Amin Yazdanpanah Goharrizi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amin Yazdanpanah Goharrizi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Rajiv Chopra
Department of Radiology, UT Southwestern Medical Center
2 shared publications Raymond Kwong
Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada
2 shared publications- Nariman Sepehri
Department of Mechanical Engineering, University of Manitoba, Winnipeg, Manitoba R3T 5V6, Canada
1 shared publication - William Apoutou N'DJin
LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France
1 shared publication - Yan Wu
Georgia Southern University
1 shared publication
Latest Publications
- 14 October 2014
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 30 (7) , 438-446
Development of robust/predictive control strategies for image-guided ablative treatments using a minimally invasive ultrasound applicator
Purpose: One important challenge in image-guided ablative therapies is the effect of heat diffusion which can cause damage to surrounding organs and limit the ability to achieve a conformal pattern of thermal damage. Furthermore, tissue properties such as perfusion and energy absorption can be dynamic and difficult to measure. This paper attempts to address these problems by proposing new control methods. Materials and methods: A novel predictive approach was developed to compensate for the effect of heat diffusion using a minimally invasive rotating ultrasound heating applicator for ablative therapy. This method can be merged into any closed-loop control strategy. A binary controller, a previously developed adaptive proportional-integral controller, and a model reference adaptive controller were employed and compared, all with the predictive element incorporated. The reason for choosing these controllers was that none of them needed a model of the tissue or exact values of their parameters. Results: The effectiveness of these controllers was demonstrated through both simulation and experimental studies. The results were consistent and demonstrated equivalent performance between controllers. Conclusions: The dominant influence on radial targeting accuracy was the prediction element described in this paper. A binary controller with a predictive element may provide the best balance of performance and simplicity for this application.
- 14 October 2014
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 30 (7) , 438-446
Development of robust/predictive control strategies for image-guided ablative treatments using a minimally invasive ultrasound applicator
Purpose: One important challenge in image-guided ablative therapies is the effect of heat diffusion which can cause damage to surrounding organs and limit the ability to achieve a conformal pattern of thermal damage. Furthermore, tissue properties such as perfusion and energy absorption can be dynamic and difficult to measure. This paper attempts to address these problems by proposing new control methods. Materials and methods: A novel predictive approach was developed to compensate for the effect of heat diffusion using a minimally invasive rotating ultrasound heating applicator for ablative therapy. This method can be merged into any closed-loop control strategy. A binary controller, a previously developed adaptive proportional-integral controller, and a model reference adaptive controller were employed and compared, all with the predictive element incorporated. The reason for choosing these controllers was that none of them needed a model of the tissue or exact values of their parameters. Results: The effectiveness of these controllers was demonstrated through both simulation and experimental studies. The results were consistent and demonstrated equivalent performance between controllers. Conclusions: The dominant influence on radial targeting accuracy was the prediction element described in this paper. A binary controller with a predictive element may provide the best balance of performance and simplicity for this application.
- 26 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 033301
Development of a new control strategy for 3D MRI‐controlled interstitial ultrasound cancer therapy
Purpose:: MRI‐controlled interstitial ultrasound therapy is being developed as a minimally invasive, image‐guided treatment for localized cancers. The method uses an interstitial multielement ultrasound applicator to deliver high‐intensity ultrasound energy to tissue in order to achieve thermal coagulation in a target volume.Methods:: A new temperature feedback control algorithm incorporating a proportional‐integral controller is introduced to tackle a multiple‐input single‐output control problem arising in MRI‐controlled interstitial ultrasound cancer therapy. The inputs to the controller block are the frequency, rotation rate, and applied power of an interstitial applicator and the output is the boundary temperature during treatment. Multiplanar magnetic resonance (MR) thermometry is acquired continuously during heating and used in the feedback control algorithm to achieve spatial control over treatment.Results:: The method has been evaluated for prostate cancer treatment as an initial clinical application. Spatial treatment accuracy of a few millimeters is demonstrated in both simulations and experiments with the new controller. The spatial treatment accuracy of the new algorithm is shown to be equivalent or slightly improved over the existing approach implemented for this technology; however, the implementation of the new algorithm is much simpler, and does not involve time‐intensive tuning of gain constants.Conclusions:: The study demonstrates the potential advantages of a new automatic temperature control system adapted to image guided interstitial ultrasound therapy.
- 26 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 033301
Development of a new control strategy for 3D MRI‐controlled interstitial ultrasound cancer therapy
Purpose:: MRI‐controlled interstitial ultrasound therapy is being developed as a minimally invasive, image‐guided treatment for localized cancers. The method uses an interstitial multielement ultrasound applicator to deliver high‐intensity ultrasound energy to tissue in order to achieve thermal coagulation in a target volume.Methods:: A new temperature feedback control algorithm incorporating a proportional‐integral controller is introduced to tackle a multiple‐input single‐output control problem arising in MRI‐controlled interstitial ultrasound cancer therapy. The inputs to the controller block are the frequency, rotation rate, and applied power of an interstitial applicator and the output is the boundary temperature during treatment. Multiplanar magnetic resonance (MR) thermometry is acquired continuously during heating and used in the feedback control algorithm to achieve spatial control over treatment.Results:: The method has been evaluated for prostate cancer treatment as an initial clinical application. Spatial treatment accuracy of a few millimeters is demonstrated in both simulations and experiments with the new controller. The spatial treatment accuracy of the new algorithm is shown to be equivalent or slightly improved over the existing approach implemented for this technology; however, the implementation of the new algorithm is much simpler, and does not involve time‐intensive tuning of gain constants.Conclusions:: The study demonstrates the potential advantages of a new automatic temperature control system adapted to image guided interstitial ultrasound therapy.
- 1 January 2011
- Published by River Publishers in International Journal of Fluid Power
- Vol. 12 (2) , 37-47
A Wavelet-Based Approach for Online External Leakage Diagnosis and Isolation from Internal Leakage in Hydraulic Actuators
This paper presents experimental evaluation of applying wavelet transform for on-line external leakage fault detection and isolation from internal leakage in hydraulic actuators. In this work, the more realistic case of an actuator that is driven to track pseudorandom position reference inputs against a load is considered. The wavelet-based method developed in this paper, decomposes a limited-duration pressure signal at either chamber of a hydraulic actuator into effective approximate and detail wavelet coefficients. The limited-duration pressure signal is collected using a sliding window technique. It is shown that the root mean square (RMS) value of the level four approximate wavelet coefficient collectively establishes a feature index that can effectively be used for on-line detection of external leakage. Once the external leakage occurs, this index value decreases proportionally. Therefore, one can report the faulty operating condition by monitoring this index. Additionally, built upon the previous work in which the level two detail coefficient was found to be sensitive to internal leakage fault, we further investigate the isolation of external leakage from internal leakage in an actuator. Extensive validation tests demonstrate the effectiveness of the proposed technique, given any position reference input, loading condition, and controller type or effectiveness. Experimental tests show promising results for detecting external leakage as low as 0.3 L/min and isolating it from internal leakage as low as 0.48 L/min, during an on-line testing procedure.
- 1 January 2011
- Published by River Publishers in International Journal of Fluid Power
- Vol. 12 (2) , 37-47
A Wavelet-Based Approach for Online External Leakage Diagnosis and Isolation from Internal Leakage in Hydraulic Actuators
This paper presents experimental evaluation of applying wavelet transform for on-line external leakage fault detection and isolation from internal leakage in hydraulic actuators. In this work, the more realistic case of an actuator that is driven to track pseudorandom position reference inputs against a load is considered. The wavelet-based method developed in this paper, decomposes a limited-duration pressure signal at either chamber of a hydraulic actuator into effective approximate and detail wavelet coefficients. The limited-duration pressure signal is collected using a sliding window technique. It is shown that the root mean square (RMS) value of the level four approximate wavelet coefficient collectively establishes a feature index that can effectively be used for on-line detection of external leakage. Once the external leakage occurs, this index value decreases proportionally. Therefore, one can report the faulty operating condition by monitoring this index. Additionally, built upon the previous work in which the level two detail coefficient was found to be sensitive to internal leakage fault, we further investigate the isolation of external leakage from internal leakage in an actuator. Extensive validation tests demonstrate the effectiveness of the proposed technique, given any position reference input, loading condition, and controller type or effectiveness. Experimental tests show promising results for detecting external leakage as low as 0.3 L/min and isolating it from internal leakage as low as 0.48 L/min, during an on-line testing procedure.