Norbert Strobel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Norbert Strobel has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Joachim Hornegger
Friedrich-Alexander-Univ. Erlangen-Nürnberg (Germany)
3 shared publications - Alexander Brost
Stanford Univ. (United States)
2 shared publications - Rebecca Fahrig
Stanford Univ. (United States)
2 shared publications Bernhard Meyer
Siemens AG (Germany)
1 shared publicationChrisian Gosch
Volume Graphics
1 shared publicationChristoph Poliwoda
Volume Graphics
1 shared publication
Latest Publications
- 8 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8671, 86710D
Respiratory motion influence on catheter contact force during radio frequency ablation procedures
Minimally invasive catheter ablation is a common treatment option for atrial fibrillation. A common treatment strategy is pulmonary vein isolation. In this case, individual ablation points need to be placed around the ostia of the pulmonary veins attached to the left atrium to generate transmural lesions and thereby block electric signals. To achieve a durable transmural lesion, the tip of the catheter has to be stable with a sufficient tissue contact during radio-frequency ablation. Besides the steerable interface operated by the physician, the movement of the catheter is also influenced by the heart and breathing motion - particularly during ablation. In this paper we investigate the influence of breathing motion on different areas of the endocardium during radio frequency ablation. To this end, we analyze the frequency spectrum of the continuous catheter contact force to identify areas with increased breathing motion using a classification method. This approach has been applied to clinical patient data acquired during three pulmonary vein isolation procedures. Initial findings show that motion due to respiration is more pronounced at the roof and around the right pulmonary veins.
- 8 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8671, 86710D
Respiratory motion influence on catheter contact force during radio frequency ablation procedures
Minimally invasive catheter ablation is a common treatment option for atrial fibrillation. A common treatment strategy is pulmonary vein isolation. In this case, individual ablation points need to be placed around the ostia of the pulmonary veins attached to the left atrium to generate transmural lesions and thereby block electric signals. To achieve a durable transmural lesion, the tip of the catheter has to be stable with a sufficient tissue contact during radio-frequency ablation. Besides the steerable interface operated by the physician, the movement of the catheter is also influenced by the heart and breathing motion - particularly during ablation. In this paper we investigate the influence of breathing motion on different areas of the endocardium during radio frequency ablation. To this end, we analyze the frequency spectrum of the continuous catheter contact force to identify areas with increased breathing motion using a classification method. This approach has been applied to clinical patient data acquired during three pulmonary vein isolation procedures. Initial findings show that motion due to respiration is more pronounced at the roof and around the right pulmonary veins.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261, 72611Z
Accuracy of x-ray image-based 3D localization from two C-arm views: a comparison between an ideal system and a real device
Arm X-ray imaging devices are commonly used for minimally invasive cardiovascular or other interventional procedures. Calibrated state-of-the-art systems can, however, not only be used for 2D imaging but also for three-dimensional reconstruction either using tomographic techniques or even stereotactic approaches. To evaluate the accuracy of X-ray object localization from two views, a simulation study assuming an ideal imaging geometry was carried out first. This was backed up with a phantom experiment involving a real C-arm angiography system. Both studies were based on a phantom comprising five point objects. These point objects were projected onto a flat-panel detector under different C-arm view positions. The resulting 2D positions were perturbed by adding Gaussian noise to simulate 2D point localization errors. In the next step, 3D point positions were triangulated from two views. A 3D error was computed by taking differences between the reconstructed 3D positions using the perturbed 2D positions and the initial 3D positions of the five points. This experiment was repeated for various C-arm angulations involving angular differences ranging from 15° to 165°. The smallest 3D reconstruction error was achieved, as expected, by views that were 90° degrees apart. In this case, the simulation study yielded a 3D error of 0.82 mm ± 0.24 mm (mean ± standard deviation) for 2D noise with a standard deviation of 1.232 mm (4 detector pixels). The experimental result for this view configuration obtained on an AXIOM Artis C-arm (Siemens AG, Healthcare Sector, Forchheim, Germany) system was 0.98 mm ± 0.29 mm, respectively. These results show that state-of-the-art C-arm systems can localize instruments with millimeter accuracy, and that they can accomplish this almost as well as an idealized theoretical counterpart. High stereotactic localization accuracy, good patient access, and CT-like 3D imaging capabilities render state-of-the-art C-arm systems ideal devices for X-ray based minimally invasive procedures.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261, 72611Z
Accuracy of x-ray image-based 3D localization from two C-arm views: a comparison between an ideal system and a real device
Arm X-ray imaging devices are commonly used for minimally invasive cardiovascular or other interventional procedures. Calibrated state-of-the-art systems can, however, not only be used for 2D imaging but also for three-dimensional reconstruction either using tomographic techniques or even stereotactic approaches. To evaluate the accuracy of X-ray object localization from two views, a simulation study assuming an ideal imaging geometry was carried out first. This was backed up with a phantom experiment involving a real C-arm angiography system. Both studies were based on a phantom comprising five point objects. These point objects were projected onto a flat-panel detector under different C-arm view positions. The resulting 2D positions were perturbed by adding Gaussian noise to simulate 2D point localization errors. In the next step, 3D point positions were triangulated from two views. A 3D error was computed by taking differences between the reconstructed 3D positions using the perturbed 2D positions and the initial 3D positions of the five points. This experiment was repeated for various C-arm angulations involving angular differences ranging from 15° to 165°. The smallest 3D reconstruction error was achieved, as expected, by views that were 90° degrees apart. In this case, the simulation study yielded a 3D error of 0.82 mm ± 0.24 mm (mean ± standard deviation) for 2D noise with a standard deviation of 1.232 mm (4 detector pixels). The experimental result for this view configuration obtained on an AXIOM Artis C-arm (Siemens AG, Healthcare Sector, Forchheim, Germany) system was 0.98 mm ± 0.29 mm, respectively. These results show that state-of-the-art C-arm systems can localize instruments with millimeter accuracy, and that they can accomplish this almost as well as an idealized theoretical counterpart. High stereotactic localization accuracy, good patient access, and CT-like 3D imaging capabilities render state-of-the-art C-arm systems ideal devices for X-ray based minimally invasive procedures.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2620-2628
Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP
Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. The goal is to bring 3D imaging to the interventional suite for improved therapy planning, guidance, and monitoring. For the reconstruction of 3D cardiac image data, a complete set of projections from a specific heart phase is required. One approach to reduce motion blurring caused by the beating heart is to acquire multiple sweeps using the C-arm and retrospectively select the projections that are closest to the desired cardiac phase. In order to further improve the temporal resolution, novel image processing algorithms that utilize retrospective motion correction were investigated in this study. The main focus of this work is to extend the well established FDK algorithm to incorporate motion correction during the back-projection step using a subject specific computed motion field. In a simulation study we show that motion blurring can be decreased significantly using the subjects' individual estimated heart motion based on a time series of retrospectively gated FDK reconstructions. In our experiments using an animal model we investigated the following two scenarios: (I) Can the image quality from a single sweep be improved given a subjects' individual prior computed motion field? (II) Can improved image quality be achieved using the full temporal resolution of a multi-sweep scan for motion estimation in combination with motion correction? Our results show that increasing temporal resolution using an first order estimated 4D motion vector field of the subjects' individual heart motion in the FDK-4D algorithm can decrease motion blurring substantially for both investigated scenarios.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2620-2628
Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP
Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. The goal is to bring 3D imaging to the interventional suite for improved therapy planning, guidance, and monitoring. For the reconstruction of 3D cardiac image data, a complete set of projections from a specific heart phase is required. One approach to reduce motion blurring caused by the beating heart is to acquire multiple sweeps using the C-arm and retrospectively select the projections that are closest to the desired cardiac phase. In order to further improve the temporal resolution, novel image processing algorithms that utilize retrospective motion correction were investigated in this study. The main focus of this work is to extend the well established FDK algorithm to incorporate motion correction during the back-projection step using a subject specific computed motion field. In a simulation study we show that motion blurring can be decreased significantly using the subjects' individual estimated heart motion based on a time series of retrospectively gated FDK reconstructions. In our experiments using an animal model we investigated the following two scenarios: (I) Can the image quality from a single sweep be improved given a subjects' individual prior computed motion field? (II) Can improved image quality be achieved using the full temporal resolution of a multi-sweep scan for motion estimation in combination with motion correction? Our results show that increasing temporal resolution using an first order estimated 4D motion vector field of the subjects' individual heart motion in the FDK-4D algorithm can decrease motion blurring substantially for both investigated scenarios.
- 29 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5747, 378-388
Estimating 0thand 1stmoments in C-arm CT data for extrapolating truncated projections
C-Arm CT systems suffer from artifacts due to truncated projections caused by a finite detector size. One method used to mitigate the truncation artifacts is projection extrapolation without a priori knowledge. This work focuses on estimating the 0th and 1st moments of an image, which can be used to extrapolate a set of truncated projections. If some projections are not truncated, then accurate estimation of the moments can be achieved using only those projections. The more difficult case arises when all projections are truncated by some amount. For this case we make simplifying assumptions and fit the truncated projections with elliptical profiles. From this fit, we estimate the 0th and 1st moments of the original image. These estimated moments are then used to perform an extrapolation of the truncated projections, where each projection meets a constraint based on the 0th and 1st moments (moment extrapolation). This work focuses on how accurate moment estimates must be for moment extrapolation to be effective. The algorithm was tested on simulated and real data for the head, thorax, and abdomen, and those results were compared to symmetric mirroring by Ohnesorge et al., another extrapolation technique that requires no a priori knowledge. Overall, moment estimation and mass extrapolation alleviates a large amount of image artifact, and can improve on other extrapolation techniques. For the real CT head and abdominal data, the average reconstruction error for mass extrapolation was 48% less than the reconstruction error for symmetric mirroring.
- 29 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5747, 378-388
Estimating 0thand 1stmoments in C-arm CT data for extrapolating truncated projections
C-Arm CT systems suffer from artifacts due to truncated projections caused by a finite detector size. One method used to mitigate the truncation artifacts is projection extrapolation without a priori knowledge. This work focuses on estimating the 0th and 1st moments of an image, which can be used to extrapolate a set of truncated projections. If some projections are not truncated, then accurate estimation of the moments can be achieved using only those projections. The more difficult case arises when all projections are truncated by some amount. For this case we make simplifying assumptions and fit the truncated projections with elliptical profiles. From this fit, we estimate the 0th and 1st moments of the original image. These estimated moments are then used to perform an extrapolation of the truncated projections, where each projection meets a constraint based on the 0th and 1st moments (moment extrapolation). This work focuses on how accurate moment estimates must be for moment extrapolation to be effective. The algorithm was tested on simulated and real data for the head, thorax, and abdomen, and those results were compared to symmetric mirroring by Ohnesorge et al., another extrapolation technique that requires no a priori knowledge. Overall, moment estimation and mass extrapolation alleviates a large amount of image artifact, and can improve on other extrapolation techniques. For the real CT head and abdominal data, the average reconstruction error for mass extrapolation was 48% less than the reconstruction error for symmetric mirroring.
- 1 January 2003
- Published by Springer Nature
- p. 106-110
Multiresolution Data Handling for Visualization of Very Large Data Sets
- 1 January 2003
- Published by Springer Nature
- p. 106-110
Multiresolution Data Handling for Visualization of Very Large Data Sets