresponding biomolecular site to regulate chemical, thermal and mechanical interactions to biological molecules and tissues. In laser surgery and medicine, tunable MIR laser irradiation can realize the safety regulation of therapeutic effect, less-invasive treatments and the special diagnosis by vibrational spectroscopic information. This paper showed a novel therapeutic and diagnostic applications using tunable MIR laser.