JYJacquelyn C. Yanch

Jacquelyn C. Yanch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jacquelyn C. Yanch has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Bevin Engelward

    Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts

    1 shared publication
  • Bevin P. Engelward

    Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139; † Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139

    1 shared publication
  • John H. McCall

    1 shared publication
  • Matthew Davidson

    Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139; † Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139

    1 shared publication
  • Michael J. Hendricks

    1 shared publication
  • Richard H. Behrman

    1 shared publication

Latest Publications

  • Boron Neutron Capture Synovectomy

    by Jacquelyn C. Yanch

  • Open Access

    DEVELOPMENT AND CHARACTERIZATION OF A NOVEL VARIABLE LOW DOSE-RATE IRRADIATOR FOR IN VIVO MOUSE STUDIES

    by Werner Olipitz, Sheena Hembrador, Matthew Davidson, Jacquelyn C. Yanch, Bevin P. Engelward

    Radiation exposure of humans generally results in low doses delivered at low dose rate. Our limited knowledge of the biological effects of low dose radiation is mainly based on data from the atomic bomb Life Span Study (LSS) cohort. However, the total doses and dose rates in the LSS cohort are still higher than most environmental and occupational exposures in humans. Importantly, the dose rate is a critical determinant of health risks stemming from radiation exposure. Understanding the shape of the dose-rate response curve for different biological outcomes is thus crucial for projecting the biological hazard from radiation in different environmental and man-made conditions. A significant barrier to performing low dose-rate studies is the difficulty in creating radiation source configurations compatible with long-term cellular or animal experiments. In this study the design and characterization of a large area, 125I-based irradiator is described. The irradiator allows continuous long-term exposure of mice at variable dose rates and can be sited in standard animal care facilities. The dose rate is determined by the level of 125I activity added to a large NaOH-filled rectangular phantom. The desired dose rate is maintained at essentially constant levels by weekly additions of 125I to compensate for decay. Dosimetry results for long-term animal irradiation at targeted dose rates of 0.00021 and 0.0021 cGy min−1 are presented.


  • Open Access

    Increased Radiation Dose to Overweight and Obese Patients from Radiographic Examinations

    by Jacquelyn C. Yanch, Richard H. Behrman, Michael J. Hendricks, John H. McCall

    To estimate the increase in effective radiation dose from diagnostic x-rays for overweight and obese adult patients, as compared with the effective dose for lean reference phantoms. Relative effective radiation doses (E/E(0)) for the acquisition of chest and abdominal radiographs were calculated by using Monte Carlo computer simulations of effective doses delivered to adult phantoms with (E) and without (E(0)) subcutaneous adipose tissue added to the torso for five fat distributions. Total (anterior plus posterior) fat thicknesses ranged from 0 to 38 cm. For 30 cm of additional fat, E/E(0) values for 120-kVp chest and 80-kVp abdomen radiographs ranged from approximately 2 to 31 and 2 to 83 for male patients, respectively, and from 2 to 45 and 2 to 76 for female patients, respectively, depending on the type of fat distribution and patient orientation in the x-ray beam (anteroposterior or posteroanterior). Orienting the patient such that the thinnest fat layer was facing away from the x-ray tube minimized E/E(0), which was well approximated by using the formula E/E(0) = [B(t)/B(0)] x exp(kt(DF)), where B(t) and B(0) are the antiscatter grid Bucky factors for patient thicknesses of t and t = 20 cm, respectively; k, a constant; and t(DF), the distal (beam exit) fat layer thickness. Reductions in E/E(0) reached 14% and 20% for the thickest phantoms when x-ray tube voltages were increased by 10 and 20 kVp, respectively, for abdominal radiography in the male phantom. Effective doses from radiographic examinations in the extremely obese can exceed 100 mSv from only a small number of abdominal examinations and should be minimized to the extent possible and monitored. Exponential dose increases for increased subcutaneous fat thicknesses can be reduced substantially by positioning the patient so that the thinnest fat layer (anterior or posterior) is closest to the image receptor. Increasing the tube voltage also reduces the dose-but to a much smaller extent.