Jeffrey Coughenour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jeffrey Coughenour has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Stephen L. Barnes
University of Missouri
3 shared publications - Gary L. Lewis
University of Missouri Environmental Health and Safety
1 shared publication - Jacob A. Quick
Department of Surgery, Division of Acute Care Surgery, University of Missouri, 1 Hospital Drive, MC220, Columbia, MO 65212, USA
1 shared publication Stephen M. Welch
1 shared publication
Latest Publications
- 6 November 2018
- Vol. 115 (5) , 429-433
Initial Evaluation and Management of the Injured Patient.
This update is a conversation with our trauma medical director about the initial evaluation and management of the injured patient. After a brief historical perspective, we discuss the immediate treatment of life-threatening injuries at local hospitals within the context of definitive care at a level 1 trauma center. Our journey is colored by recent cases we have treated at our institution with the hope that we save more Missourian lives.
- 6 November 2018
- Vol. 115 (5) , 429-433
Initial Evaluation and Management of the Injured Patient.
This update is a conversation with our trauma medical director about the initial evaluation and management of the injured patient. After a brief historical perspective, we discuss the immediate treatment of life-threatening injuries at local hospitals within the context of definitive care at a level 1 trauma center. Our journey is colored by recent cases we have treated at our institution with the hope that we save more Missourian lives.
- 10 April 2018
- Published by Wiley
- p. 69-78
Airway and Perioperative Management
- 19 September 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 21 (1) , 11-15
Provider X-ray exposure in the trauma bay: results of a radiation field analysis
Radiation exposure during trauma care has increased in recent years. Radiation risk to providers during the care of injured patients is not well defined. We aimed to gather environmental exposure data from dosimeters placed at fixed points in the trauma bay to act as surrogates for personnel radiation exposure during trauma team activations. Forty-four (44) radiation dosimeters were placed throughout a single trauma bay in a university level 1 trauma center. We analyzed shallow (SDE) and deep dose equivalents (DDE) over 6 months. We measured distance from the radiation source for each dosimeter. Four controls were included. We recorded patient injury and X-ray data for each patient. During the study period, 417 patients were evaluated in the trauma bay under study. Mean ISS was 14.3 (range 0-75). A total of 2,107 plain X-rays were taken, with a mean of 5.1 X-rays per patient (range 0-32). Extremity films were most often performed, followed by chest and shoulder films. No measurable dose was identified with the dosimeter controls. The majority (27, 68 %) of dosimeters registered the lowest doses (<1 mSv DDE). Five dosimeters revealed doses between 1 and 2 mSv DDE. Four dosimeters registered over 2 mSv DDE, with a mean DDE of 3 mSv. Distances of less than 5 ft from the radiation source had the highest DDE dose. Maximum annual occupational DDE dose is conventionally 50 mSv. None of the dosimeters registered DDE doses over 4.31 mSv during the study period, supporting low radiation risk to providers in the trauma bay.
- 19 September 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 21 (1) , 11-15
Provider X-ray exposure in the trauma bay: results of a radiation field analysis
Radiation exposure during trauma care has increased in recent years. Radiation risk to providers during the care of injured patients is not well defined. We aimed to gather environmental exposure data from dosimeters placed at fixed points in the trauma bay to act as surrogates for personnel radiation exposure during trauma team activations. Forty-four (44) radiation dosimeters were placed throughout a single trauma bay in a university level 1 trauma center. We analyzed shallow (SDE) and deep dose equivalents (DDE) over 6 months. We measured distance from the radiation source for each dosimeter. Four controls were included. We recorded patient injury and X-ray data for each patient. During the study period, 417 patients were evaluated in the trauma bay under study. Mean ISS was 14.3 (range 0-75). A total of 2,107 plain X-rays were taken, with a mean of 5.1 X-rays per patient (range 0-32). Extremity films were most often performed, followed by chest and shoulder films. No measurable dose was identified with the dosimeter controls. The majority (27, 68 %) of dosimeters registered the lowest doses (<1 mSv DDE). Five dosimeters revealed doses between 1 and 2 mSv DDE. Four dosimeters registered over 2 mSv DDE, with a mean DDE of 3 mSv. Distances of less than 5 ft from the radiation source had the highest DDE dose. Maximum annual occupational DDE dose is conventionally 50 mSv. None of the dosimeters registered DDE doses over 4.31 mSv during the study period, supporting low radiation risk to providers in the trauma bay.
- 24 April 2012
- Published by Wiley
- p. 62-75
Airway Management, Anesthesia, and Perioperative Management