Wolfhard Semmler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wolfhard Semmler has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Cosimo D'Andrea
Center for Nanoscience and Technology, Istituto Italiano di Tecnologia, Via Rubattino 81, 20134 Milano, Italy
2 shared publications - Gianluca Valentini
Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
2 shared publications - Ralf B. Schulz
Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
2 shared publications - Rinaldo Cubeddu
Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
2 shared publications Joerg Peter
1 shared publication- Jörg Peter
German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
1 shared publication
Latest Publications
- 1 January 2008
- Published by Springer Nature
- p. 3-22
Fundamentals of Optical Imaging
Optical imaging techniques offer simplistic while highly sensitive modalities for molecular imaging research. In this chapter, the major instrumental necessities for microscopic and whole-animal imaging techniques are introduced. Subsequently, the resulting imaging modalities using visible or near-infrared light are presented and discussed. The aim is to show the current capabilities and application fields of optics.
- 1 January 2008
- Published by Springer Nature
- p. 3-22
Fundamentals of Optical Imaging
Optical imaging techniques offer simplistic while highly sensitive modalities for molecular imaging research. In this chapter, the major instrumental necessities for microscopic and whole-animal imaging techniques are introduced. Subsequently, the resulting imaging modalities using visible or near-infrared light are presented and discussed. The aim is to show the current capabilities and application fields of optics.
- Open Access
- 1 January 2007
- Published by Optica Publishing Group
- p. 6626_19
Applying Time-Dependent Data for Fluorescence Tomography
Can time-resolved, high-resolution data as acquired by an intensified gated CCD camera (ICCD) aid in the tomographic reconstruction of fluorescence concentration? Usually it is argued that fluorescence is a linear process and thus does not require non-linear, time-dependent reconstructions algorithms, unless absorption and scattering coefficients need to be determined as well. Furthermore, the acquisition of a number of time frames is usually prohibitive for fluorescence measurements, at least in small animals, due to the increased total measurement time. On the other hand, it is obvious that diffusion is less pronounced in images at early gates, due to selective imaging of photons of lower scatter order. This will be the case also for photons emitted by fluorescent sources. Early-gated imaging might increase the contrast in acquired images and could possibly improve fluorescence localization. Herein, we present early gated fluorescence images obtained from phantoms and compare them to continuously acquired data. Increased contrast between background and signal maximum can be observed in time-gated images as compared to continuous data. To make use of the properties exhibited by early gated frames, it is necessary to use a modified reconstruction algorithm. We propose a variant of the well-known Born approximation to the diffusion equation that allows to take into account single time frames. The system matrix for the time-dependent Born approach is more complex to calculate, however the complexity of the actual inverse problem (and the acquisition times) of single-frame reconstructions remains the same as compared to continuous mode.
- 1 January 2007
- Published by Optica Publishing Group
- p. 6626_19
Open AccessApplying Time-Dependent Data for Fluorescence Tomography
Can time-resolved, high-resolution data as acquired by an intensified gated CCD camera (ICCD) aid in the tomographic reconstruction of fluorescence concentration? Usually it is argued that fluorescence is a linear process and thus does not require non-linear, time-dependent reconstructions algorithms, unless absorption and scattering coefficients need to be determined as well. Furthermore, the acquisition of a number of time frames is usually prohibitive for fluorescence measurements, at least in small animals, due to the increased total measurement time. On the other hand, it is obvious that diffusion is less pronounced in images at early gates, due to selective imaging of photons of lower scatter order. This will be the case also for photons emitted by fluorescent sources. Early-gated imaging might increase the contrast in acquired images and could possibly improve fluorescence localization. Herein, we present early gated fluorescence images obtained from phantoms and compare them to continuously acquired data. Increased contrast between background and signal maximum can be observed in time-gated images as compared to continuous data. To make use of the properties exhibited by early gated frames, it is necessary to use a modified reconstruction algorithm. We propose a variant of the well-known Born approximation to the diffusion equation that allows to take into account single time frames. The system matrix for the time-dependent Born approach is more complex to calculate, however the complexity of the actual inverse problem (and the acquisition times) of single-frame reconstructions remains the same as compared to continuous mode.
- 1 January 2005
- Published by Optica Publishing Group
- p. ThA5
Quantifiability and Image Quality in Noncontact Fluorescence Tomography
Non-contact detection in fluorescence tomography enables image acquisiton without matching fluids or fiber optics. We present experimental results showing quantifiability of noncontact measurements as well as improvements in image quality between conventional and non-contact detection.
- 1 January 2005
- Published by Optica Publishing Group
- p. ThA5
Quantifiability and Image Quality in Noncontact Fluorescence Tomography
Non-contact detection in fluorescence tomography enables image acquisiton without matching fluids or fiber optics. We present experimental results showing quantifiability of noncontact measurements as well as improvements in image quality between conventional and non-contact detection.
- 1 January 2005
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 15 (3) , 177-186
Grundlagen optischer und fluoreszenzgestützter Tomographie in diffusen Medien
- 1 January 2005
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 15 (3) , 177-186
Grundlagen optischer und fluoreszenzgestützter Tomographie in diffusen Medien