Guoxing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Guoxing Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Mohanasankar Sivaprakasam
Indian Institute of Technology Madras
2 shared publications - Wentai Liu
Electrical Engineering Department, University of California, Santa Cruz, Santa Cruz, CA 95064 USA. phone: 831-459-5766
2 shared publications A. Kendir
Dept. of Electr. & Comput. Eng., North Carolina State Univ., Raleigh, NC, USA
1 shared publicationB. Pundi
Dept. of Electr. & Comput. Eng., North Carolina State Univ., Raleigh, NC, USA
1 shared publication- James David Weiland
University of Michigan, Ann Arbor, USA
1 shared publication - Mark S. Humayun
Doheny Eye Institute, Department of Ophthalmology, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
1 shared publication
Latest Publications
- 23 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 6 (3) , 208-215
Analysis of Dual Band Power and Data Telemetry for Biomedical Implants
Inductive coupling is commonly used for wireless power and data transfer in biomedical telemetry systems. To increase data bandwidth while maintaining power transfer efficiency, a multiband telemetry system transmitting power and data using different frequencies has been adopted. However, the power link and data link interact with each other, complicating the operation of both power and data transmission. In this paper, we demonstrate that to achieve high performance data transmission, the cross-coupling between the power coils and data coils have to be taken into consideration. Design equations have been derived and shown that the signal to noise (interference) ratio could be significantly reduced and the resulting data transmission could fail if only the data link coupling is optimized without considering the cross-coupling between the power link and the data link. Design examples have been constructed to demonstrate that there could be more than 30 dB difference in the signal to noise ratio. The analysis has been verified with simulation and measurement results.
- 23 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 6 (3) , 208-215
Analysis of Dual Band Power and Data Telemetry for Biomedical Implants
Inductive coupling is commonly used for wireless power and data transfer in biomedical telemetry systems. To increase data bandwidth while maintaining power transfer efficiency, a multiband telemetry system transmitting power and data using different frequencies has been adopted. However, the power link and data link interact with each other, complicating the operation of both power and data transmission. In this paper, we demonstrate that to achieve high performance data transmission, the cross-coupling between the power coils and data coils have to be taken into consideration. Design equations have been derived and shown that the signal to noise (interference) ratio could be significantly reduced and the resulting data transmission could fail if only the data link coupling is optimized without considering the cross-coupling between the power link and the data link. Design examples have been constructed to demonstrate that there could be more than 30 dB difference in the signal to noise ratio. The analysis has been verified with simulation and measurement results.
- 27 July 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2743
Power Supply Topologies for Biphasic Stimulation in Inductively Powered Implants
Biphasic stimulation is commonly used for electrical stimulation of tissue in many implants. A dual voltage scheme is often used for the operation of the stimulus circuitry. Due to the advantages of wireless power transmission, an inductive link is used to recover the transmitted power and generate these voltages. This paper identifies the problem of additional power dissipation in the implant when the traditional rectifier topology with one diode is used. A dual diode topology is proposed which reduces the power dissipated in the implant by half. A detailed analysis for both topologies is done through derivation of expressions for the power losses on the primary and secondary coils. A comparison of single diode and dual diode topologies is presented under different conditions and inferences are drawn that can be used as design guidelines.
- 27 July 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2743
Power Supply Topologies for Biphasic Stimulation in Inductively Powered Implants
Biphasic stimulation is commonly used for electrical stimulation of tissue in many implants. A dual voltage scheme is often used for the operation of the stimulus circuitry. Due to the advantages of wireless power transmission, an inductive link is used to recover the transmitted power and generate these voltages. This paper identifies the problem of additional power dissipation in the implant when the traditional rectifier topology with one diode is used. A dual diode topology is proposed which reduces the power dissipated in the implant by half. A detailed analysis for both topologies is done through derivation of expressions for the power losses on the primary and secondary coils. A comparison of single diode and dual diode topologies is presented under different conditions and inferences are drawn that can be used as design guidelines.
- 4 November 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
A smart bi-directional telemetry unit for retinal prosthetic device
This paper describes a smart bi-directional telemetry unit for an implantable retinal prosthetic device. The system is designed to deliver 250 mW to the intra-ocular unit via an inductive link and provide wireless communication capability. A novel dual frequency carrier approach is used to optimize the power link for maximum transfer efficiency and the forward telemetry for high data rates. The power link uses a smart feedback system via reverse telemetry to compensate for instantaneous changes in power level due to coil misalignment and load variations. The system is optimized to minimize the power losses in the analog front-end of the intraocular unit while ensuring proper device operation. Preliminary results are shown in AMI 1.6 /spl mu/m bulk CMOS process for the reverse telemetry and power feedback system.
- 4 November 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
A smart bi-directional telemetry unit for retinal prosthetic device
This paper describes a smart bi-directional telemetry unit for an implantable retinal prosthetic device. The system is designed to deliver 250 mW to the intra-ocular unit via an inductive link and provide wireless communication capability. A novel dual frequency carrier approach is used to optimize the power link for maximum transfer efficiency and the forward telemetry for high data rates. The power link uses a smart feedback system via reverse telemetry to compensate for instantaneous changes in power level due to coil misalignment and load variations. The system is optimized to minimize the power losses in the analog front-end of the intraocular unit while ensuring proper device operation. Preliminary results are shown in AMI 1.6 /spl mu/m bulk CMOS process for the reverse telemetry and power feedback system.