Nigel Howarth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nigel Howarth has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Denis Tack
Radiology Department, Hopital Epicura, 7800 Ath, Belgium
5 shared publications - Hanna Salame
EpiCura Hospital
2 shared publications Alain van Muylem
1 shared publication- Amanda Marlène Missi
Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
1 shared publication Arnaud Cornil
1 shared publication- Blandine Defrenne
Université Libre de Bruxelles, Faculté de Médecine, Route de Lennik 808, B-1070 Bruxelles
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 63
Unusual Air Crescents on Chest Radiographs
The air crescent (AC) is a common radiological sign. Even if its commonest aetiology remains pulmonary aspergillosis, various other causes have been described. In this study, we report four rare causes of ACs seen on chest radiographs that haven’t been described in the literature. Teaching point: The differential diagnosis of an air crescent sign on chest radiographs includes oesophageal bezoar, interstitial lung emphysema, central bronchial stenosis and perforated emphysematous cholecystitis.
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 63
Open AccessUnusual Air Crescents on Chest Radiographs
The air crescent (AC) is a common radiological sign. Even if its commonest aetiology remains pulmonary aspergillosis, various other causes have been described. In this study, we report four rare causes of ACs seen on chest radiographs that haven’t been described in the literature. Teaching point: The differential diagnosis of an air crescent sign on chest radiographs includes oesophageal bezoar, interstitial lung emphysema, central bronchial stenosis and perforated emphysematous cholecystitis.
- Open Access
- 12 May 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 100
Reject Analysis in Digital Radiography and Computed Tomography: A Belgian Imaging Department Case Study
Objective: Reject analysis is usually performed in digital radiography (DR) for quality assurance. Data for computed tomography (CT) rejects remains sparse. The aim of this study is to help provide a straightforward benchmark for reject analysis of both DR and CT. Materials and methods: This retrospective observational study included 107,277 DR and 20,659 CT during 18 months in a tertiary care center. Rejected acquisitions were retrieved by Dose Archiving and Communication System (DACS). The DR and CT reject analysis included reject rates, reasons for rejection and supplementary radiation dose associated with these rejects. Results: 8,904 rejected DR and 514 rejected CT were retrieved. The DR reject rate was 8.3% whereas the CT reject rate was 2.5%. The cumulative effective dose (ED) of DR rejects was 377.3 mSv while the cumulative ED of CT rejects was 1267.4 mSv. The major reason for rejects was positioning for both DR (61%) and CT (44%). Conclusion: This study helps constitute a simple reproducible method to analyze both DR and CT rejects simultaneously. Although CT rejects are less often monitored than DR rejects, the radiation dose associated with CT rejects is much higher, which emphasizes the need to systematically monitor both DR and CT rejects. Investigating the reasons and the most frequently rejected examinations gives an opportunity for improvement of imaging techniques in cooperation with technologists.
- 12 May 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 100
Open AccessReject Analysis in Digital Radiography and Computed Tomography: A Belgian Imaging Department Case Study
Objective: Reject analysis is usually performed in digital radiography (DR) for quality assurance. Data for computed tomography (CT) rejects remains sparse. The aim of this study is to help provide a straightforward benchmark for reject analysis of both DR and CT. Materials and methods: This retrospective observational study included 107,277 DR and 20,659 CT during 18 months in a tertiary care center. Rejected acquisitions were retrieved by Dose Archiving and Communication System (DACS). The DR and CT reject analysis included reject rates, reasons for rejection and supplementary radiation dose associated with these rejects. Results: 8,904 rejected DR and 514 rejected CT were retrieved. The DR reject rate was 8.3% whereas the CT reject rate was 2.5%. The cumulative effective dose (ED) of DR rejects was 377.3 mSv while the cumulative ED of CT rejects was 1267.4 mSv. The major reason for rejects was positioning for both DR (61%) and CT (44%). Conclusion: This study helps constitute a simple reproducible method to analyze both DR and CT rejects simultaneously. Although CT rejects are less often monitored than DR rejects, the radiation dose associated with CT rejects is much higher, which emphasizes the need to systematically monitor both DR and CT rejects. Investigating the reasons and the most frequently rejected examinations gives an opportunity for improvement of imaging techniques in cooperation with technologists.
- Open Access
- 9 December 2022
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 106 (1) , 127
Audit on Compliance to Guidelines in CT Scanning for Urolithiasis
According to the ALARA principle, CT-imaging procedures should be implemented to optimize radiation doses. The purpose of this study is to determine whether a quality control process has an impact on compliance with procedures. This retrospective study was conducted in three hospitals, focusing on the selection of the appropriate acquisition protocol and the reduction of acquisition height in abdominal computed tomography (CT) examinations performed to diagnose or rule out urolithiasis. A first audit was conducted to measure the compliance with the procedure. Next, a reminder of the CT-urolithiasis procedure was given to stakeholders. Three months later, a second audit was conducted to measure the impact of the repeat recall information on compliance, and to compare the outcome with an earlier audit conducted five years earlier. We included 517 ‘urolithiasis CT examinations’. The compliance ranged from 41.67% to 64.8% for the first audit. After the reminder of the urolithiasis procedure, compliance ranged from 50% to 76.10%. This improvement was statistically significant for hospital A and B (p < 0.001 for hospital A, p = 0.013 for hospital B) but not for hospital C (p = 0.405). Despite prior demonstration that improved compliance persisted at one year from an initial audit, our actual data show that this compliance had decreased at year five, confirming the need to repeat compliance audits more frequently, or to monitor it continuously. Surveying compliance to procedures can improve compliance but only for a limited duration. Monitoring compliance more frequently or even continuously is recommended.
- 9 December 2022
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 106 (1) , 127
Open AccessAudit on Compliance to Guidelines in CT Scanning for Urolithiasis
According to the ALARA principle, CT-imaging procedures should be implemented to optimize radiation doses. The purpose of this study is to determine whether a quality control process has an impact on compliance with procedures. This retrospective study was conducted in three hospitals, focusing on the selection of the appropriate acquisition protocol and the reduction of acquisition height in abdominal computed tomography (CT) examinations performed to diagnose or rule out urolithiasis. A first audit was conducted to measure the compliance with the procedure. Next, a reminder of the CT-urolithiasis procedure was given to stakeholders. Three months later, a second audit was conducted to measure the impact of the repeat recall information on compliance, and to compare the outcome with an earlier audit conducted five years earlier. We included 517 ‘urolithiasis CT examinations’. The compliance ranged from 41.67% to 64.8% for the first audit. After the reminder of the urolithiasis procedure, compliance ranged from 50% to 76.10%. This improvement was statistically significant for hospital A and B (p < 0.001 for hospital A, p = 0.013 for hospital B) but not for hospital C (p = 0.405). Despite prior demonstration that improved compliance persisted at one year from an initial audit, our actual data show that this compliance had decreased at year five, confirming the need to repeat compliance audits more frequently, or to monitor it continuously. Surveying compliance to procedures can improve compliance but only for a limited duration. Monitoring compliance more frequently or even continuously is recommended.
- Open Access
- 4 January 2021
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 105 (1)
Kommerell Aneurysm
Teaching Point: Kommerell aneurysm is a rare differential diagnosis of mediastinal enlargement on a chest radiograph that requires CT for accurate diagnosis.
- 4 January 2021
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 105 (1)
Open AccessKommerell Aneurysm
Teaching Point: Kommerell aneurysm is a rare differential diagnosis of mediastinal enlargement on a chest radiograph that requires CT for accurate diagnosis.
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 31 (1) , 23-28
Chest Computed Tomography Radiation Dose Optimization
Purpose: The aim of the study was to compare radiation dose and image quality between the "average" and the "very strong" automatic exposure control (AEC) strength curves. Materials and Methods: Images reconstructed with filtered backprojection techniques and radiation dose data of unenhanced helical chest computed tomography (CT) examinations obtained at 2 hospitals (hospital A, hospital B) using the same scanner devices and acquisition protocols but different AEC strength curves were evaluated over a 3-month period. The selected AEC strength curve applied to "slim" patients (diameter <32cm estimated from the attenuation automatically measured on the topogram) was "average" and "very strong" in hospital A and hospital B, respectively. Two radiologists with 13 and 24 years of experience scored the image quality of the lung parenchyma and the mediastinum on a 5-point scale. The patients' effective diameter, the delivered CT dose index volume, and dose-length products were recorded. Results: A total of 410 patients were included. The average body mass index was 24.0 kg/m2 in hospital A and 24.8 kg/m2 in hospital B. There was no significant difference between hospitals with respect to age, sex ratio, weight, height, body mass index, effective diameters, and image quality scores for each radiologist (P ranging from 0.050 to 1.000). The mean CT dose index volume for the entire population was 2.0mGy and was significantly lower in hospital B with the "very strong" AEC curve as compared with hospital A (-11%, P=0.001). The mean dose-length product delivered in this 70 kg-weight population was 68mGycm, corresponding to an effective dose of 0.95 mSv. Conclusion: Changing the AEC strength curve from "average" to "very strong" for slim patients maintains image quality and reduces the radiation dose to <1mSv in routine chest CT examinations reconstructed with filtered back-projection techniques.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 31 (1) , 23-28
Chest Computed Tomography Radiation Dose Optimization
Purpose: The aim of the study was to compare radiation dose and image quality between the "average" and the "very strong" automatic exposure control (AEC) strength curves. Materials and Methods: Images reconstructed with filtered backprojection techniques and radiation dose data of unenhanced helical chest computed tomography (CT) examinations obtained at 2 hospitals (hospital A, hospital B) using the same scanner devices and acquisition protocols but different AEC strength curves were evaluated over a 3-month period. The selected AEC strength curve applied to "slim" patients (diameter <32cm estimated from the attenuation automatically measured on the topogram) was "average" and "very strong" in hospital A and hospital B, respectively. Two radiologists with 13 and 24 years of experience scored the image quality of the lung parenchyma and the mediastinum on a 5-point scale. The patients' effective diameter, the delivered CT dose index volume, and dose-length products were recorded. Results: A total of 410 patients were included. The average body mass index was 24.0 kg/m2 in hospital A and 24.8 kg/m2 in hospital B. There was no significant difference between hospitals with respect to age, sex ratio, weight, height, body mass index, effective diameters, and image quality scores for each radiologist (P ranging from 0.050 to 1.000). The mean CT dose index volume for the entire population was 2.0mGy and was significantly lower in hospital B with the "very strong" AEC curve as compared with hospital A (-11%, P=0.001). The mean dose-length product delivered in this 70 kg-weight population was 68mGycm, corresponding to an effective dose of 0.95 mSv. Conclusion: Changing the AEC strength curve from "average" to "very strong" for slim patients maintains image quality and reduces the radiation dose to <1mSv in routine chest CT examinations reconstructed with filtered back-projection techniques.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
- 27 July 2007
- Published by Springer Nature
- p. 69-73
Imaging of Pulmonary Infections
- 1 September 1998
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 45 (1) , 67-69
Case of successful percutaneous stenting of an in situ gastroepiploic-coronary bypass graft
The in situ or free gastroepiploic artery (GEA) is being used as an arterial conduit for coronary artery bypass surgery (CABG). The recent rapid improvements in stent manufacture, particularly their profile and flexibility, and related equipment, have helped reduce complications of coronary angioplasty. We describe one case of successful stenting of an in situ GEA‐posterior descending artery graft. Stenting of an in situ GEA graft may avoid an incomplete result of angioplasty with possible restenosis or the need for multiple surgical revascularization. The use of stents in GEA grafts with 6 Fr soft guiding catheters can be encouraged. Cathet. Cardiovasc. Diagn. 45:67–69, 1998.
- 1 September 1998
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 45 (1) , 67-69
Case of successful percutaneous stenting of an in situ gastroepiploic-coronary bypass graft
The in situ or free gastroepiploic artery (GEA) is being used as an arterial conduit for coronary artery bypass surgery (CABG). The recent rapid improvements in stent manufacture, particularly their profile and flexibility, and related equipment, have helped reduce complications of coronary angioplasty. We describe one case of successful stenting of an in situ GEA‐posterior descending artery graft. Stenting of an in situ GEA graft may avoid an incomplete result of angioplasty with possible restenosis or the need for multiple surgical revascularization. The use of stents in GEA grafts with 6 Fr soft guiding catheters can be encouraged. Cathet. Cardiovasc. Diagn. 45:67–69, 1998.