Development of robust/predictive control strategies for image-guided ablative treatments using a minimally invasive ultrasound applicator
- 14 October 2014
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 30 (7) , 438-446
Abstract
Purpose: One important challenge in image-guided ablative therapies is the effect of heat diffusion which can cause damage to surrounding organs and limit the ability to achieve a conformal pattern of thermal damage. Furthermore, tissue properties such as perfusion and energy absorption can be dynamic and difficult to measure. This paper attempts to address these problems by proposing new control methods. Materials and methods: A novel predictive approach was developed to compensate for the effect of heat diffusion using a minimally invasive rotating ultrasound heating applicator for ablative therapy. This method can be merged into any closed-loop control strategy. A binary controller, a previously developed adaptive proportional-integral controller, and a model reference adaptive controller were employed and compared, all with the predictive element incorporated. The reason for choosing these controllers was that none of them needed a model of the tissue or exact values of their parameters. Results: The effectiveness of these controllers was demonstrated through both simulation and experimental studies. The results were consistent and demonstrated equivalent performance between controllers. Conclusions: The dominant influence on radial targeting accuracy was the prediction element described in this paper. A binary controller with a predictive element may provide the best balance of performance and simplicity for this application.Keywords
This publication has 17 references indexed in Scilit:
- A review of numerical and experimental compensation techniques for skull-induced phase aberrations in transcranial focused ultrasoundInternational Journal of Hyperthermia, 2013
- MR thermometry in the human prostate gland at 3.0T for transurethral ultrasound therapyJournal of Magnetic Resonance Imaging, 2013
- Endocavitary thermal therapy by MRI‐guided phased‐array contact ultrasound: Experimental and numerical studies on the multi‐input single‐output PID temperature controller's convergence and stabilityMedical Physics, 2009
- Quantitative analysis of 3-D conformal MRI-guided transurethral ultrasound therapy of the prostate: Theoretical simulationsInternational Journal of Hyperthermia, 2009
- Transurethral ultrasound applicators with dynamic multi‐sector control for prostate thermal therapy: In vivo evaluation under MR guidanceMedical Physics, 2008
- Adaptive real-time closed-loop temperature control for ultrasound hyperthermia using magnetic resonance thermometryConcepts in Magnetic Resonance Part B, 2005
- Highly directional transurethral ultrasound applicators with rotational control for MRI-guided prostatic thermal therapyPhysics in Medicine & Biology, 2004
- Model-predictive control of hyperthermia treatmentsIEEE Transactions on Biomedical Engineering, 2002
- Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human MuscleMagnetic Resonance in Medicine, 1995
- Sound field calculation for rectangular sourcesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1989