Achille Mileto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Achille Mileto has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Daniele Marin
Department of Radiology, Duke University Medical Center, Box 3808 Erwin Rd, Durham, NC 27710
4 shared publicationsRendon C. Nelson
Department of Radiology, Duke University Medical Center, Box 3808 Erwin Rd, Durham, NC 27710
3 shared publicationsAndrew Barina
From the Department of Radiology (A.M., A.B., D.M., S.S.S., R.C.N.) and Carl E. Ravin Advanced Imaging Laboratories (K.R.C., J.M.W.), Duke University Medical Center, Box 3808, Erwin Rd, Durham, NC 27710
1 shared publicationCaecilia S. Reiner
Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
1 shared publicationDaniel T. Boll
1 shared publication- Daniel T. Boll
Department of Radiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
1 shared publication
Latest Publications
- 1 August 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (2) , 310-320
Adoption of Splenic Enhancement to Time and Trigger the Late Hepatic Arterial Phase During MDCT of the Liver: Proof of Concept and Clinical Feasibility
OBJECTIVE. The purpose of this study was to prospectively investigate the clinical feasibility of adopting splenic enhancement for timing and triggering the acquisition of late hepatic arterial phase images during multiphasic liver MDCT for assessment of hypervascular tumors. SUBJECTS AND METHODS. Forty-eight patients (33 men, 15 women; median age, 59 years; chronic liver disease, 23 patients; portal venous hypertension, 17 patients) with a total of 81 hypervascular liver tumors underwent liver MDCT by random assignment to one of two scanning protocols. Scanning delay for the late hepatic arterial phase was determined by assessment of time-to-peak splenic enhancement (splenic-triggering protocol) or aortic enhancement (aortic-triggering protocol). Acquisition timing, vascular attenuation, liver attenuation and homogeneity, signal-to-noise ratio, tumor-to-liver contrast, and tumor-to-liver contrast-to-noise ratio were compared. Two blinded independent observers used Likert scales to score timing adequacy (...
- 1 August 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (2) , 310-320
Adoption of Splenic Enhancement to Time and Trigger the Late Hepatic Arterial Phase During MDCT of the Liver: Proof of Concept and Clinical Feasibility
OBJECTIVE. The purpose of this study was to prospectively investigate the clinical feasibility of adopting splenic enhancement for timing and triggering the acquisition of late hepatic arterial phase images during multiphasic liver MDCT for assessment of hypervascular tumors. SUBJECTS AND METHODS. Forty-eight patients (33 men, 15 women; median age, 59 years; chronic liver disease, 23 patients; portal venous hypertension, 17 patients) with a total of 81 hypervascular liver tumors underwent liver MDCT by random assignment to one of two scanning protocols. Scanning delay for the late hepatic arterial phase was determined by assessment of time-to-peak splenic enhancement (splenic-triggering protocol) or aortic enhancement (aortic-triggering protocol). Acquisition timing, vascular attenuation, liver attenuation and homogeneity, signal-to-noise ratio, tumor-to-liver contrast, and tumor-to-liver contrast-to-noise ratio were compared. Two blinded independent observers used Likert scales to score timing adequacy (...
- 1 July 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 280 (1) , 230-236
Regional Mapping of Aortic Wall Stress by Using Deformable, Motion-coherent Modeling based on Electrocardiography-gated Multidetector CT Angiography: Feasibility Study
To investigate the feasibility of deformable, motion-coherent modeling based on electrocardiography-gated multidetector computed tomographic (CT) angiography of the thoracic aorta and to evaluate whether quantifiable information on aortic wall stress as a function of patient-specific cardiovascular parameters can be gained. For this institutional review board–approved, HIPAA-compliant study, thoracic electrocardiography-gated dual-source multidetector CT angiographic images were used from 250 prospectively enrolled patients (150 men, 100 women; mean age, 79 years). On reconstructed 50-phase CT angiographic images, aortic strain and deformation were determined at seven cardiac and aortic locations. One-way analysis of variance was used by assessing the magnitude for longitudinal and axial strain and axial deformation, as well as time-resolved peak and maxima count for longitudinal strain and axial deformation. Interdependencies between aortic strain and deformation with extracted hemodynamic parameters were evaluated. With increasing heart rates, there was a significant decrease in longitudinal strain (P = .009, R2 = 0.95) and a decrease in the number of longitudinal strain peaks (P < .001, R2 = 0.79); however, a significant increase in axial deformation (P < .001, R2 = 0.31) and axial strain (P = .009, R2 = 0.61) was observed. Increasing aortic blood velocity led to increased longitudinal strain (P = .018, R2 = 0.42) and longitudinal strain peak counts (P = .011, R2 = 0.48). Pronounced motion in the longitudinal direction limited motion in the axial plane (P < .019, R2 = 0.29–0.31). The results of this study render a clinical basis and provide proof of principle for the use of deformable, motion-coherent modeling to provide quantitative information on physiological motion of the aorta under various hemodynamic circumstances. © RSNA, 2016 Online supplemental material is available for this article.
- 1 July 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 280 (1) , 230-236
Regional Mapping of Aortic Wall Stress by Using Deformable, Motion-coherent Modeling based on Electrocardiography-gated Multidetector CT Angiography: Feasibility Study
To investigate the feasibility of deformable, motion-coherent modeling based on electrocardiography-gated multidetector computed tomographic (CT) angiography of the thoracic aorta and to evaluate whether quantifiable information on aortic wall stress as a function of patient-specific cardiovascular parameters can be gained. For this institutional review board–approved, HIPAA-compliant study, thoracic electrocardiography-gated dual-source multidetector CT angiographic images were used from 250 prospectively enrolled patients (150 men, 100 women; mean age, 79 years). On reconstructed 50-phase CT angiographic images, aortic strain and deformation were determined at seven cardiac and aortic locations. One-way analysis of variance was used by assessing the magnitude for longitudinal and axial strain and axial deformation, as well as time-resolved peak and maxima count for longitudinal strain and axial deformation. Interdependencies between aortic strain and deformation with extracted hemodynamic parameters were evaluated. With increasing heart rates, there was a significant decrease in longitudinal strain (P = .009, R2 = 0.95) and a decrease in the number of longitudinal strain peaks (P < .001, R2 = 0.79); however, a significant increase in axial deformation (P < .001, R2 = 0.31) and axial strain (P = .009, R2 = 0.61) was observed. Increasing aortic blood velocity led to increased longitudinal strain (P = .018, R2 = 0.42) and longitudinal strain peak counts (P = .011, R2 = 0.48). Pronounced motion in the longitudinal direction limited motion in the axial plane (P < .019, R2 = 0.29–0.31). The results of this study render a clinical basis and provide proof of principle for the use of deformable, motion-coherent modeling to provide quantitative information on physiological motion of the aorta under various hemodynamic circumstances. © RSNA, 2016 Online supplemental material is available for this article.
- 1 April 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 279 (1) , 269-277
Virtual Monochromatic Images from Dual-Energy Multidetector CT: Variance in CT Numbers from the Same Lesion between Single-Source Projection-based and Dual-Source Image-based Implementations
The results of our phantom investigation suggest that single-source projection-based and dual-source image-based dual energy hardware implementations produce significant differences in virtual monochromatic CT numbers from the same iodine-containing lesion. PurposeTo determine the variance in virtual monochromatic computed tomography (CT) numbers from the same lesion, comparing the two clinically available dual-energy multidetector CT hardware implementations (single-source projection-based and dual-source image-based), in a phantom-based simulated abdominal environment.Materials and MethodsThis phantom-based study was exempt from institutional review board oversight. Polyethylene terephthalate spheres (15 and 18 mm) with two iodine-to-saline dilutions (0.8 and 1.2 mg of iodine per millilliter) were serially suspended in a cylindrical polypropylene bottle filled with diluted iodinated contrast material. The bottle was placed into a 36-cm-wide torso-shaped water phantom simulating the abdomen of a medium-sized patient. Dual-energy (80/140 kVp) and single-energy (100 and 120 kVp) scans were obtained with single-source and dual-source multidetector CT implementations. Virtual monochromatic images were reconstructed at energy levels of 40–140 keV (in 10-keV incr...
- 1 April 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 279 (1) , 269-277
Virtual Monochromatic Images from Dual-Energy Multidetector CT: Variance in CT Numbers from the Same Lesion between Single-Source Projection-based and Dual-Source Image-based Implementations
The results of our phantom investigation suggest that single-source projection-based and dual-source image-based dual energy hardware implementations produce significant differences in virtual monochromatic CT numbers from the same iodine-containing lesion. PurposeTo determine the variance in virtual monochromatic computed tomography (CT) numbers from the same lesion, comparing the two clinically available dual-energy multidetector CT hardware implementations (single-source projection-based and dual-source image-based), in a phantom-based simulated abdominal environment.Materials and MethodsThis phantom-based study was exempt from institutional review board oversight. Polyethylene terephthalate spheres (15 and 18 mm) with two iodine-to-saline dilutions (0.8 and 1.2 mg of iodine per millilliter) were serially suspended in a cylindrical polypropylene bottle filled with diluted iodinated contrast material. The bottle was placed into a 36-cm-wide torso-shaped water phantom simulating the abdomen of a medium-sized patient. Dual-energy (80/140 kVp) and single-energy (100 and 120 kVp) scans were obtained with single-source and dual-source multidetector CT implementations. Virtual monochromatic images were reconstructed at energy levels of 40–140 keV (in 10-keV incr...
- 22 January 2016
- Published by Springer Nature in European Radiology
- Vol. 26 (10) , 3677-3690
Imaging the renal lesion with dual-energy multidetector CT and multi-energy applications in clinical practice: what can it truly do for you?
Many fortuitously detected renal lesions are incompletely characterised at traditional MDCT imaging, thus posing daily challenges to radiologists and referring physicians. There is burgeoning evidence that dual-energy MDCT and multi-energy applications provide an added value over traditional MDCT imaging in renal lesion characterisation and throughput. This special report gives a vendor-neutral outlook on technical essentials, recommended protocols, high-yield clinical opportunities and reviews radiation dose aspects of dual-energy MDCT imaging and multi-energy applications in renal lesions. In addition to a guide on interpretative traps and emerging problems, we provide an update on new, potential imaging horizons. Dual-energy MDCT and multi-energy applications can facilitate the imaging interpretation and throughput of renal lesions. Conjointly with capitalisation on the benefits, familiarity with dual- and multi-energy data sets as well as continuous scrutiny of interpretative traps can be the keys to the successful implementation and enhanced clinical acceptance of this powerful technique in the imaging community. Continuous advances in hardware and computer interfaces are expected to pave the way for the further expansion of the application spectrum. • Optimal protocols must be adopted for leveraging dual-energy benefits in renal imaging. • Virtual monochromatic imaging can overcome renal cyst pseudoenhancement. • Iodine maps help to interpret renal lesions incompletely characterised at traditional MDCT. • Interpretative traps need to be weighed-up in dual-energy renal lesions imaging. • Technical advances are expanding the dual-energy applications spectrum for renal lesions imaging.
- 22 January 2016
- Published by Springer Nature in European Radiology
- Vol. 26 (10) , 3677-3690
Imaging the renal lesion with dual-energy multidetector CT and multi-energy applications in clinical practice: what can it truly do for you?
Many fortuitously detected renal lesions are incompletely characterised at traditional MDCT imaging, thus posing daily challenges to radiologists and referring physicians. There is burgeoning evidence that dual-energy MDCT and multi-energy applications provide an added value over traditional MDCT imaging in renal lesion characterisation and throughput. This special report gives a vendor-neutral outlook on technical essentials, recommended protocols, high-yield clinical opportunities and reviews radiation dose aspects of dual-energy MDCT imaging and multi-energy applications in renal lesions. In addition to a guide on interpretative traps and emerging problems, we provide an update on new, potential imaging horizons. Dual-energy MDCT and multi-energy applications can facilitate the imaging interpretation and throughput of renal lesions. Conjointly with capitalisation on the benefits, familiarity with dual- and multi-energy data sets as well as continuous scrutiny of interpretative traps can be the keys to the successful implementation and enhanced clinical acceptance of this powerful technique in the imaging community. Continuous advances in hardware and computer interfaces are expected to pave the way for the further expansion of the application spectrum. • Optimal protocols must be adopted for leveraging dual-energy benefits in renal imaging. • Virtual monochromatic imaging can overcome renal cyst pseudoenhancement. • Iodine maps help to interpret renal lesions incompletely characterised at traditional MDCT. • Interpretative traps need to be weighed-up in dual-energy renal lesions imaging. • Technical advances are expanding the dual-energy applications spectrum for renal lesions imaging.
- 1 January 2015
- Published by Springer Nature
- p. 107-122
Dual Energy CT in Renal Tumors
- 4 October 2013
- Published by Springer Nature in European Radiology
- Vol. 24 (2) , 353-362
Dual energy MDCT assessment of renal lesions: an overview
- 4 October 2013
- Published by Springer Nature in European Radiology
- Vol. 24 (2) , 353-362
Dual energy MDCT assessment of renal lesions: an overview