Denis Tack
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Denis Tack has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Pierre Alain Gevenois
Department of Radiology, Hôpital Erasme, Université libre de Bruxelles (ULB), Brussels, Belgium
10 shared publicationsNigel Howarth
Department of Radiology, Clinique des Grangettes, Chêne-Bougeries, Switzerland
9 shared publications- Hanna Salame
EpiCura Hospital
8 shared publications - Thomas Saliba
Radiology Department, Erasme Hospital, Brussels, Belgium
7 shared publications Alain Van Muylem
Department of Chest Medicine, Hôpital Erasme, Route de Lennik 808, 1070, Brussels, Belgium
5 shared publications- Nigel Howarth
Hirslanden-Clinique des Grangettes, Genève
5 shared publications
Latest Publications
- Open Access
- 24 April 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (5) , 176
Can an Unenhanced Reduced-Dose ECG-Gated CT of the Aorta Replace an ECG-Gated CT-Angiography for Diameter Follow-Up of the Ascending Aorta?
Electrocardiogram (ECG)-gated contrast-enhanced computed tomography angiography (CTA) is the reference method for follow-up of ascending aortic aneurysms but delivers substantially higher radiation doses than ECG-gated non-contrast CT (NCCT). NCCT can be acquired at a lower dose while enabling measurements of the aortic outer diameter. This study aimed to quantify the radiation dose of both techniques and determine whether a significant difference exists in ascending thoracic aorta diameter measurements between NCCT and CTA. Eighty patients who underwent ECG-gated cardiac CT for suspected coronary artery disease were retrospectively analyzed. Three observers measured the ascending aortic diameter at the level of the pulmonary artery in a plane perpendicular to the aorta on both NCCT and CTA images. Inter-rater reliability was assessed using intraclass correlation coefficients, and paired samples t-tests were used to evaluate measurement differences. Dose-length products (DLP) were collected. Median DLP values were 16.1 mGy·cm (interquartile range 11.8–25.1) for NCCT and 190.3 mGy·cm (interquartile range 120.5–298.9) for CTA. NCCT measurements were consistently larger than CTA measurements, with mean differences of 2.1 ± 0.8 mm, 2.6 ± 0.96 mm, and 2.9 ± 1.09 mm for the senior radiologist, junior radiologist, and resident, respectively (all p < 0.001). Inter-observer agreement was excellent (ICC = 0.99, p < 0.001). NCCT delivered an 11.8-fold lower radiation dose than CTA. NCCT may replace CTA for ascending aortic diameter follow-up if measurements are adjusted by approximately 2–3 mm relative to CTA-derived inner-diameter thresholds.
- 24 April 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (5) , 176
Open AccessCan an Unenhanced Reduced-Dose ECG-Gated CT of the Aorta Replace an ECG-Gated CT-Angiography for Diameter Follow-Up of the Ascending Aorta?
Electrocardiogram (ECG)-gated contrast-enhanced computed tomography angiography (CTA) is the reference method for follow-up of ascending aortic aneurysms but delivers substantially higher radiation doses than ECG-gated non-contrast CT (NCCT). NCCT can be acquired at a lower dose while enabling measurements of the aortic outer diameter. This study aimed to quantify the radiation dose of both techniques and determine whether a significant difference exists in ascending thoracic aorta diameter measurements between NCCT and CTA. Eighty patients who underwent ECG-gated cardiac CT for suspected coronary artery disease were retrospectively analyzed. Three observers measured the ascending aortic diameter at the level of the pulmonary artery in a plane perpendicular to the aorta on both NCCT and CTA images. Inter-rater reliability was assessed using intraclass correlation coefficients, and paired samples t-tests were used to evaluate measurement differences. Dose-length products (DLP) were collected. Median DLP values were 16.1 mGy·cm (interquartile range 11.8–25.1) for NCCT and 190.3 mGy·cm (interquartile range 120.5–298.9) for CTA. NCCT measurements were consistently larger than CTA measurements, with mean differences of 2.1 ± 0.8 mm, 2.6 ± 0.96 mm, and 2.9 ± 1.09 mm for the senior radiologist, junior radiologist, and resident, respectively (all p < 0.001). Inter-observer agreement was excellent (ICC = 0.99, p < 0.001). NCCT delivered an 11.8-fold lower radiation dose than CTA. NCCT may replace CTA for ascending aortic diameter follow-up if measurements are adjusted by approximately 2–3 mm relative to CTA-derived inner-diameter thresholds.
- Open Access
- 1 January 2025
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 109 (1) , 61
Radiation Dose Alert: CT Overexposure As a Result of Patient Off‑Centering
A high cumulative radiation dose (3394 mGy.cm, 51 mSv) delivered by two acquisitions on the abdomen and pelvis and corresponding to more than 10 times the local median dose for this examination was retrospectively detected thanks to the Dose Archiving and Communicating System (DACS). Retrospective analysis of the examination showed that the cause of this high dose was an off‑centering of the patient—the table being in a too high position—disabling a correct diagnosis of an umbilical herniation that was visible on a repeated acquisition. Interestingly, the CTDIvol of the second acquisition was 40% lower than that of the first acquisition, a well‑known effect of off‑centering on automatic exposure control systems.
- 1 January 2025
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 109 (1) , 61
Open AccessRadiation Dose Alert: CT Overexposure As a Result of Patient Off‑Centering
A high cumulative radiation dose (3394 mGy.cm, 51 mSv) delivered by two acquisitions on the abdomen and pelvis and corresponding to more than 10 times the local median dose for this examination was retrospectively detected thanks to the Dose Archiving and Communicating System (DACS). Retrospective analysis of the examination showed that the cause of this high dose was an off‑centering of the patient—the table being in a too high position—disabling a correct diagnosis of an umbilical herniation that was visible on a repeated acquisition. Interestingly, the CTDIvol of the second acquisition was 40% lower than that of the first acquisition, a well‑known effect of off‑centering on automatic exposure control systems.
- Open Access
- 1 January 2025
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 109 (1) , 14
Aorto‑esophageal Fistula following Botox Injection
Aorto‑esophageal fistulas (AEF) are rare, often fatal connections between the thoracic aorta and esophagus, arising from aortic disease, esophageal conditions, or iatrogenic causes. Case: A 76‑year‑old woman, treated for esophageal nutcracker syndrome with endoscopic injection of botox, developed chest pain and esophageal hemorrhage. Computed tomography (CT) confirmed an AEF from an aortic pseudoaneurysm. She succumbed to circulatory collapse before treatment. Discussion: Endoscopic botox injections are a rare cause of AEF. The diagnosis relies on imaging and endoscopy, with surgery often required. Teaching point: Aorto‑esophageal fistulas are rare, life‑threatening complications, particularly after iatrogenic procedures. Early diagnosis is crucial, but prognosis remains poor.
- 1 January 2025
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 109 (1) , 14
Open AccessAorto‑esophageal Fistula following Botox Injection
Aorto‑esophageal fistulas (AEF) are rare, often fatal connections between the thoracic aorta and esophagus, arising from aortic disease, esophageal conditions, or iatrogenic causes. Case: A 76‑year‑old woman, treated for esophageal nutcracker syndrome with endoscopic injection of botox, developed chest pain and esophageal hemorrhage. Computed tomography (CT) confirmed an AEF from an aortic pseudoaneurysm. She succumbed to circulatory collapse before treatment. Discussion: Endoscopic botox injections are a rare cause of AEF. The diagnosis relies on imaging and endoscopy, with surgery often required. Teaching point: Aorto‑esophageal fistulas are rare, life‑threatening complications, particularly after iatrogenic procedures. Early diagnosis is crucial, but prognosis remains poor.
- Open Access
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 93
Tracheobronchial Diverticulosis
Teaching point: Tracheal diverticulosis is a rare and benign disorder, characterized by single or multiple tracheal wall outpouchings, either congenital or acquired, usually diagnosed incidentally on chest high‑resolution computed tomography, and in general remaining asymptomatic.
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 93
Open AccessTracheobronchial Diverticulosis
Teaching point: Tracheal diverticulosis is a rare and benign disorder, characterized by single or multiple tracheal wall outpouchings, either congenital or acquired, usually diagnosed incidentally on chest high‑resolution computed tomography, and in general remaining asymptomatic.
- Open Access
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 81
Mega Virchow–Robin
Teaching point: Perivascular spaces, also known as Virchow–Robin spaces, are fluid-filled spaces that surround the vessel walls from the subarachnoid space through the brain parenchyma.
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 81
Open AccessMega Virchow–Robin
Teaching point: Perivascular spaces, also known as Virchow–Robin spaces, are fluid-filled spaces that surround the vessel walls from the subarachnoid space through the brain parenchyma.
- Open Access
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 63
Unusual Air Crescents on Chest Radiographs
The air crescent (AC) is a common radiological sign. Even if its commonest aetiology remains pulmonary aspergillosis, various other causes have been described. In this study, we report four rare causes of ACs seen on chest radiographs that haven’t been described in the literature. Teaching point: The differential diagnosis of an air crescent sign on chest radiographs includes oesophageal bezoar, interstitial lung emphysema, central bronchial stenosis and perforated emphysematous cholecystitis.
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 63
Open AccessUnusual Air Crescents on Chest Radiographs
The air crescent (AC) is a common radiological sign. Even if its commonest aetiology remains pulmonary aspergillosis, various other causes have been described. In this study, we report four rare causes of ACs seen on chest radiographs that haven’t been described in the literature. Teaching point: The differential diagnosis of an air crescent sign on chest radiographs includes oesophageal bezoar, interstitial lung emphysema, central bronchial stenosis and perforated emphysematous cholecystitis.
- Open Access
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 44
Radiographic Detection of Post-Traumatic Bone Fractures: Contribution of Artificial Intelligence Software to the Analysis of Senior and Junior Radiologists
Objectives: The aims of this study were: (a) to evaluate the performance of an artificial intelligence (AI) software package (Boneview Trauma, Gleamer) for the detection of post-traumatic bone fractures in radiography as a standalone; (b) used by two radiologists (osteoarticular senior and junior); and (c) to determine to whom AI would be most helpful. Materials and Methods: Within 14 days of a trauma, 101 consecutive patients underwent radiographic examination of the upper or lower limbs. The definite diagnosis for identifying fractures was: (a) radio-clinical consensus between the radiologist on-call who analyzed the images and the orthopedist (Group 1); (b) Cone Beam computed tomography (CBCT) exploration of the area of interest, in case of doubts or absence of consensus (Group 2). Independently of this diagnosis for both groups, the radiographic images were separately analyzed by two radiologists (osteoarticular senior: SR; junior: JR) prior without, and thereafter with the results of AI. Results: AI performed better than the radiologists in detecting common fractures (Group 1), but not subtle fractures (Group 2). In association with AI, both radiologists increased their overall performances in both groups, whereas this increase was significantly higher for the JR (p < 0.05). Conclusion: AI is reliable for common radiographic fracture identification and is a useful learning tool for radiologists in training. However, the software’s overall performance does not exceed that of an osteoarticular senior radiologist, particularly in case of subtle lesions.
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 44
Open AccessRadiographic Detection of Post-Traumatic Bone Fractures: Contribution of Artificial Intelligence Software to the Analysis of Senior and Junior Radiologists
Objectives: The aims of this study were: (a) to evaluate the performance of an artificial intelligence (AI) software package (Boneview Trauma, Gleamer) for the detection of post-traumatic bone fractures in radiography as a standalone; (b) used by two radiologists (osteoarticular senior and junior); and (c) to determine to whom AI would be most helpful. Materials and Methods: Within 14 days of a trauma, 101 consecutive patients underwent radiographic examination of the upper or lower limbs. The definite diagnosis for identifying fractures was: (a) radio-clinical consensus between the radiologist on-call who analyzed the images and the orthopedist (Group 1); (b) Cone Beam computed tomography (CBCT) exploration of the area of interest, in case of doubts or absence of consensus (Group 2). Independently of this diagnosis for both groups, the radiographic images were separately analyzed by two radiologists (osteoarticular senior: SR; junior: JR) prior without, and thereafter with the results of AI. Results: AI performed better than the radiologists in detecting common fractures (Group 1), but not subtle fractures (Group 2). In association with AI, both radiologists increased their overall performances in both groups, whereas this increase was significantly higher for the JR (p < 0.05). Conclusion: AI is reliable for common radiographic fracture identification and is a useful learning tool for radiologists in training. However, the software’s overall performance does not exceed that of an osteoarticular senior radiologist, particularly in case of subtle lesions.
- Open Access
- 28 December 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 101
An Avoidable Cognitive Error in Chest Radiography
Teaching Point: Awareness in radiology reporting of cognitive errors such as the alliterative bias can help minimize the delay to diagnosis and accelerate adequate patient care.
- 28 December 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 101
Open AccessAn Avoidable Cognitive Error in Chest Radiography
Teaching Point: Awareness in radiology reporting of cognitive errors such as the alliterative bias can help minimize the delay to diagnosis and accelerate adequate patient care.
- Open Access
- 12 May 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 100
Reject Analysis in Digital Radiography and Computed Tomography: A Belgian Imaging Department Case Study
Objective: Reject analysis is usually performed in digital radiography (DR) for quality assurance. Data for computed tomography (CT) rejects remains sparse. The aim of this study is to help provide a straightforward benchmark for reject analysis of both DR and CT. Materials and methods: This retrospective observational study included 107,277 DR and 20,659 CT during 18 months in a tertiary care center. Rejected acquisitions were retrieved by Dose Archiving and Communication System (DACS). The DR and CT reject analysis included reject rates, reasons for rejection and supplementary radiation dose associated with these rejects. Results: 8,904 rejected DR and 514 rejected CT were retrieved. The DR reject rate was 8.3% whereas the CT reject rate was 2.5%. The cumulative effective dose (ED) of DR rejects was 377.3 mSv while the cumulative ED of CT rejects was 1267.4 mSv. The major reason for rejects was positioning for both DR (61%) and CT (44%). Conclusion: This study helps constitute a simple reproducible method to analyze both DR and CT rejects simultaneously. Although CT rejects are less often monitored than DR rejects, the radiation dose associated with CT rejects is much higher, which emphasizes the need to systematically monitor both DR and CT rejects. Investigating the reasons and the most frequently rejected examinations gives an opportunity for improvement of imaging techniques in cooperation with technologists.
- 12 May 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 100
Open AccessReject Analysis in Digital Radiography and Computed Tomography: A Belgian Imaging Department Case Study
Objective: Reject analysis is usually performed in digital radiography (DR) for quality assurance. Data for computed tomography (CT) rejects remains sparse. The aim of this study is to help provide a straightforward benchmark for reject analysis of both DR and CT. Materials and methods: This retrospective observational study included 107,277 DR and 20,659 CT during 18 months in a tertiary care center. Rejected acquisitions were retrieved by Dose Archiving and Communication System (DACS). The DR and CT reject analysis included reject rates, reasons for rejection and supplementary radiation dose associated with these rejects. Results: 8,904 rejected DR and 514 rejected CT were retrieved. The DR reject rate was 8.3% whereas the CT reject rate was 2.5%. The cumulative effective dose (ED) of DR rejects was 377.3 mSv while the cumulative ED of CT rejects was 1267.4 mSv. The major reason for rejects was positioning for both DR (61%) and CT (44%). Conclusion: This study helps constitute a simple reproducible method to analyze both DR and CT rejects simultaneously. Although CT rejects are less often monitored than DR rejects, the radiation dose associated with CT rejects is much higher, which emphasizes the need to systematically monitor both DR and CT rejects. Investigating the reasons and the most frequently rejected examinations gives an opportunity for improvement of imaging techniques in cooperation with technologists.
- Open Access
- 15 February 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 11
Central Pulmonary Embolism Detected on a Chest X-Ray: A Case Report
Patients presenting to the emergency room with respiratory symptoms often receive a chest X-ray as part of the initial workup to exclude common pathologies. A 60-year-old patient presented to the emergency department with dyspnoea. An initial chest X-ray revealed the Fleischner's sign, the knuckle sign, and the Westermark sign, specific but not sensitive for central pulmonary embolism, prompting a follow-up angio CT to confirm the diagnosis. The patient was treated and discharged a few days later. Chest X-rays, done as part of an initial workup, can show signs of pathologies that are not yet clinically suspected, such as pulmonary embolism.
- 15 February 2023
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 107 (1) , 11
Open AccessCentral Pulmonary Embolism Detected on a Chest X-Ray: A Case Report
Patients presenting to the emergency room with respiratory symptoms often receive a chest X-ray as part of the initial workup to exclude common pathologies. A 60-year-old patient presented to the emergency department with dyspnoea. An initial chest X-ray revealed the Fleischner's sign, the knuckle sign, and the Westermark sign, specific but not sensitive for central pulmonary embolism, prompting a follow-up angio CT to confirm the diagnosis. The patient was treated and discharged a few days later. Chest X-rays, done as part of an initial workup, can show signs of pathologies that are not yet clinically suspected, such as pulmonary embolism.