HNHassan Ali Nedaie

Hassan Ali Nedaie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hassan Ali Nedaie has a total of 90 co-authors. Here are the top co-authors by number of shared publications:

  • Nooshin Banaee

    Medical Radiation Research Center, Central Tehran Branch, Islamic Azad University, Tehran, Iran

    9 shared publications
  • Ghazale Geraily

    Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran

    4 shared publications
  • Somayeh Gholami

    PhD, Radiation Oncology Research Center, Cancer institute, Tehran University of Medical Sciences, Tehran, Iran

    4 shared publications
  • Francesco Longo

    University of Trieste, Piazzale Europa, Trieste, Friuli-Venezia Giulia, 34127 , ITALY

    3 shared publications
  • Mahbod Esfahani

    Department of Medical Physics and Medical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran

    3 shared publications
  • Nooshin Banaee

    Department of Nuclear Engineering, C T C, Islamic Azad University, Tehran, Iran

    3 shared publications

Latest Publications

  • Enhanced radiosensitization using TiO 2 and HfO 2 nanoparticles in Gamma Knife radiosurgery: insights from GEANT4 and GEANT4-DNA simulations

    by Mehrafrouz Soleymani, Nooshin Banaee, Hassan Ali Nedaie, Sahar Rajabi Moghadam, Seyed Rabi Mahdavi

    This study employs GEANT4 and GEANT4-DNA Monte Carlo simulations to evaluate the radiosensitization effects of titanium dioxide (TiO 2 ) and hafnium dioxide (HfO 2 ) nanoparticles (NPs) in Gamma Knife ICON radiosurgery. A multi scale simulation was performed to calculate dose enhancement factor (DEF) as well as DNA damage enhancement factor (DDEF) due to the presence of 20, 53, and 106 mg ml −1 TiO 2 and HfO 2 NPs with a size of 30, 65, or 100 nm. Increasing NP concentration and size resulted in higher DEF and DDEF, with HfO 2 outperforming TiO 2 due to its higher density and effective atomic number. Increasing NP concentration from 20 to 106 mg ml −1 raised the DEF by up to 10.5% for HfO 2 and 6.82% for TiO 2 , while increasing NP diameter from 30 to 100 nm resulted in DEF increases of up to 3.10% and 2.10%, respectively. DNA damage yields (single- and double-strand breaks) followed similar trends, corroborating the enhanced radiobiological impact. Cell survival curves (obtained by Two-Lesion Kinetic model) demonstrated increased radiosensitization with higher NP concentration and size, particularly for HfO 2 . These findings suggest that HfO 2 NPs represent a promising high- Z sensitizer for enhancing therapeutic efficacy in radiosurgery, warranting further comparative studies against established sensitizers such as gold.

  • Open Access

    Dosimetric Analysis of BEBIG 60Co and Flexisource 192Ir HDR Brachytherapy Sources using Geant4 Simulation

    by Naser Hussein Judran Alrikabi, Hassan Ali Nedaei, Nooshin Banaee

    Background: This study validates the precision of dosimetric constraints for the BEBIG 60Co and Flexisource 192Ir Brachytherapy Sources using the Geant4 Monte Carlo code, commonly applied in clinical brachytherapy. Objective: The current study aimed to assess the effects of tissue heterogeneities on dosimetry by evaluating key parameters for the BEBIG 60Co and Flexisource 192Ir Brachytherapy Sources. Material and Methods: In this simulation study, the geometries of the BEBIG 60Co and 192Ir Flexi-sources were modeled within a water sphere. Key dosimetric parameters, including air kerma strength (SkS), dose rate constant (λ), radial dose function (g(r)), and anisotropy function (F(r,θ)) were calculated according to TG-43 and ESTRO standards. Results: The dose rate constants for BEBIG 60Co and 192Ir Flexi-sources were 1.079 cGy/h ±0.008 and 1.099 cGy/h ±0.01, respectively, with deviations of 0.73% and 0.91% from reference values. The radial dose function showed a maximum deviation of less than 2% at 15 cm for both sources, indicating strong agreement with the reference data. Conclusion: Geant4 Monte Carlo simulations provide precise validation of BEBIG 60Co and 192Ir Flexi-sources. The findings suggest that 60Co offers a dosimetric advantage by reducing exposure to nearby organs while effectively reaching distant tissues, potentially enhancing treatment precision and safety in clinical brachytherapy.

  • Open Access

    Margins of Planning Target Volume and Set-up Errors based on Megavoltage Cone-Beam CT Image Guided Radiotherapy with Helical Tomotherapy: Importance of Automatic Registration Plus Manual Registration

    by Danial Seifi Makrani, Nooshin Banaee, Ghazale Geraily, Hassan Ali Nedaie, Alireza Khorrami Moghaddam, Hussam Hameed Jassim

    Background: Helical Tomotherapy (HT) enables daily verification of patient positioning using Megavoltage Computed Tomography (MVCT) during each treatment session. Objective: The present study aimed to investigate the effects of Automatic Registration (AR) compared to a combination of Automatic and Manual Registration (AR+MR) on setup errors. Additionally, the study aimed to determine the corresponding Margins of the Planning Target Volume (MPTV). Material and Methods: In this experimental study, a total of 1513 daily MVCT scans were analyzed from September 2020 to January 2024, which were obtained from 71 patients diagnosed with Head and Neck (HN), cervical, and gastrointestinal cancer. The scans were registered with the planning CT to determine the setup errors of the patients. The analysis compares the setup errors between the AR and the AR+MR techniques in translational (X, Y, and Z axes) and rotational directions (RX, RY, and RZ). Additionally, the study calculated the MPTV. Results: In the AR and AR+MR techniques, the translational setup errors were significantly different in the Z-axis for HN patients. For cervical cancer patients, AR and AR+MR exhibited significantly different translational errors across all axes. Furthermore, they also had notable differences in the Y and Z-axis translational errors for Gastro-Intestinal (GI) patients. Regarding the rotational setup errors, a substantial difference was observed in the Z-axis translational error for cervical cancer patients, and in the Y and Z-axes for GI patients. Conclusion: Human assessment after automatic registration helps ensure that the registration is clinically appropriate, especially in circumstances involving deformable patient anatomy.

  • Open Access

    Evaluation of Capability and Relationship of Different Radiobiological Endpoints for Radiosensitivity Prediction in Human Tumor Cell Lines Compared with Clonogenic Survival

    by Fatemeh Pakniyat, Hassan Ali Nedaee, Hossein Mozdarani, Aziz Mahmoudzadeh, Somayeh Gholami

    Background: Establishing a predictive assay of radiosensitivity (as an appropriate, practical and cost-effective method) has been challenging. Objective: The purpose of this study is to evaluate the capability and relationship of various endpoints, including GammaH2AX, micronuclei; and apoptosis in determining the human tumor cell lines radiosensitivities compared with clonogenic survival.Material and Methods: In an experimental in-vitro study, the response of carcinoma cell lines of HN5 and HeLa to 2 Gy of 6 MV photon beam was investigated via various assays. Results: Survival fraction at 2 Gy (SF2) of HeLa and HN5 was indicated as 0.42 ± 0.06 and 0.5 ± 0.03 respectively, proposing more radioresistance of HN5. This finding was confirmed with “2 Gy apoptosis enhancement ratio” which was 1.77 and 1.42 in HeLa and HN5. The increased levels of DNA DSBs were observed after irradiation; significant in HeLa with enhancement rate of 19.24. The micronuclei formation followed an ascending trend post irradiation; but with the least difference between two cells. Although the relationship between micronuclei and clonogenic survival was moderate (R2 = 0.35), a good correlation was observed between apoptosis and clonogenic survival (R2 = 0.71). Conclusion: The results of studied endpoints agreed with the SF2, highlighting their capabilities in radiosensitivity prediction. In terms of the enhancement ratio, gammaH2AX foci scoring could be a valid indicator of radiosensitivity but not the exact surrogate marker of survival because no correlation was observed. Moreover, considering the chief determents comprising lack of time and money, the apoptotic induction might be an appropriate indicator with the best correlation coefficient.


  • Open Access

    BEBIG 60Co HDR brachytherapy source dosimetric parameters validation using GATE Geant4-based simulation code

    by Musa Joya, Hassan Ali Nedaie, Ghazale Geraily, Mahdi Ghorbani, Peyman Sheikhzadeh, Mahmud Naraqi Arani


  • Synthesis and evaluation of thermoluminescence properties of ZrO2:Mg for radiotherapy dosimetry

    by Asieh Amarlou, Kheirollah Mohammadi, Nooshin Banaee, Hassan Ali Nedaei

    This study aimed to investigate the thermoluminescent properties of ZrO2:Mg irradiated with a 6 MV X-ray beam and its potential application in radiotherapy dosimetry. ZrO2 powder was synthesized using the sol–gel method and Mg was used as a dopant. Irradiations were performed with ZrO2:Mg chips located at the center of a 10 × 10 cm2 radiation field at a source surface distance of 100 cm, below a stack of solid water slabs, at the depth of maximum absorbed dose. The investigated characteristics of the material included linearity with radiation dose, reproducibility, accuracy, sensitivity and fading. Regarding the intrinsic difference of the samples, the glow curves of the investigated ZrO2:Mg chips exposed to 1 Gy of 6 MV X-rays exhibited three or four peaks. The ZrO2:Mg samples showed a 47% fading at 24 h after irradiation, and the reproducibility of the thermoluminescence reading of ZrO2:Mg for equal irradiation conditions was ± 21%. The thermoluminescence response of the investigated ZrO2:Mg samples to various absorbed doses from 0.5 to 2.5 Gy showed a gentle increase of the thermoluminescence intensity with increasing absorbed dose. The obtained results show that ZrO2:Mg is not an appropriate candidate for X-ray photons in radiotherapy, due to low thermoluminescence peak temperature, low reproducibility, low sensitivity to various absorbed doses and significant fading.


  • The effect of magnetic field on Linac based Stereotactic Radiosurgery dosimetric parameters

    by Hassan Ali Nedaie, Somayeh Gholami, Francesco Longo, Nooshin Banaee, Mohssen Hassani, Arman Sarfehnia, G Pang

    Objective : MR-linac machines are being developed for image-guided radiation therapy but the magnetic field of such machines could affect dose distributions. The purpose of this work was to evaluate the effect of a magnetic field on linac beam dosimetric parameters including penumbra for circular cones used in radiosurgery. Methods : Monte Carlo simulation was conducted for a linac machine with circular cones at 6 MV beam. A homogenous magnetic field of 1.5 T was applied transversely and parallel to the radiation beam. Percentage depth dose (PDD) and beam profiles in a water phantom with and without the magnetic field were calculated. Results : The results have shown that when the magnetic field is applied transversely, the PDDs in the water phantom differ in the buildup region and distant part of PDD curves. The beam profiles at three different depths are all significantly different from those without the magnetic field. The penumbra is greater when a magnetic field has been applied. Conclusion : Linear accelerator-based SRT and SRS use small circular cones. The beam penumbra for these cones can change in the presence of a magnetic field. The perturbation of dose distribution has been also observed in a patient plan due to the presence of a magnetic field. The results of this study show that dose distributions in the presence of a magnetic field must be considered for MR-guided radiotherapy treatments.


  • Enhanced response of radioresistant carcinoma cell line to heterogeneous dose distribution of grid; the role of high-dose bystander effect

    by Fatemeh Pakniyat, Hassan Ali Nedaie, Hossein Mozdarani, Aziz Mahmoudzadeh, Mahdieh Salimi, Robert J. Griffin, Somayeh Gholami

    The classical dogma that restricted the radiation effect to the directly irradiated cells has been challenged by the bystander effect. This off-target phenomenon which was manifested in adjacent ce...


  • Assessment of Radiation-Induced Secondary Cancer Risks In Breast Cancer Patients Treated with 3D Conformal Radiotherapy

    by Shima Mahmoudi, Nasim Kavousi, Mohssen Hassani, Mahbod Esfahani, Hassan Ali Nedaie


  • A Monte Carlo study of neutron contamination in presence of circular cones during stereotactic radiotherapy with 18 MV photon beams

    by Sareh Tajiki, Hassan Ali Nedaie, Faezeh Rahmani

    High-energy photons are being used to treat different kinds of cancer, but it may increase the rate of secondary cancers due to the neutron contamination as well as over exposing of patients and medical staffs in radiation therapy Takam, Bezak, Marcu, and Yeoh, 2011, Radiation Research, 176 , 508-520. Due to some difficulties in experimental measurements of neutron contamination, Monte Carlo method is an efficient tool to investigate dose parameters and characteristics in new techniques. The 18-MV photon beam of linac and circular cones have been simulated by MCNP5 code. Various parameters of photon and neutron including mean energy, flux, KERMA, the number of particles crossing a surface at a distance of 100 cm (SSD = 100 cm) as well as the change in photon and neutron spectrum as well as in intensity through the transmission in the circular collimators have been investigated. The results of this study show that the use of a circular collimator decreases neutron dose in the central axis, which is an advantage, but neutron contamination inducing small neutron dose is distributed all over the space. On the surface of phantom, photon dose rate is approximately equal to 3.41E7 (mGy/mA.min) for different collimators, but the neutron dose rate is 1.64E2 (mGy/ mA.min), 2.03E2 (mGy/ mA.min) and 2.52E2 (mGy/mA.min) for diameters of 12, 20 and 40 mm, respectively and it decreases by decreasing the diameter of the collimator. The neutron dose rate decreases from 9.68E7 and 9.74E7 (mGy/min.mA) for open field size 33 cm 2 and 55 cm 2 to 1.64E2 (mGy/min.mA), 2.02E2 (mGy/min.mA) and 2.52E2 (mGy/min.mA) for collimator diameter of 12 mm, 20 mm and 40 mm. It can be concluded that the use of circular collimators has an advantage of reducing neutron dose in the central axis. It should be mentioned that the off-axis neutron dose surrounding the collimator can be eliminated using an external neutron shield without perturbing the treatment field.