Toomas Parve
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Toomas Parve has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Mart Min
Tallinn University of Technology
4 shared publications - Andres Kink
SmartImplant, Ltd. Tallinn 12618, Estonia. phone: +372 5063881; fax: +372 6202151
2 shared publications - Indrek Ratsep
Department of Electronics, Tallinn University of Technology, Tallinn 19086, Estonia
2 shared publications - Mario Martínez Zarzuela
Department of Signal Theory and Communications and Telematics Engineering, University of Valladolid, Valladolid, Spain
2 shared publications - Rodney W. Salo
Member, IEEE, Basic Research Department, Guidant Corporation, St Paul, MN 55112 USA. 651-582-4034
2 shared publications - Uwe Pliquett
Institut für Bioprozess- und Analysenmeßtechnik
2 shared publications
Latest Publications
- 1 January 2013
- Vol. 189, 107-12
Wearable data acquisition system of multimodal physiological signals for personal health care.
The paper proposes a wearable multimodal data acquisition system for biological signals. The system enables logging of electrical bioimpedance signals from multiple electrodes, electrocardiographic signals (ECG), acceleration signals from multiple locations, and spirometric data from a moving object. Later it will be used to conduct field measurements for characterizing health of the object under investigation. Main goal is to acquire enough data for development, refinement, and simplification of signal processing algorithms. The system is center part of the new wearable compact data acquisition modules ZCardio. Those modules enable multichannel impedance spectroscopy by logging ECG signals and data from the spirometric sensor. Initial reference measurements were conducted. Alternatively, tests were performed using Plessey Semiconductors capacitive sensors. Acceleration signals are gathered.
- 1 January 2013
- Vol. 189, 107-12
Wearable data acquisition system of multimodal physiological signals for personal health care.
The paper proposes a wearable multimodal data acquisition system for biological signals. The system enables logging of electrical bioimpedance signals from multiple electrodes, electrocardiographic signals (ECG), acceleration signals from multiple locations, and spirometric data from a moving object. Later it will be used to conduct field measurements for characterizing health of the object under investigation. Main goal is to acquire enough data for development, refinement, and simplification of signal processing algorithms. The system is center part of the new wearable compact data acquisition modules ZCardio. Those modules enable multichannel impedance spectroscopy by logging ECG signals and data from the spirometric sensor. Initial reference measurements were conducted. Alternatively, tests were performed using Plessey Semiconductors capacitive sensors. Acceleration signals are gathered.
- 1 January 2013
- Published by Springer Nature
- p. 1-28
Impedance Detection
- Open Access
- 11 April 2012
- Published by IntechOpen
Aspects of Using Chirp Excitation for Estimation of Bioimpedance Spectrum
Aspects of Using Chirp Excitation for Estimation of Bioimpedance Spectrum | InTechOpen, Published on: 2012-04-11. Authors: Toivo Paavle, Mart Min and Toomas Parve
- 11 April 2012
- Published by IntechOpen
Open AccessAspects of Using Chirp Excitation for Estimation of Bioimpedance Spectrum
Aspects of Using Chirp Excitation for Estimation of Bioimpedance Spectrum | InTechOpen, Published on: 2012-04-11. Authors: Toivo Paavle, Mart Min and Toomas Parve
- 1 January 2008
- Published by Springer Nature in IFMBE Proceedings
- p. 425-428
Development of the Biomedical Electronics Course for e-Learning
- 1 January 2008
- Published by Springer Nature in IFMBE Proceedings
- p. 425-428
Development of the Biomedical Electronics Course for e-Learning
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 6308-6311
Intracardiac Electrical Bioimpedance as a Basis for Controlling of Pacing Rate Limits
Intracardiac impedance can provide real-time hemodynamic information to automatically control the lower and upper rate limits of a rate-adaptive pacemaker. It is necessary to overcome a number of technical challenges to accomplish this within the constraints of an implantable device
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 6308-6311
Intracardiac Electrical Bioimpedance as a Basis for Controlling of Pacing Rate Limits
Intracardiac impedance can provide real-time hemodynamic information to automatically control the lower and upper rate limits of a rate-adaptive pacemaker. It is necessary to overcome a number of technical challenges to accomplish this within the constraints of an implantable device
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 6308-6311
Intracardiac Electrical Bioimpedance as a Basis for Controlling of Pacing Rate Limits
Intracardiac impedance can provide real-time hemodynamic information to automatically control the lower and upper rate limits of a rate-adaptive pacemaker. It is necessary to overcome a number of technical challenges to accomplish this within the constraints of an implantable device
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 6308-6311
Intracardiac Electrical Bioimpedance as a Basis for Controlling of Pacing Rate Limits
Intracardiac impedance can provide real-time hemodynamic information to automatically control the lower and upper rate limits of a rate-adaptive pacemaker. It is necessary to overcome a number of technical challenges to accomplish this within the constraints of an implantable device