Jacob T. Trueb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jacob T. Trueb has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Selim Unlu
Department of Electrical and Computer Engineering, Boston University, Boston, USA
3 shared publications - John H. Connor
National Emerging Infectious Diseases Laboratories, Boston University, Boston, MA, USA
2 shared publications - Ahmet Tuysuzoglu
Department of Electrical and Computer Engineering, Boston University, Boston, MA, USA
1 shared publication - Alexander P. Reddington
Department of Electrical and Computer Engineering, Boston University, Boston, MA, USA
1 shared publication - Ayca Yalcin Ozkumur
Electrical and Computer Engineering, Boston University, Boston, Massachusetts United States 02215
1 shared publication - Carlos A. Lopez
Department of Electrical and Computer Engineering, Boston University, Boston, MA, USA
1 shared publication
Latest Publications
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (1) , 1-7
Interferometric Detection and Enumeration of Viral Particles using Si-Based Microfluidics
Single-Particle Interferometric Reflectance Imaging Sensor (SP-IRIS) enables optical visualization and characterization of individual nanoparticles without any labels. Using this technique, we have shown end point and real-time detection of viral particles using laminate based active and passive cartridge configurations. Here, we present a new concept for low-cost microfluidic integration of the sensor chips into compact cartridges through utilization of readily available Si fabrication technologies. This new cartridge configuration allows simultaneous detection of individual virus binding events on a 9-spot microarray, and will provide the needed simplicity and robustness for routine real-time operation for discrete detection of viral particles in a multiplex format.
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (1) , 1-7
Interferometric Detection and Enumeration of Viral Particles using Si-Based Microfluidics
Single-Particle Interferometric Reflectance Imaging Sensor (SP-IRIS) enables optical visualization and characterization of individual nanoparticles without any labels. Using this technique, we have shown end point and real-time detection of viral particles using laminate based active and passive cartridge configurations. Here, we present a new concept for low-cost microfluidic integration of the sensor chips into compact cartridges through utilization of readily available Si fabrication technologies. This new cartridge configuration allows simultaneous detection of individual virus binding events on a 9-spot microarray, and will provide the needed simplicity and robustness for routine real-time operation for discrete detection of viral particles in a multiplex format.
- 14 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 23 (2) , 394-403
Robust Visualization and Discrimination of Nanoparticles by Interferometric Imaging
Single-molecule and single-nanoparticle biosensors are a growing frontier in diagnostics. Digital biosensors are those which enumerate all specifically immobilized biomolecules or biological nanoparticles, and thereby achieve limits of detection usually beyond the reach of ensemble measurements. Here, we review modern optical techniques for single nanoparticle detection and describe the single-particle interferometric reflectance imaging sensor (SP-IRIS). We present challenges associated with reliably detecting faint nanoparticles with SP-IRIS, and describe image acquisition processes and software modifications to address them. Specifically, we describe an image acquisition processing method for the discrimination and accurate counting of nanoparticles that greatly reduce both the number of false positives and false negatives. These engineering improvements are critical steps in the translation of SP-IRIS toward applications in medical diagnostics.
- 14 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 23 (2) , 394-403
Robust Visualization and Discrimination of Nanoparticles by Interferometric Imaging
Single-molecule and single-nanoparticle biosensors are a growing frontier in diagnostics. Digital biosensors are those which enumerate all specifically immobilized biomolecules or biological nanoparticles, and thereby achieve limits of detection usually beyond the reach of ensemble measurements. Here, we review modern optical techniques for single nanoparticle detection and describe the single-particle interferometric reflectance imaging sensor (SP-IRIS). We present challenges associated with reliably detecting faint nanoparticles with SP-IRIS, and describe image acquisition processes and software modifications to address them. Specifically, we describe an image acquisition processing method for the discrimination and accurate counting of nanoparticles that greatly reduce both the number of false positives and false negatives. These engineering improvements are critical steps in the translation of SP-IRIS toward applications in medical diagnostics.
- 17 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (12) , 3276-3283
An Interferometric Reflectance Imaging Sensor for Point of Care Viral Diagnostics
The use of in vitro diagnostic devices is transitioning from the laboratory to the primary care setting to address early disease detection needs. Time critical viral diagnoses are often made without support due to the experimental time required in today's standard tests. Available rapid point of care (POC) viral tests are less reliable, requiring a follow-on confirmatory test before conclusions can be drawn. The development of a reliable POC viral test for the primary care setting would decrease the time for diagnosis leading to a lower chance of transmission and improve recovery. The single particle interferometric reflectance imaging sensor (SP-IRIS) has been shown to be a sensitive and specific-detection platform in serum and whole blood. This paper presents a step towards a POC viral assay through a SP-IRIS prototype with automated data acquisition and analysis and a simple, easy-to-use software interface. Decreasing operation complexity highlights the potential of SP-IRIS as a sensitive and specific POC diagnostic tool. With the integration of a microfluidic cartridge, this automated instrument will allow an untrained user to run a sample-to-answer viral assay in the POC setting.
- 17 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (12) , 3276-3283
An Interferometric Reflectance Imaging Sensor for Point of Care Viral Diagnostics
The use of in vitro diagnostic devices is transitioning from the laboratory to the primary care setting to address early disease detection needs. Time critical viral diagnoses are often made without support due to the experimental time required in today's standard tests. Available rapid point of care (POC) viral tests are less reliable, requiring a follow-on confirmatory test before conclusions can be drawn. The development of a reliable POC viral test for the primary care setting would decrease the time for diagnosis leading to a lower chance of transmission and improve recovery. The single particle interferometric reflectance imaging sensor (SP-IRIS) has been shown to be a sensitive and specific-detection platform in serum and whole blood. This paper presents a step towards a POC viral assay through a SP-IRIS prototype with automated data acquisition and analysis and a simple, easy-to-use software interface. Decreasing operation complexity highlights the potential of SP-IRIS as a sensitive and specific POC diagnostic tool. With the integration of a microfluidic cartridge, this automated instrument will allow an untrained user to run a sample-to-answer viral assay in the POC setting.