Ahmet Tuysuzoglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmet Tuysuzoglu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Alexander P. Reddington
Department of Electrical and Computer Engineering, Boston University, Boston, MA, USA
1 shared publication - Carlos A. Lopez
Department of Electrical and Computer Engineering, Boston University, Boston, MA, USA
1 shared publication - David S. Freedman
Department of Electrical and Computer Engineering, Boston University, 8 Saint Mary’s St, Boston 02215, MA, USA
1 shared publication - George G. Daaboul
Department of Biomedical Engineering , Boston University, Boston, MA, USA
1 shared publication - Helen Fawcett
Department of Mechanical Engineering , Boston University, Boston, MA, USA
1 shared publication - Jacob T. Trueb
Mechanical Engineering, Boston University, Boston, Massachusetts United States
1 shared publication
Latest Publications
- 17 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (12) , 3276-3283
An Interferometric Reflectance Imaging Sensor for Point of Care Viral Diagnostics
The use of in vitro diagnostic devices is transitioning from the laboratory to the primary care setting to address early disease detection needs. Time critical viral diagnoses are often made without support due to the experimental time required in today's standard tests. Available rapid point of care (POC) viral tests are less reliable, requiring a follow-on confirmatory test before conclusions can be drawn. The development of a reliable POC viral test for the primary care setting would decrease the time for diagnosis leading to a lower chance of transmission and improve recovery. The single particle interferometric reflectance imaging sensor (SP-IRIS) has been shown to be a sensitive and specific-detection platform in serum and whole blood. This paper presents a step towards a POC viral assay through a SP-IRIS prototype with automated data acquisition and analysis and a simple, easy-to-use software interface. Decreasing operation complexity highlights the potential of SP-IRIS as a sensitive and specific POC diagnostic tool. With the integration of a microfluidic cartridge, this automated instrument will allow an untrained user to run a sample-to-answer viral assay in the POC setting.
- 17 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (12) , 3276-3283
An Interferometric Reflectance Imaging Sensor for Point of Care Viral Diagnostics
The use of in vitro diagnostic devices is transitioning from the laboratory to the primary care setting to address early disease detection needs. Time critical viral diagnoses are often made without support due to the experimental time required in today's standard tests. Available rapid point of care (POC) viral tests are less reliable, requiring a follow-on confirmatory test before conclusions can be drawn. The development of a reliable POC viral test for the primary care setting would decrease the time for diagnosis leading to a lower chance of transmission and improve recovery. The single particle interferometric reflectance imaging sensor (SP-IRIS) has been shown to be a sensitive and specific-detection platform in serum and whole blood. This paper presents a step towards a POC viral assay through a SP-IRIS prototype with automated data acquisition and analysis and a simple, easy-to-use software interface. Decreasing operation complexity highlights the potential of SP-IRIS as a sensitive and specific POC diagnostic tool. With the integration of a microfluidic cartridge, this automated instrument will allow an untrained user to run a sample-to-answer viral assay in the POC setting.
- 1 February 2012
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 131 (2) , 1271-1281
Sparsity driven ultrasound imaging
An image formation framework for ultrasound imaging from synthetic transducer arrays based on sparsity-driven regularization functionals using single-frequency Fourier domain data is proposed. The framework involves the use of a physics-based forward model of the ultrasound observation process, the formulation of image formation as the solution of an associated optimization problem, and the solution of that problem through efficient numerical algorithms. The sparsity-driven, model-based approach estimates a complex-valued reflectivity field and preserves physical features in the scene while suppressing spurious artifacts. It also provides robust reconstructions in the case of sparse and reduced observation apertures. The effectiveness of the proposed imaging strategy is demonstrated using experimental data.
- 1 February 2012
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 131 (2) , 1271-1281
Sparsity driven ultrasound imaging
An image formation framework for ultrasound imaging from synthetic transducer arrays based on sparsity-driven regularization functionals using single-frequency Fourier domain data is proposed. The framework involves the use of a physics-based forward model of the ultrasound observation process, the formulation of image formation as the solution of an associated optimization problem, and the solution of that problem through efficient numerical algorithms. The sparsity-driven, model-based approach estimates a complex-valued reflectivity field and preserves physical features in the scene while suppressing spurious artifacts. It also provides robust reconstructions in the case of sparse and reduced observation apertures. The effectiveness of the proposed imaging strategy is demonstrated using experimental data.