JHJoachim Hornegger

Joachim Hornegger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joachim Hornegger has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Respiratory motion influence on catheter contact force during radio frequency ablation procedures

    by Martin Koch, Alexander Brost, Joachim Hornegger, Norbert Strobel

    Minimally invasive catheter ablation is a common treatment option for atrial fibrillation. A common treatment strategy is pulmonary vein isolation. In this case, individual ablation points need to be placed around the ostia of the pulmonary veins attached to the left atrium to generate transmural lesions and thereby block electric signals. To achieve a durable transmural lesion, the tip of the catheter has to be stable with a sufficient tissue contact during radio-frequency ablation. Besides the steerable interface operated by the physician, the movement of the catheter is also influenced by the heart and breathing motion - particularly during ablation. In this paper we investigate the influence of breathing motion on different areas of the endocardium during radio frequency ablation. To this end, we analyze the frequency spectrum of the continuous catheter contact force to identify areas with increased breathing motion using a classification method. This approach has been applied to clinical patient data acquired during three pulmonary vein isolation procedures. Initial findings show that motion due to respiration is more pronounced at the roof and around the right pulmonary veins.

  • Automatic measurement of contrast bolus distribution in carotid arteries using a C-arm angiography system to support interventional perfusion imaging

    by Andreas Fieselmann, Arundhuti Ganguly, Deuerling-Zheng Yu, Jan Boese, Joachim Hornegger, Rebecca Fahrig

    Brain perfusion CT using a C-arm angiography system capable of CT-like imaging could optimize patient treatment during stroke therapy procedures. For this application, an intra-arterial contrast bolus injection at the aortic arch could be used provided that the location of the injection catheter enables uniform distribution of the bolus into the two common carotid arteries (CCA). In this work, we present a novel method to support optimal injection catheter placement by providing additional quantitative information about the distribution of the contrast bolus into the CCAs. Our fully automatic method uses 2-D digital subtraction angiography (DSA) images following a test bolus injection. It segments both CCAs and computes the relative contrast distribution. We have tested the method in DSA data sets from 5 healthy pigs and our method achieved successful segmentation of both CCAs in all data sets. The results showed that the contrast is uniformly distributed (mean relative difference less or equal than 10%) if the injection location is properly chosen.


  • Accuracy of x-ray image-based 3D localization from two C-arm views: a comparison between an ideal system and a real device

    by Alexander Brost, Norbert Strobel, Liron Yatziv, Wesley Gilson, Bernhard Meyer, Joachim Hornegger, Jonathan Lewin, Frank Wacker

    Arm X-ray imaging devices are commonly used for minimally invasive cardiovascular or other interventional procedures. Calibrated state-of-the-art systems can, however, not only be used for 2D imaging but also for three-dimensional reconstruction either using tomographic techniques or even stereotactic approaches. To evaluate the accuracy of X-ray object localization from two views, a simulation study assuming an ideal imaging geometry was carried out first. This was backed up with a phantom experiment involving a real C-arm angiography system. Both studies were based on a phantom comprising five point objects. These point objects were projected onto a flat-panel detector under different C-arm view positions. The resulting 2D positions were perturbed by adding Gaussian noise to simulate 2D point localization errors. In the next step, 3D point positions were triangulated from two views. A 3D error was computed by taking differences between the reconstructed 3D positions using the perturbed 2D positions and the initial 3D positions of the five points. This experiment was repeated for various C-arm angulations involving angular differences ranging from 15° to 165°. The smallest 3D reconstruction error was achieved, as expected, by views that were 90° degrees apart. In this case, the simulation study yielded a 3D error of 0.82 mm ± 0.24 mm (mean ± standard deviation) for 2D noise with a standard deviation of 1.232 mm (4 detector pixels). The experimental result for this view configuration obtained on an AXIOM Artis C-arm (Siemens AG, Healthcare Sector, Forchheim, Germany) system was 0.98 mm ± 0.29 mm, respectively. These results show that state-of-the-art C-arm systems can localize instruments with millimeter accuracy, and that they can accomplish this almost as well as an idealized theoretical counterpart. High stereotactic localization accuracy, good patient access, and CT-like 3D imaging capabilities render state-of-the-art C-arm systems ideal devices for X-ray based minimally invasive procedures.


  • Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP

    by M. Prummer, L. Wigstrom, J. Hornegger, J. Boese, G. Lauritsch, N. Strobel, R. Fahrig

    Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. The goal is to bring 3D imaging to the interventional suite for improved therapy planning, guidance, and monitoring. For the reconstruction of 3D cardiac image data, a complete set of projections from a specific heart phase is required. One approach to reduce motion blurring caused by the beating heart is to acquire multiple sweeps using the C-arm and retrospectively select the projections that are closest to the desired cardiac phase. In order to further improve the temporal resolution, novel image processing algorithms that utilize retrospective motion correction were investigated in this study. The main focus of this work is to extend the well established FDK algorithm to incorporate motion correction during the back-projection step using a subject specific computed motion field. In a simulation study we show that motion blurring can be decreased significantly using the subjects' individual estimated heart motion based on a time series of retrospectively gated FDK reconstructions. In our experiments using an animal model we investigated the following two scenarios: (I) Can the image quality from a single sweep be improved given a subjects' individual prior computed motion field? (II) Can improved image quality be achieved using the full temporal resolution of a multi-sweep scan for motion estimation in combination with motion correction? Our results show that increasing temporal resolution using an first order estimated 4D motion vector field of the subjects' individual heart motion in the FDK-4D algorithm can decrease motion blurring substantially for both investigated scenarios.


  • Probabilistic Semantic Analysis of Speech

    by Jürgen Haas, Joachim Hornegger, Richard Huber, Heinrich Niemann