Mart Min
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mart Min has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Toomas Parve
11 shared publicationsPaul Annus
8 shared publicationsToivo Paavle
Dept. of Electronics, Tallinn University of Technology, 19086 Tallinn, Estonia
8 shared publicationsRaul Land
5 shared publications- Toomas Parve
Tallinn University of Technology
4 shared publications - Andres Kink
SmartImplant, Ltd. Tallinn 12618, Estonia. phone: +372 5063881; fax: +372 6202151
2 shared publications
Latest Publications
- 25 June 2021
- Published by Elsevier
Acknowledgments
- 1 January 2013
- Published by Springer Nature
- p. 1-28
Impedance Detection
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 12 (1094687X) , 134-137
Binary signals in impedance spectroscopy
Using of binary waveforms in the fast impedance spectroscopy of biological objects is discussed in the paper. There is shown that the energy of binary waveforms can be concentrated onto selected separate frequencies. We can optimize the binary excitation waveform depending on the shape of frequency response of the impedance under study to maximize the levels of signal components with certain selected frequencies. As a result, we are able to receive maximal amount of information about the properties and behavior of the impedance to be studied. We have designed and prototyped the impedance spectroscopy device operating in the frequency range from 100 mHz to 500 kHz to cover α- and β-regions of the bio-impedance spectrum of time-varying subjects as, for example, fast moving cells in micro-fluidic devices, beating heart and breathing lungs or the whole cardiovascular system.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 12 (1094687X) , 134-137
Binary signals in impedance spectroscopy
Using of binary waveforms in the fast impedance spectroscopy of biological objects is discussed in the paper. There is shown that the energy of binary waveforms can be concentrated onto selected separate frequencies. We can optimize the binary excitation waveform depending on the shape of frequency response of the impedance under study to maximize the levels of signal components with certain selected frequencies. As a result, we are able to receive maximal amount of information about the properties and behavior of the impedance to be studied. We have designed and prototyped the impedance spectroscopy device operating in the frequency range from 100 mHz to 500 kHz to cover α- and β-regions of the bio-impedance spectrum of time-varying subjects as, for example, fast moving cells in micro-fluidic devices, beating heart and breathing lungs or the whole cardiovascular system.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 398-402
Low-energy chirps for bioimpedance measurement
Using of Minimal Length Chirps (MLC) as excitation signals for the bioimpedance measurement is discussed in this paper. It is shown that reducing the length of chirps and thereby minimizing the required signal energy still allows for a fast and wideband estimation of the bioimpedance. This is very important in the field of implantable and wearable devices, where low power consumption is mandatory. In addition we present a practical signal generation solution based on digital low-cost components.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 398-402
Low-energy chirps for bioimpedance measurement
Using of Minimal Length Chirps (MLC) as excitation signals for the bioimpedance measurement is discussed in this paper. It is shown that reducing the length of chirps and thereby minimizing the required signal energy still allows for a fast and wideband estimation of the bioimpedance. This is very important in the field of implantable and wearable devices, where low power consumption is mandatory. In addition we present a practical signal generation solution based on digital low-cost components.
- 7 June 2011
- Published by IOP Publishing in Physiological Measurement
- Vol. 32 (7) , 945-958
Broadband spectroscopy of dynamic impedances with short chirp pulses
An impedance spectrum of dynamic systems is time dependent. Fast impedance changes take place, for example, in high throughput microfluidic devices and in operating cardiovascular systems. Measurements must be as short as possible to avoid significant impedance changes during the spectrum analysis, and as long as possible for enlarging the excitation energy and obtaining a better signal-to-noise ratio (SNR). The authors propose to use specific short chirp pulses for excitation. Thanks to the specific properties of the chirp function, it is possible to meet the needs for a spectrum bandwidth, measurement time and SNR so that the most accurate impedance spectrogram can be obtained. The chirp wave excitation can include thousands of cycles when the impedance changes slowly, but in the case of very high speed changes it can be shorter than a single cycle, preserving the same excitation bandwidth. For example, a 100 kHz bandwidth can be covered by the chirp pulse with durations from 10 µs to 1 s; only its excitation energy differs also 10(5) times. After discussing theoretical short chirp properties in detail, the authors show how to generate short chirps in the microsecond range with a bandwidth up to a few MHz by using digital synthesis architectures developed inside a low-cost standard field programmable gate array.
- 7 June 2011
- Published by IOP Publishing in Physiological Measurement
- Vol. 32 (7) , 945-958
Broadband spectroscopy of dynamic impedances with short chirp pulses
An impedance spectrum of dynamic systems is time dependent. Fast impedance changes take place, for example, in high throughput microfluidic devices and in operating cardiovascular systems. Measurements must be as short as possible to avoid significant impedance changes during the spectrum analysis, and as long as possible for enlarging the excitation energy and obtaining a better signal-to-noise ratio (SNR). The authors propose to use specific short chirp pulses for excitation. Thanks to the specific properties of the chirp function, it is possible to meet the needs for a spectrum bandwidth, measurement time and SNR so that the most accurate impedance spectrogram can be obtained. The chirp wave excitation can include thousands of cycles when the impedance changes slowly, but in the case of very high speed changes it can be shorter than a single cycle, preserving the same excitation bandwidth. For example, a 100 kHz bandwidth can be covered by the chirp pulse with durations from 10 µs to 1 s; only its excitation energy differs also 10(5) times. After discussing theoretical short chirp properties in detail, the authors show how to generate short chirps in the microsecond range with a bandwidth up to a few MHz by using digital synthesis architectures developed inside a low-cost standard field programmable gate array.
- 1 April 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 224
Broadband spectroscopy of a dynamic impedance
- 1 April 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 224
Broadband spectroscopy of a dynamic impedance
- 1 November 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
High speed data preprocessing for bioimpedance measurements: Architectural exploration
Measurement of electrical bioimpedance enables to characterize tissues and organs, to get diagnostic images, etc. In this paper, various architectural solutions of digital data preprocessing unit for multichannel bioimpedance analyzer are explored. Extensions for the existing prototype analyzer are discussed keeping in mind performance and cost requirements.
- 1 November 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
High speed data preprocessing for bioimpedance measurements: Architectural exploration
Measurement of electrical bioimpedance enables to characterize tissues and organs, to get diagnostic images, etc. In this paper, various architectural solutions of digital data preprocessing unit for multichannel bioimpedance analyzer are explored. Extensions for the existing prototype analyzer are discussed keeping in mind performance and cost requirements.
- 1 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 421-424
Wideband object identification with rectangular wave chirp excitation
Using of chirp-type excitations for the fast broadband measurement and estimation of the complex bioimpedance is discussed in this paper. The proposed method includes cross-correlation of the excitation (reference) and response signals with a subsequent Fourier analysis of the obtained correlation function. It is shown that the phase response can be especially convenient for estimating of the state of a biological object and for monitoring the processes taking place in it. The results of this study stand for elaborating the respective off-chip and on-chip measurement devices with rectangular wave chirp pulses as excitation.
- 1 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 421-424
Wideband object identification with rectangular wave chirp excitation
Using of chirp-type excitations for the fast broadband measurement and estimation of the complex bioimpedance is discussed in this paper. The proposed method includes cross-correlation of the excitation (reference) and response signals with a subsequent Fourier analysis of the obtained correlation function. It is shown that the phase response can be especially convenient for estimating of the state of a biological object and for monitoring the processes taking place in it. The results of this study stand for elaborating the respective off-chip and on-chip measurement devices with rectangular wave chirp pulses as excitation.