Jacquelyn C. Yanch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jacquelyn C. Yanch has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Bevin Engelward
Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts
1 shared publicationBevin P. Engelward
Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139; † Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139
1 shared publicationJohn H. McCall
1 shared publicationMatthew Davidson
Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139; † Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139
1 shared publicationMichael J. Hendricks
1 shared publicationRichard H. Behrman
1 shared publication
Latest Publications
- Open Access
- 1 October 2012
- Published by American Chemical Society (ACS) in Environmental Health Perspectives
- Vol. 120 (10) , a383-a384
DNA Damage after Continuous Irradiation: Yanch and Engelward Respond
- 1 October 2012
- Published by American Chemical Society (ACS) in Environmental Health Perspectives
- Vol. 120 (10) , a383-a384
Open AccessDNA Damage after Continuous Irradiation: Yanch and Engelward Respond
- 28 September 2012
- Published by Springer Nature
- p. 521-530
Boron Neutron Capture Synovectomy
- Open Access
- 1 May 2010
- Published by Wolters Kluwer Health in Health Physics
- Vol. 98 (5) , 727-734
DEVELOPMENT AND CHARACTERIZATION OF A NOVEL VARIABLE LOW DOSE-RATE IRRADIATOR FOR IN VIVO MOUSE STUDIES
Radiation exposure of humans generally results in low doses delivered at low dose rate. Our limited knowledge of the biological effects of low dose radiation is mainly based on data from the atomic bomb Life Span Study (LSS) cohort. However, the total doses and dose rates in the LSS cohort are still higher than most environmental and occupational exposures in humans. Importantly, the dose rate is a critical determinant of health risks stemming from radiation exposure. Understanding the shape of the dose-rate response curve for different biological outcomes is thus crucial for projecting the biological hazard from radiation in different environmental and man-made conditions. A significant barrier to performing low dose-rate studies is the difficulty in creating radiation source configurations compatible with long-term cellular or animal experiments. In this study the design and characterization of a large area, 125I-based irradiator is described. The irradiator allows continuous long-term exposure of mice at variable dose rates and can be sited in standard animal care facilities. The dose rate is determined by the level of 125I activity added to a large NaOH-filled rectangular phantom. The desired dose rate is maintained at essentially constant levels by weekly additions of 125I to compensate for decay. Dosimetry results for long-term animal irradiation at targeted dose rates of 0.00021 and 0.0021 cGy min−1 are presented.
- 1 May 2010
- Published by Wolters Kluwer Health in Health Physics
- Vol. 98 (5) , 727-734
Open AccessDEVELOPMENT AND CHARACTERIZATION OF A NOVEL VARIABLE LOW DOSE-RATE IRRADIATOR FOR IN VIVO MOUSE STUDIES
Radiation exposure of humans generally results in low doses delivered at low dose rate. Our limited knowledge of the biological effects of low dose radiation is mainly based on data from the atomic bomb Life Span Study (LSS) cohort. However, the total doses and dose rates in the LSS cohort are still higher than most environmental and occupational exposures in humans. Importantly, the dose rate is a critical determinant of health risks stemming from radiation exposure. Understanding the shape of the dose-rate response curve for different biological outcomes is thus crucial for projecting the biological hazard from radiation in different environmental and man-made conditions. A significant barrier to performing low dose-rate studies is the difficulty in creating radiation source configurations compatible with long-term cellular or animal experiments. In this study the design and characterization of a large area, 125I-based irradiator is described. The irradiator allows continuous long-term exposure of mice at variable dose rates and can be sited in standard animal care facilities. The dose rate is determined by the level of 125I activity added to a large NaOH-filled rectangular phantom. The desired dose rate is maintained at essentially constant levels by weekly additions of 125I to compensate for decay. Dosimetry results for long-term animal irradiation at targeted dose rates of 0.00021 and 0.0021 cGy min−1 are presented.
- Open Access
- 1 July 2009
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 252 (1) , 128-139
Increased Radiation Dose to Overweight and Obese Patients from Radiographic Examinations
To estimate the increase in effective radiation dose from diagnostic x-rays for overweight and obese adult patients, as compared with the effective dose for lean reference phantoms. Relative effective radiation doses (E/E(0)) for the acquisition of chest and abdominal radiographs were calculated by using Monte Carlo computer simulations of effective doses delivered to adult phantoms with (E) and without (E(0)) subcutaneous adipose tissue added to the torso for five fat distributions. Total (anterior plus posterior) fat thicknesses ranged from 0 to 38 cm. For 30 cm of additional fat, E/E(0) values for 120-kVp chest and 80-kVp abdomen radiographs ranged from approximately 2 to 31 and 2 to 83 for male patients, respectively, and from 2 to 45 and 2 to 76 for female patients, respectively, depending on the type of fat distribution and patient orientation in the x-ray beam (anteroposterior or posteroanterior). Orienting the patient such that the thinnest fat layer was facing away from the x-ray tube minimized E/E(0), which was well approximated by using the formula E/E(0) = [B(t)/B(0)] x exp(kt(DF)), where B(t) and B(0) are the antiscatter grid Bucky factors for patient thicknesses of t and t = 20 cm, respectively; k, a constant; and t(DF), the distal (beam exit) fat layer thickness. Reductions in E/E(0) reached 14% and 20% for the thickest phantoms when x-ray tube voltages were increased by 10 and 20 kVp, respectively, for abdominal radiography in the male phantom. Effective doses from radiographic examinations in the extremely obese can exceed 100 mSv from only a small number of abdominal examinations and should be minimized to the extent possible and monitored. Exponential dose increases for increased subcutaneous fat thicknesses can be reduced substantially by positioning the patient so that the thinnest fat layer (anterior or posterior) is closest to the image receptor. Increasing the tube voltage also reduces the dose-but to a much smaller extent.
- 1 July 2009
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 252 (1) , 128-139
Open AccessIncreased Radiation Dose to Overweight and Obese Patients from Radiographic Examinations
To estimate the increase in effective radiation dose from diagnostic x-rays for overweight and obese adult patients, as compared with the effective dose for lean reference phantoms. Relative effective radiation doses (E/E(0)) for the acquisition of chest and abdominal radiographs were calculated by using Monte Carlo computer simulations of effective doses delivered to adult phantoms with (E) and without (E(0)) subcutaneous adipose tissue added to the torso for five fat distributions. Total (anterior plus posterior) fat thicknesses ranged from 0 to 38 cm. For 30 cm of additional fat, E/E(0) values for 120-kVp chest and 80-kVp abdomen radiographs ranged from approximately 2 to 31 and 2 to 83 for male patients, respectively, and from 2 to 45 and 2 to 76 for female patients, respectively, depending on the type of fat distribution and patient orientation in the x-ray beam (anteroposterior or posteroanterior). Orienting the patient such that the thinnest fat layer was facing away from the x-ray tube minimized E/E(0), which was well approximated by using the formula E/E(0) = [B(t)/B(0)] x exp(kt(DF)), where B(t) and B(0) are the antiscatter grid Bucky factors for patient thicknesses of t and t = 20 cm, respectively; k, a constant; and t(DF), the distal (beam exit) fat layer thickness. Reductions in E/E(0) reached 14% and 20% for the thickest phantoms when x-ray tube voltages were increased by 10 and 20 kVp, respectively, for abdominal radiography in the male phantom. Effective doses from radiographic examinations in the extremely obese can exceed 100 mSv from only a small number of abdominal examinations and should be minimized to the extent possible and monitored. Exponential dose increases for increased subcutaneous fat thicknesses can be reduced substantially by positioning the patient so that the thinnest fat layer (anterior or posterior) is closest to the image receptor. Increasing the tube voltage also reduces the dose-but to a much smaller extent.